The Role of Patient-Specific Morphological Features of the Left Atrial Appendage on the Thromboembolic Risk Under Atrial Fibrillation

被引:19
作者
Musotto, Giulio [1 ,2 ]
Monteleone, Alessandra [1 ]
Vella, Danila [1 ]
Di Leonardo, Sofia [1 ]
Viola, Alessia [1 ,2 ]
Pitarresi, Giuseppe [2 ]
Zuccarello, Bernardo [2 ]
Pantano, Antonio [2 ]
Cook, Andrew [3 ,4 ]
Bosi, Giorgia M. [5 ]
Burriesci, Gaetano [1 ,5 ]
机构
[1] Ri MED Fdn, Bioengn Unit, Palermo, Italy
[2] Univ Palermo, Dept Engn, Palermo, Italy
[3] UCL Inst Cardiovasc Sci, London, England
[4] Great Ormond St Hosp Sick Children, London, England
[5] UCL, UCL Mech Engn, London, England
关键词
left atrial appendage; fluid-structure interaction; LAA morphology; patient-specific models; atrial fibrillation (AF); FLUID-STRUCTURE INTERACTION; THROMBUS FORMATION; P-WAVE; COMPUTATIONAL FRAMEWORK; BLOOD RHEOLOGY; STROKE; VOLUME; FLOW; MODELS; ECG;
D O I
10.3389/fcvm.2022.894187
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundA large majority of thrombi causing ischemic complications under atrial fibrillation (AF) originate in the left atrial appendage (LAA), an anatomical structure departing from the left atrium, characterized by a large morphological variability between individuals. This work analyses the hemodynamics simulated for different patient-specific models of LAA by means of computational fluid-structure interaction studies, modeling the effect of the changes in contractility and shape resulting from AF. MethodsThree operating conditions were analyzed: sinus rhythm, acute atrial fibrillation, and chronic atrial fibrillation. These were simulated on four patient-specific LAA morphologies, each associated with one of the main morphological variants identified from the common classification: chicken wing, cactus, windsock, and cauliflower. Active contractility of the wall muscle was calibrated on the basis of clinical evaluations of the filling and emptying volumes, and boundary conditions were imposed on the fluid to replicate physiological and pathological atrial pressures, typical of the various operating conditions. ResultsThe LAA volume and shear strain rates were analyzed over time and space for the different models. Globally, under AF conditions, all models were well aligned in terms of shear strain rate values and predicted levels of risk. Regions of low shear rate, typically associated with a higher risk of a clot, appeared to be promoted by sudden bends and focused at the trabecule and the lobes. These become substantially more pronounced and extended with AF, especially under acute conditions. ConclusionThis work clarifies the role of active and passive contraction on the healthy hemodynamics in the LAA, analyzing the hemodynamic effect of AF that promotes clot formation. The study indicates that local LAA topological features are more directly associated with a thromboembolic risk than the global shape of the appendage, suggesting that more effective classification criteria should be identified.
引用
收藏
页数:11
相关论文
共 51 条
[1]   Left atrial appendage: structure, function, and role in thromboembolism [J].
Al-Saady, NM ;
Obel, OA ;
Camm, AJ .
HEART, 1999, 82 (05) :547-554
[2]   Modeling of human blood rheology in transient shear flows [J].
Apostolidis, Alex J. ;
Armstrong, Matthew J. ;
Beris, Antony N. .
JOURNAL OF RHEOLOGY, 2015, 59 (01) :275-298
[3]   A Comparison of One-Way and Two-Way Coupling Methods for Numerical Analysis of Fluid-Structure Interactions [J].
Benra, Friedrich-Karl ;
Dohmen, Hans Josef ;
Pei, Ji ;
Schuster, Sebastian ;
Wan, Bo .
JOURNAL OF APPLIED MATHEMATICS, 2011,
[4]  
Berggren M, 2009, COMMUN COMPUT PHYS, V5, P456
[5]   Computational Fluid Dynamic Analysis of the Left Atrial Appendage to Predict Thrombosis Risk [J].
Bosi, Giorgia Maria ;
Cook, Andrew ;
Rai, Rajan ;
Menezes, Leon J. ;
Schievano, Silvia ;
Torii, Ryo ;
Burriesci, Gaetano .
FRONTIERS IN CARDIOVASCULAR MEDICINE, 2018, 5
[6]   An approach to the simulation of fluid-structure interaction in the aortic valve [J].
Carmody, CJ ;
Burriesci, G ;
Howard, IC ;
Patterson, EA .
JOURNAL OF BIOMECHANICS, 2006, 39 (01) :158-169
[7]   A high-order vertex-based central ENO finite-volume scheme for three-dimensional compressible flows [J].
Charest, Marc R. J. ;
Canfield, Thomas R. ;
Morgan, Nathaniel R. ;
Waltz, Jacob ;
Wohlbier, John G. .
COMPUTERS & FLUIDS, 2015, 114 :172-192
[8]   SHEAR DEPENDENCE OF EFFECTIVE CELL VOLUME AS A DETERMINANT OF BLOOD VISCOSITY [J].
CHIEN, S .
SCIENCE, 1970, 168 (3934) :977-&
[9]   ANSYS Workbench System Coupling: a state-of-the-art computational framework for analyzing multiphysics problems [J].
Chimakurthi, Satish Kumar ;
Reuss, Steve ;
Tooley, Michael ;
Scampoli, Stephen .
ENGINEERING WITH COMPUTERS, 2018, 34 (02) :385-411
[10]   Determination of a shear rate threshold for thrombus formation in intracranial aneurysms [J].
de Sousa, Daniel Ribeiro ;
Vallecilla, Carolina ;
Chodzynski, Kamil ;
Jerez, Ricardo Corredor ;
Malaspinas, Orestis ;
Eker, Omer Faruk ;
Ouared, Rafik ;
Vanhamme, Luc ;
Legrand, Alexandre ;
Chopard, Bastien ;
Courbebaisse, Guy ;
Boudjeltia, Karim Zouaoui .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (08) :853-858