Interchannel Mixing Minimization in Semi-Packed Micro Gas Chromatography Columns

被引:22
作者
Alfeeli, Bassam [1 ]
Narayanan, Shree [2 ]
Moodie, Daniel [2 ]
Zellner, Phillip [2 ]
McMillan, Mathew [3 ]
Hirtenstein, Daniel [3 ]
Rice, Gary [3 ]
Agah, Masoud [2 ]
机构
[1] Kuwait Inst Sci Res, Dept Adv Syst, Safat 13109, Kuwait
[2] Virginia Polytech Inst & State Univ, Dept Elect & Comp Engn, VTMEMS Lab, Blacksburg, VA 24061 USA
[3] Coll William & Mary, Dept Chem, Williamsburg, VA 23185 USA
基金
美国国家科学基金会;
关键词
Portable gas analyzers; micro total analysis systems; microfluidics; microfabricated separation columns; microelectromechanical systems; MICROFABRICATED COLUMNS; HIGH-PERFORMANCE; LIQUID-CHROMATOGRAPHY; SUPPORT STRUCTURES; MASS-TRANSFER; FABRICATION; DESIGN; PHASE; CHIP;
D O I
10.1109/JSEN.2013.2267795
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Semi-packed columns containing an array of micropillars embedded within an open rectangular column structure are a new class of micro gas chromatography (mu GC) columns introduced to provide higher separation efficiency and higher sample capacity. Three different semi-packed column configurations are evaluated with respect to pillar spacing along the flow direction and number of pillars across channel. The efficiencies of semi-packed columns, in terms of height-equivalent-to-a-theoretical-plate (HETP), are compared with two microfabricated open-rectangular columns. According to simulation results, arranging the pillars in a symmetrical configuration with spacing equal to the post dimension can suppress multi-path flows. Experimental results confirm the simulation prediction as the design with 2 mu m post spacing (SP1) demonstrates the highest performance among other designs. SP1 is found to have HETP of 0.010 cm (15 000 plates/m) at an optimal velocity of 18 cm/s. An open channel design with comparable channel width yields an HETP of 0.025 cm (6000 plates/m) at an optimal velocity of 45 cm/s. The pressure drop in semi-packed columns is experimentally measured to be similar to 9 kPa which falls within the practical range of microfabricated pumps.
引用
收藏
页码:4312 / 4319
页数:8
相关论文
共 37 条
[1]   High-performance temperature-programmed microfabricated gas chromatography columns [J].
Agah, M ;
Potkay, JA ;
Lambertus, G ;
Sacks, R ;
Wise, KD .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2005, 14 (05) :1039-1050
[2]   Low-mass PECVD oxynitride gas chromatographic columns [J].
Agah, Masoud ;
Wise, Kensall D. .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2007, 16 (04) :853-860
[3]   High-speed MEMS-based gas chromatography [J].
Agah, Masoud ;
Lambertus, Gordon Randall ;
Sacks, Richard ;
Wise, Kensall .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2006, 15 (05) :1371-1378
[4]   MEMS-based multi-inlet/outlet preconcentrator coated by inkjet printing of polymer adsorbents [J].
Alfeeli, Bassam ;
Cho, Daniel ;
Ashraf-Khorassani, Mehdi ;
Taylor, Larry T. ;
Agah, Masoud .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 133 (01) :24-32
[5]   MEMS-Based Selective Preconcentration of Trace Level Breath Analytes [J].
Alfeeli, Bassam ;
Agah, Masoud .
IEEE SENSORS JOURNAL, 2009, 9 (09) :1068-1075
[6]   MEMS-based semi-packed gas chromatography columns [J].
Ali, Syed ;
Ashraf-Khorassani, Mehdi ;
Taylor, Larry T. ;
Agah, Masoud .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 141 (01) :309-315
[7]  
[Anonymous], 2004, MODERN PRACTICE GAS, DOI DOI 10.1002/0471651141
[8]   Fabrication of micro-gas chromatograph columns for fast chromatography [J].
Bhushan, Abhinav ;
Yemane, Dawit ;
Trudell, Dan ;
Overton, Edward B. ;
Goettert, Jost .
MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2007, 13 (3-4) :361-368
[9]   Peak tailing and mass transfer kinetics in linear chromatography - Dependence on the column length and the linear velocity of the mobile phase [J].
Gotmar, G ;
Fornstedt, T ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 1999, 831 (01) :17-35
[10]  
Hanseup Kim, 2007, 2007 20th IEEE International Conference on Micro Electro Mechanical Systems - MEMS '07, P131, DOI 10.1109/MEMSYS.2007.4433033