Automated analysis of pleural fluid total and differential leukocyte counts with the Sysmex XE-2100

被引:42
作者
de Jonge, Robert
Brouwer, Rob
van Rijn, Marcel
van Acker, Bernadette A. C.
Otten, Henk J. A. M.
Lindemans, Jan
机构
[1] Erasmus Univ, Med Ctr, Dept Clin Chem, NL-3000 CA Rotterdam, Netherlands
[2] Erasmus Univ, Med Ctr, Dept Pulm Med, NL-3000 CA Rotterdam, Netherlands
关键词
cell counts; differential count; pleural fluid; Sysmex XE-2100;
D O I
10.1515/CCLM.2006.242
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Determination of leukocyte (WBC) counts in pleural fluid is routinely performed by microscopic examination. In this study, we evaluated the performance of automated (differential) WBC counting in comparison with manual counting. Methods: Pleural fluid samples (n=45) were obtained from patients undergoing diagnostic thoracocentesis. The manual total WBC count was determined after Samson staining in a Fuchs-Rosenthal hemocytometer; microscopic differential counts were performed on May-Grunwald Giemsa-stained cytospin slides. The Sysmex XE-2100 hematology analyzer was used for automated (differential) WBC counting. The functional detection limit was determined by serial dilution of continuous ambulatory peritoneal dialysis (CAPD) fluid and replicate measurements of each dilution. Results: The automated WBC count (x10(6)/L) was highly correlated with that of the microscopic reference method (r(2) =0.95; WBC-analyzer=0.97xWBC-reference method + 16; n = 45). Good agreement was also observed for the absolute lymphocyte count (r(2) = 0.92; WBC-analyzer=0.99xWBC-reference method+32; n = 36), neutrophil count (r(2) = 0.94; WBC-analyzer = 0.91 x WBC-reference method+6; n = 35), and monocyte count (r(2) = 0.73; WBC-analyzer = 0.83 x WBC-reference method + 6; n=38). The functional detection limit for WBCs was calculated at 50 x 10(6)/L (coefficient of variation 20%). Conclusions: With some limitations, total and differential WBC counts in pleural fluid can be reliably determined using the Sysmex XE-2100 instrument.
引用
收藏
页码:1367 / 1371
页数:5
相关论文
共 15 条
[1]  
Angeloni S, 2003, AM J GASTROENTEROL, V98, P1844, DOI 10.1111/j.1572-0241.2003.07620.x
[2]  
Aulesa C, 2003, Lab Hematol, V9, P214
[3]   Automated counting of white and red blood cells in the cerebrospinal fluid [J].
Aune, MW ;
Sandberg, S .
CLINICAL AND LABORATORY HAEMATOLOGY, 2000, 22 (04) :203-210
[4]   Automated flow cytometric analysis of blood cells in cerebrospinal fluid - Analytic performance [J].
Aune, MW ;
Becker, JL ;
Brugnara, C ;
Canfield, W ;
Dorfman, DM ;
Fiehn, W ;
Fischer, G ;
Fitzpatrick, P ;
Flaming, TH ;
Henriksen, HK ;
Kunicka, JE ;
Lackner, KJ ;
Minchello, E ;
Mullenix, PA ;
Myers, M ;
Petersen, A ;
Ternstrom, W ;
Wilson, S .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2004, 121 (05) :690-700
[5]   BTS guidelines for the management of pleural infection in children [J].
Balfour-Lynn, IM ;
Abrahamson, E ;
Cohen, G ;
Hartley, J ;
King, S ;
Parikh, D ;
Spencer, D ;
Thomson, AH ;
Urquhart, D .
THORAX, 2005, 60 :1-21
[6]   Variations in pleural fluid WBC count and differential counts with different sample containers and different methods [J].
Conner, BD ;
Lee, YCG ;
Branca, P ;
Rogers, JT ;
Rodriguez, RM ;
Light, RW .
CHEST, 2003, 123 (04) :1181-1187
[7]   Automated counting of white blood cells in synovial fluid [J].
de Jonge, R ;
Brouwer, R ;
Smit, M ;
de Frankrijker-Merkestijn, M ;
Dolhain, RJEM ;
Hazes, JMW ;
van Toorenenbergen, AW ;
Lindemans, J .
RHEUMATOLOGY, 2004, 43 (02) :170-173
[8]   Automated Counting of Cells in Cerebrospinal Fluid Using the CellDyn-4000 Haematology Analyser [J].
Hoffmann, Johannes J. M. L. ;
Janssen, Willy C. M. .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2002, 40 (11) :1168-1173
[9]  
Kresie Lesley, 2005, Lab Hematol, V11, P24, DOI 10.1532/LH96.04067
[10]   CELLS IN PLEURAL FLUID - THEIR VALUE IN DIFFERENTIAL DIAGNOSIS [J].
LIGHT, RW ;
EROZAN, YS ;
BALL, WC .
ARCHIVES OF INTERNAL MEDICINE, 1973, 132 (06) :854-860