Direct analysis of coffee and tea for aluminium determination by electrothermal atomic absorption spectrometry

被引:17
|
作者
Magalhaes, CEC
Lima, ÉC
Krug, FJ
Arruda, MAZ
机构
[1] Univ Estadual Campinas, Inst Quim, BR-13083970 Campinas, SP, Brazil
[2] Univ Sao Paulo, Ctr Energia Nucl Agr, BR-13400970 Piracicaba, SP, Brazil
关键词
slurry atomization; aluminium; tea and coffee; ETAAS;
D O I
10.1007/s006040050048
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for direct analysis of tea and coffee samples by using electrothermal atomic absorption spectrometry is described. Coffee and tea from different sources were analyzed without digestion step. For slurry analyses the samples were ground, sieved at 105 mu m and then suspended in 0.2% v/v HNO3 and 10% v/v Triton X-100 medium. For liquid phase aluminium determination the samples were prepared in the same way and only the liquid is introduced directly into the graphite furnace. Calibration was performed by aqueous standards for both cases and the determinations were carried out in the linear range between 50 and 250 mu g L-1. The characteristic mass of aluminium and the detection limit were 45 pg and 2 mu g L-1, respectively. Using a typical 0.1% m/v coffee slurry sample, the relative standard deviation of measurements (n = 15) for repeatability was about 8.2%.
引用
收藏
页码:95 / 100
页数:6
相关论文
共 50 条
  • [21] Determination of Cd, Pb and As in sediments of the Sava River by electrothermal atomic absorption spectrometry
    Murko, Simona
    Milacic, Radmila
    Veber, Marjan
    Scancar, Janez
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2010, 75 (01) : 113 - 128
  • [22] Selective preconcentration and determination of tributyltin in fresh water by electrothermal atomic absorption spectrometry
    Bermejo-Barrera, P
    Anllo-Sendín, RM
    Cantelar-Barbazán, MJ
    Bermejo-Barrera, A
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 372 (7-8) : 837 - 839
  • [23] Palladium release in electrothermal atomic absorption spectrometry
    Slaveykova, VI
    Manev, SG
    Lazarov, DL
    SPECTROSCOPY LETTERS, 1997, 30 (02) : 297 - 307
  • [24] Adaptive Calibration in Electrothermal Atomic Absorption Spectrometry
    Sadagov, Yu. M.
    Sadagov, A. Yu.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2023, 78 (08) : 988 - 994
  • [25] Determination of cadmium by electrothermal atomic absorption spectrometry using electrochemical separation in a microcell
    Knápek, J
    Komárek, J
    Krásensky, P
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (03) : 393 - 398
  • [26] Slurry sampling for determination of lead in marine plankton by electrothermal atomic absorption spectrometry
    Arslan, Zikri
    Tyson, Julian F.
    MICROCHEMICAL JOURNAL, 2007, 86 (02) : 227 - 234
  • [27] Coprecipitation with disulfide for the determination of traces of cobalt in water by electrothermal atomic absorption spectrometry
    Hiraide, M
    Chen, ZS
    Kawaguchi, H
    TALANTA, 1996, 43 (07) : 1131 - 1136
  • [28] Modification of electrothermal atomic absorption spectrometry for determination of arsenic in high salinity samples
    Smolikova, Vendula
    Pelcova, Pavlina
    Hedbavny, Josef
    Zlamalova, Lucie
    Ridoskova, Andrea
    PROCEEDINGS OF 25TH INTERNATIONAL PHD STUDENTS CONFERENCE (MENDELNET 2018), 2018, : 527 - 531
  • [29] Direct determination of cadmium in solid biological materials by slurry sampling electrothermal atomic absorption spectrometry with polytetrafluoroethylene as a chemical modifier
    Wang, FY
    Jiang, ZC
    ANALYTICA CHIMICA ACTA, 1999, 391 (01) : 89 - 94
  • [30] Comparative study of chemical modifiers for the direct determination of chromium and nickel in polluted sea water by electrothermal atomic absorption spectrometry
    BermejoBarrera, P
    MoredaPineiro, J
    MoredaPineiro, A
    BermejoBarrera, A
    QUIMICA ANALITICA, 1996, 15 (03): : 249 - 254