Artificial human corneas - Scaffolds for transplantation and host regeneration

被引:74
作者
Griffith, M
Hakim, M
Shimmura, S
Watsky, MA
Li, FF
Carlsson, D
Doillon, CJ
Nakamura, M
Suuronen, E
Shinozaki, N
Nakata, K
Sheardown, H
机构
[1] Univ Ottawa, Inst Eye, Ottawa, ON K1N 6N5, Canada
[2] Natl Res Council Canada, ICPET, Ottawa, ON K1A 0R6, Canada
[3] Ichikawa Gen Hosp, Cornea Ctr, Tokyo Dent Coll, Ichikawa, Chiba, Japan
[4] Univ Tennessee, Ctr Hlth Sci, Dept Physiol, Memphis, TN 38163 USA
[5] Univ Laval, Oncol & Mol Endocrinol Res Ctr, Quebec City, PQ G1K 7P4, Canada
[6] Santen Pharmaceut Co Ltd, Nara R&D Ctr, Ikoma, Nara, Japan
[7] McMaster Univ, Dept Chem Engn, Hamilton, ON L8S 4L8, Canada
关键词
artificial corneas; keratoprostheses; polymers; tissue engineering; tissue equivalents; transplantation;
D O I
10.1097/01.ico.0000263120.68768.f8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To review the development of artificial corneas (prostheses and tissue equivalents) for transplantation, and to provide recent updates on our tissue-engineered replacement corneas. Methods. Modified natural polymers and synthetic polymers were screened for their potential to replace damaged portions of the human cornea or the entire corneal thickness. These polymers, combined with cells derived from each of the three main corneal layers or stem cells, were used to develop artificial corneas. Functional testing was performed in vitro. Trials of biocompatibility and immune and inflammatory reactions were performed by implanting the most promising polymers into rabbit corneas. Results. Collagen-based biopolymers, combined with synthetic crosslinkers or copolymers, formed effective scaffolds for developing prototype artificial corneas that could be used as tissue replacements in the future. We have previously developed an artificial cornea that mimicked key morphologic and functional properties of the human cornea. The addition of synthetic polymers increased its toughness as it retained transparency and low light scattering, making the matrix scaffold more suitable for transplantation. These new composites were implanted into rabbits without causing any acute inflammation or immune response. We have also fabricated full-thickness composites that can be fully sutured. However, the long-term effects of these artificial corneas need to be evaluated. Conclusions. Novel tissue-engineered corneas that comprise composites of natural and synthetic biopolymers together with corneal cell lines or stem cells will, in the future, replace portions of the cornea that are damaged. Our results provide a basis for the development of both implantable temporary and permanent corneal replacements.
引用
收藏
页码:S54 / S61
页数:8
相关论文
共 42 条
  • [31] A human vascular endothelial cell model to study angiogenesis and tumorigenesis
    Rhim, JS
    Tsai, WP
    Chen, ZQ
    Chen, Z
    Van Waes, C
    Burger, AM
    Lautenberger, JA
    [J]. CARCINOGENESIS, 1998, 19 (04) : 673 - 681
  • [32] RIDLEY NHL, 1996, BIOMATERIALS SCI INT, P435
  • [33] Sweeney DF, 1998, INVEST OPHTH VIS SCI, V39, P284
  • [34] Thompson K P, 1991, Refract Corneal Surg, V7, P240
  • [35] Biological response to a synthetic cornea
    Trinkaus-Randall, V
    Nugent, MA
    [J]. JOURNAL OF CONTROLLED RELEASE, 1998, 53 (1-3) : 205 - 214
  • [36] TRINKAUSRANDALL V, 1988, INVEST OPHTH VIS SCI, V29, P393
  • [37] Calcification of poly(2-hydroxyethyl methacrylate) hydrogel sponges implanted in the rabbit cornea: A 3-month study
    Vijayasekaran, S
    Chirila, TV
    Robertson, TA
    Lou, X
    Fitton, JH
    Hicks, CR
    Constable, IJ
    [J]. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2000, 11 (06) : 599 - 615
  • [38] WATSKY MA, 1992, J MEMBRANE BIOL, V128, P123
  • [39] EVALUATION OF COLLAGEN CROSSLINKING TECHNIQUES
    WEADOCK, K
    OLSON, RM
    SILVER, FH
    [J]. BIOMATERIALS MEDICAL DEVICES AND ARTIFICIAL ORGANS, 1983, 11 (04): : 293 - 318
  • [40] In vivo comparison of three different porous materials intended for use in a keratoprosthesis
    Wu, XY
    Tsuk, A
    Leibowitz, HM
    Trinkaus-Randall, V
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1998, 82 (05) : 569 - 576