Classroom energy efficiency and air environment with displacement natural ventilation in a passive public school building

被引:69
作者
Wang, Yang [1 ,2 ]
Zhao, Fu-Yun [3 ]
Kuckelkorn, Jens [1 ]
Liu, Di [4 ]
Liu, Jun [5 ]
Zhang, Jun-Liang [6 ]
机构
[1] Bavarian Ctr Appl Energy Res, Div Technol Energy Syst & Renewable Energy, D-85748 Garching, Bavaria, Germany
[2] Tech Univ Munich, Fac Mech Engn, Inst Energy Syst, D-85748 Munich, Bavaria, Germany
[3] Wuhan Univ, Sch Power & Mech Engn, Wuhan 430072, Hubei, Peoples R China
[4] China Univ Petr, Coll Pipeline & Civil Engn, Qingdao 266580, Shandong, Peoples R China
[5] Qingdao Univ Sci & Technol, Coll Automat & Elect Engn, Qingdao 266042, Shandong, Peoples R China
[6] Shandong Agr Univ, Coll Mech & Elect Engn, Tai An 271000, Shandong, Peoples R China
关键词
Displacement natural ventilation; Classroom air environment; Ventilation effectiveness; Computational fluid dynamics; Ventilation energy conservation; THERMAL COMFORT; PERFORMANCE; BUOYANCY; QUALITY; ROOM; WIND; HEAT; CONSUMPTION; TRANSPORTS; SYSTEMS;
D O I
10.1016/j.enbuild.2013.11.071
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Natural ventilation is an effective method to simultaneously improve indoor air quality and reduce energy consumption in buildings, especially when indoor temperature is close to ambient temperature e.g. the transitional seasons in Germany. Heat loss due to opened window and ventilation effectiveness ratio were analytically modeled. Following that, the effects of thermal buoyancy on the steady classroom airflow and thermal stratification comfort as well as the contaminant dispersion were discussed. Classroom displacement ventilation and its thermal stratification as well as indoor air quality indicated by the CO2 concentration have been investigated concerning the effects of supplying air temperature and delivering ventilation flow velocity. Representative thermal comfort parameters, percentage dissatisfied and temperature difference between ankle and head have been evaluated. Subsequent energy consumption efficiency analysis illuminates that classroom energy demands for natural ventilation not only in transitional seasons but also in winter could be decreased with the promotion of the ventilation effectiveness ratio for heat distribution when the natural ventilation rate maintains a constant, and with the shrinking of the ventilation effectiveness ratio for heat distribution when the supplying air temperature is not variable. Detailed fitting correlations of heat loss resulted from opened window and ventilation effectiveness of natural ventilation inside the classroom have been presented. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:258 / 270
页数:13
相关论文
共 49 条
  • [1] Design analysis of single-sided natural ventilation
    Allocca, C
    Chen, QY
    Glicksman, LR
    [J]. ENERGY AND BUILDINGS, 2003, 35 (08) : 785 - 795
  • [2] [Anonymous], KLIMAAUSWIRKLUNGEN A
  • [3] Energy efficient room air distribution
    Awbi, HB
    [J]. RENEWABLE ENERGY, 1998, 15 (1-4) : 293 - 299
  • [4] European residential buildings and empirical assessment of the Hellenic building stock, energy consumption, emissions and potential energy savings
    Balaras, Constantinos A.
    Gaglia, Athina G.
    Georgopoulou, Elena
    Mirasgedis, Sevastianos
    Sarafidis, Yiannis
    Lalas, Dimitris P.
    [J]. BUILDING AND ENVIRONMENT, 2007, 42 (03) : 1298 - 1314
  • [5] Energy thrift and thermal comfort in public houses
    Bond, MA
    Probert, SD
    [J]. APPLIED ENERGY, 1999, 62 (01) : 1 - 65
  • [6] Thermal comfort in naturally ventilated spaces and under indirect evaporative passive cooling conditions in hot-humid climate
    Bravo, Gaudy
    Gonzalez, Eduardo
    [J]. ENERGY AND BUILDINGS, 2013, 63 : 79 - 86
  • [7] Ventilation performance prediction for buildings: A method overview and recent applications
    Chen, Qingyan
    [J]. BUILDING AND ENVIRONMENT, 2009, 44 (04) : 848 - 858
  • [8] Experimental and numerical investigations on stratified air distribution systems with special configuration: Thermal comfort and energy saving
    Cheng, Yuanda
    Niu, Jianlei
    Liu, Xiaoping
    Gao, Naiping
    [J]. ENERGY AND BUILDINGS, 2013, 64 : 154 - 161
  • [9] Wind-induced indoor-air flow in a high-rise building adjacent to a vertical wall
    Chow, WK
    [J]. APPLIED ENERGY, 2004, 77 (02) : 225 - 234
  • [10] Cooling strategies, summer comfort and energy performance of a rehabilitated passive standard office building
    Eicker, Ursula