Biotin dissolution from pharmaceutical dosage forms using an automated HPLC system

被引:4
作者
Aboul-Enein, HY
Hussein, RF
Radwan, MA
Al-Rawithi, S
机构
[1] King Faisal Specialist Hosp & Res Ctr, Dept Biol & Med Res, Pharmaceut Anal Lab, Riyadh 11211, Saudi Arabia
[2] King Faisal Specialist Hosp & Res Ctr, Dept Biol & Med Res, Pharmacokinet & Therapeut Drug Monitoring Lab, Riyadh 11211, Saudi Arabia
[3] King Saud Univ, Dept Women Students, Coll Pharm Sci & Med Studies, Dept Clin Pharm, Riyadh, Saudi Arabia
关键词
biotin; photodiode array detector; dissolution; HPLC;
D O I
10.1081/JLC-120027622
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel, rapid, accurate, and sensitive automated high-performance liquid chromatographic assay was developed to determine biotin (BI) in pharmaceutical dosage forms and to follow its dissolution pattern. An efficient separation of BI was performed using a stainless steel Supelcosil LC-18 column (25 cm x 4.6 mm; 5 mum particle size) preceded by a Sentry guard column. The mobile phase consisted of an 80% aqueous solution (pH 2.5 adjusted with phosphoric acid) containing 20% acetonitrile delivered at a flow rate of 1.5 mL/min. The compound of interest was detected using a photodiode array detector at 190 nm. Under these conditions, the assay run time was 6 min since the retention time of BI was 3.8 +/- 0.2 min. The detector response was linear for BI in alkaline solution (r > 0.999) in the range of 0.01-2.00 mug/mL. The detection and the quantification limits for BI were 0.005 and 0.01 mug/mL, respectively. The dissolution data showed RSD% of 3.6-12.7% for all BI determined concentrations. No interferences were observed from the tablet's excipients. The drug content in each tablet ranged from 100 to 102.5%. The dissolution study of BIOTIN(R) tablets revealed that BI in USP media (pH 1.2) showed no dissolution up to 3 hr. However, a first order release kinetic, with dissolution T-50% of 14 +/- 1.3 min, was observed in USP media (pH 7.4).
引用
收藏
页码:511 / 519
页数:9
相关论文
共 16 条
  • [1] BIOTIN IN HUMAN-NUTRITION
    BONJOUR, JP
    [J]. ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1985, 447 (JUN) : 97 - 104
  • [2] Liquid chromatographic determination of biotin in multivitamin-multimineral tablets
    Ekpe, AE
    Hazen, C
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 16 (08) : 1311 - 1315
  • [3] DETERMINATION OF FREE BIOTIN IN PLASMA BY LIQUID-CHROMATOGRAPHY WITH FLUOROMETRIC DETECTION
    HAYAKAWA, K
    OIZUMI, J
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 413 : 247 - 250
  • [4] Izumi Y, 1979, Methods Enzymol, V62, P326
  • [5] DETERMINATION OF BIOTIN IN MULTIVITAMIN PHARMACEUTICAL PREPARATIONS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    KAMATA, K
    HAGIWARA, T
    TAKAHASHI, M
    UEHARA, S
    NAKAYAMA, K
    AKIYAMA, K
    [J]. JOURNAL OF CHROMATOGRAPHY, 1986, 356 (02): : 326 - 330
  • [6] Analytical techniques for determining biotin
    Livaniou, E
    Costopoulou, D
    Vassiliadou, I
    Leondiadis, L
    Nyalala, JO
    Ithakissios, DS
    Evangelatos, GP
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 881 (1-2) : 331 - 343
  • [7] MOCK DM, 2001, HDB VITAMINS
  • [8] Fluorescence detection of biotin using post-column derivatization with OPA in high performance liquid chromatography
    Nojiri, S
    Kamata, K
    Nishijima, M
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 16 (08) : 1357 - 1362
  • [9] PEPPAS NA, 1985, PHARM ACTA HELV, V60, P110
  • [10] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF BIOTIN IN BIOLOGICAL-MATERIALS AFTER CROWN ETHER-CATALYZED FLUORESCENCE DERIVATIZATION WITH PANACYL BROMIDE
    STEIN, J
    HAHN, A
    LEMBCKE, B
    REHNER, G
    [J]. ANALYTICAL BIOCHEMISTRY, 1992, 200 (01) : 89 - 94