The best method for evaluating anteversion of the acetabular component after total hip arthroplasty on plain radiographs

被引:29
作者
Park, Yang Soo [1 ]
Shin, Won Chul [1 ]
Lee, Sang Min [1 ]
Kwak, Sang Ho [1 ]
Bae, Jung Yun [1 ]
Suh, Kuen Tak [1 ,2 ]
机构
[1] Pusan Natl Univ, Sch Med, Yangsan Hosp, Dept Orthoped, Yangsan, South Korea
[2] Pusan Natl Univ, Res Inst Convergence Biomed Sci & Technol, Dept Orthoped Surg, Yangsan Hosp,Sch Med, 20 Geumo Ro, Yangsan 626770, Gyeongsangnam D, South Korea
来源
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH | 2018年 / 13卷
关键词
Anteversion; Acetabular component; Plain radiograph; Total hip arthroplasty; MEASURING CUP ORIENTATION; POLYETHYLENE WEAR; ANTEROPOSTERIOR RADIOGRAPHS; INTRACLASS CORRELATIONS; LATERAL RADIOGRAPHS; RELIABILITY; REPLACEMENT; ACCURACY; POSITION; VERSION;
D O I
10.1186/s13018-018-0767-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Several radiological methods for measuring the anteversion of the acetabular component after total hip arthroplasty (THA) exist, and no single standardized method has been established. We evaluated the reliability and accuracy of six widely utilized methods (Liaw et al., Lewinnek et al., Widmer, Hassan et al., Ackland et al., and Woo and Morrey) for measuring anteversion on plain radiographs, using a reference standard in the same definition obtained from the PolyWare programme. Methods: We reviewed 71 patients who underwent primary unilateral THA. The anteversion of the acetabular component was measured on pelvis AP radiographs using five different methods (Liaw et al., Lewinnek et al., Widmer, Hassan et al., and Ackland et al.) and on cross-table lateral radiographs using the method of Woo and Morrey. The values obtained using the PolyWare programme, which determines the anteversion of the acetabular component by edge detection, were regarded as the reference standard. Results: Intra-and inter-observer reliabilities were excellent for all methods using plain radiographs, including the PolyWare programme. The method of Liaw et al. obtained values similar to those obtained using the PolyWare programme and was thus considered accurate (P = 0.447). However, values obtained using the other five methods significantly differed from those obtained using the PolyWare programme and were thus considered less accurate (P < 0.001, P < 0.001, P < 0.001, P = 0.007, and P < 0.001, respectively). Conclusion: The method of Liaw et al. is more accurate than other methods using plain radiographs for the measurement of the anteversion of the acetabular component after THA, with reference to the anteversion obtained from the PolyWare programme.
引用
收藏
页数:8
相关论文
共 35 条
  • [1] ANTEVERSION OF THE ACETABULAR CUP - MEASUREMENT OF ANGLE AFTER TOTAL HIP-REPLACEMENT
    ACKLAND, MK
    BOURNE, WB
    UHTHOFF, HK
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1986, 68 (03): : 409 - 413
  • [2] Difference between 2 measurement methods of version angles of the acetabular component
    Arai, Noriyuki
    Nakamura, Shigeru
    Matsushita, Takashi
    [J]. JOURNAL OF ARTHROPLASTY, 2007, 22 (05) : 715 - 720
  • [3] Biedermann R, 2005, J BONE JOINT SURG BR, V87B, P762, DOI 10.1302/0301-620X.87B6
  • [4] Sample size requirements for estimating intraclass correlations with desired precision
    Bonett, DG
    [J]. STATISTICS IN MEDICINE, 2002, 21 (09) : 1331 - 1335
  • [5] The John Charnley Award Risk Factors for Cup Malpositioning Quality Improvement Through a Joint Registry at a Tertiary Hospital
    Callanan, Mark C.
    Jarrett, Bryan
    Bragdon, Charles R.
    Zurakowski, David
    Rubash, Harry E.
    Freiberg, Andrew A.
    Malchau, Henrik
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (02) : 319 - 329
  • [6] CHARNLEY J, 1970, CLIN ORTHOP RELAT R, P7
  • [7] Measuring Acetabular Cup Orientation on Antero-Posterior Radiographs of the Hip after Total Hip Arthroplasty with a Vector Arithmetic Radiological Method. Is It Valid and Verified for Daily Clinical Practice?
    Craiovan, B.
    Weber, M.
    Worlicek, M.
    Schneider, M.
    Springorum, H. R.
    Zeman, F.
    Grifka, J.
    Renkawitz, T.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2016, 188 (06): : 574 - 581
  • [8] The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios
    D'Lima, DD
    Urquhart, AG
    Buehler, KO
    Walker, RH
    Colwell, CW
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (03) : 315 - 321
  • [9] Anterior dislocation of a total hip replacement. Radiographic and CT-scan assessment. Behavior following conservative management
    Di Schino, M.
    Baudart, F.
    Zilber, S.
    Poignard, A.
    Allain, J.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2009, 95 (08) : 573 - 578
  • [10] CT Outperforms Radiography for Determination of Acetabular Cup Version after THA
    Ghelman, Bernard
    Kepler, Christopher K.
    Lyman, Stephen
    Della Valle, Alejandro Gonzalez
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (09) : 2362 - 2370