Vessel extraction from non-fluorescein fundus images using orientation-aware detector

被引:81
作者
Yin, Benjun [1 ]
Li, Huating [2 ]
Sheng, Bin [1 ]
Hou, Xuhong [2 ]
Chen, Yan [3 ]
Wu, Wen [4 ]
Li, Ping [5 ]
Shen, Ruimin [1 ]
Bao, Yuqian [2 ]
Jia, Weiping [2 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Comp Sci & Engn, Shanghai 200240, Peoples R China
[2] Shanghai Jiao Tong Univ, Affiliated Peoples Hosp 6, Dept Endocrinol & Metab,Shanghai Key Clin Ctr Met, Shanghai Clin Ctr Diabet,Shanghai Diabet Inst,Sha, Shanghai 200240, Peoples R China
[3] Shanghai Jiao Tong Univ, Affiliated Peoples Hosp 6, Dept Ophthalmol, Shanghai 200240, Peoples R China
[4] Univ Macau, Fac Sci & Technol, Dept Comp & Informat Sci, Taipa, Peoples R China
[5] Hong Kong Inst Educ, Dept Math & Informat Technol, Hong Kong, Hong Kong, Peoples R China
关键词
Vessel extraction; Fundus image; Gabor wavelet; Line operator; Path opening; RETINAL BLOOD-VESSELS; MATCHED-FILTER; MATHEMATICAL MORPHOLOGY; SEGMENTATION; WAVELET;
D O I
10.1016/j.media.2015.09.002
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The automatic extraction of blood vessels in non-fluorescein eye fundus images is a tough task in applications such as diabetic retinopathy screening. However, vessel shapes have complex variations, and accurate modeling of retinal vascular structures is challenging. We have therefore developed a new approach to accurately extract blood vessels in non-fluorescein fundus images using an orientation-aware detector (OAD). The detector was designed according to the intrinsic property of vessels being locally oriented and having linearly elongated structures. We employ the OAD to extract vessel shapes with no assumptions on parametric orientations of vessel shapes. The orientations of vessels can be efficiently modeled by the energy distribution of Fourier transformation. Accordingly, both wide and thin vessels can be extracted with two-scale segmentation in which line operators are applied in large scale and the Gabor filter bank is applied in small scale. A post-processing technique, based on the path opening operation, is applied to eliminate false responses to nonvascular areas, such as retinal structures (optic disc and macula) and pathologies (exudates, hemorrhages,and microaneurysms). This makes the detector robust and structure-aware. By achieving a competitive CAL measurement of 80.82% for the DRIVE database and 68.94% for the STARE, the experimental results demonstrated that the OAD approach outperforms existing segmentation methods. Furthermore, the proposed approach effectively works with non-fluorescein fundus images and proves highly accurate and robust in complicated regions such as the central reflex, close vessels, and crossover points, despite a high level of illumination noise in the original data. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:232 / 242
页数:11
相关论文
共 42 条
  • [1] An improved matched filter for blood vessel detection of digital retinal images
    Al-Rawi, Mohammed
    Qutaishat, Munib
    Arrar, Mohammed
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2007, 37 (02) : 262 - 267
  • [2] A wavelet-based method for multifractal image analysis.: I.: Methodology and test applications on isotropic and anisotropic random rough surfaces
    Arnédo, A
    Decoster, N
    Roux, SG
    [J]. EUROPEAN PHYSICAL JOURNAL B, 2000, 15 (03) : 567 - 600
  • [3] A Multi-Orientation Analysis Approach to Retinal Vessel Tracking
    Bekkers, Erik
    Duits, Remco
    Berendschot, Tos
    Romeny, Bart ter Haar
    [J]. JOURNAL OF MATHEMATICAL IMAGING AND VISION, 2014, 49 (03) : 583 - 610
  • [4] Buckley M., 2000, FLEXIBLE LINEAR OPEN, P109
  • [5] DETECTION OF BLOOD-VESSELS IN RETINAL IMAGES USING TWO-DIMENSIONAL MATCHED-FILTERS
    CHAUDHURI, S
    CHATTERJEE, S
    KATZ, N
    NELSON, M
    GOLDBAUM, M
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1989, 8 (03) : 263 - 269
  • [6] Chutatape O, 1998, P ANN INT IEEE EMBS, V20, P3144, DOI 10.1109/IEMBS.1998.746160
  • [7] A Function for Quality Evaluation of Retinal Vessel Segmentations
    Emilio Gegundez-Arias, Manuel
    Aquino, Arturo
    Manuel Bravo, Jose
    Marin, Diego
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (02) : 231 - 239
  • [8] Espona L, 2008, INT C PATT RECOG, P2128
  • [9] Detection and measurement of retinal vessels, in fundus images using amplitude modified second-order Gaussian filter
    Gang, L
    Chutatape, O
    Krishnan, SM
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (02) : 168 - 172
  • [10] Path openings and closings
    Heijmans, H
    [J]. JOURNAL OF MATHEMATICAL IMAGING AND VISION, 2005, 22 (2-3) : 107 - 119