Quality of nuchal translucency measurements in The Netherlands: a quantitative analysis

被引:20
作者
Koster, M. P. H. [1 ,2 ]
Wortelboer, E. J. [2 ]
Engels, M. A. J. [3 ]
Stoutenbeek, P. H. [2 ]
Elvers, L. H. [1 ]
Visser, G. H. A. [2 ]
Schielen, P. C. J. I. [1 ]
机构
[1] Natl Inst Publ Hlth & Environm RIVM, Diagnost Lab Infect Dis & Perinatal Screening, NL-3720 BA Bilthoven, Netherlands
[2] Univ Med Ctr Utrecht, Div Perinatol & Gynaecol, Utrecht, Netherlands
[3] Free Univ Amsterdam, Med Ctr Amsterdam VUMC, Div Perinatol & Gynaecol, Amsterdam, Netherlands
关键词
Down syndrome; nuchal translucency; prenatal screening; quality assurance; DOWN-SYNDROME; DELTA-NT; ULTRASOUND; 1ST-TRIMESTER; MULTICENTER; THICKNESS; MEDIANS;
D O I
10.1002/uog.6398
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective The Dutch Centre for Population Research has specified quality demands for nuchal translucency (NT) measurement in The Netherlands. We performed an analysis of the quality of NT measurement in 2005-2006 and its influence on screening performance. Methods This was a retrospective study of records of NT measurements (n = 27738) obtained between January 2005 and December 2006 retrieved from the Dutch National Institute for Public Health and the Environment (RIVM). The performance of each individual operator was analyzed with regard to the quality standards, which involved calculation of operator-specific median NT-multiples of the median (MoM) values. For the entire population of operators, a curve was determined describing the relationship between crown-rump length and NT. Detection rates (DR) and false-positive rates (FPR) for Down syndrome were modeled with this new curve and compared to those originally obtained using previously published reference data. Results Only 22% of all operators met the quality requirement of performing more than 150 NT measurements per year. However, no relationship teas found between the number of measurements per operator and their median NT-MoM. The mean of all operator-specific median NT-MoM values was 0.94 (target value 1.0). Overall, operators with The Fetal Medicine Foundation certificate measured a significantly higher median NT-MoM (mean of operator-specific medians, 0.98) as compared to the non-certified operators (0.92). During the study period, the monthly median NT-MoM of all operators rose steadily, from 0.86 in January 2005 to 0.96 in December 2006. Recalculation of the risk for Dozen syndrome after adjusting the reference NT medians using our own data led to a modeled 4% increase in DR at a 5% FPR. Conclusion Improved monitoring of NT measurement put into effect during the study period seems to have led to an improvement in the accuracy of measurements. Strict quality demands, continued monitoring and scrupulous evaluation of individual operators is likely to lead to an even better performance. Copyright (C) 2009 ISUOG. Published by John Wiley & Sons, Ltd.
引用
收藏
页码:136 / 141
页数:6
相关论文
共 50 条
  • [1] The CUSUM test applied in prospective nuchal translucency quality review
    Sabria, J.
    Barcelo-Vidal, C.
    Arigita, M.
    Jimenez, J. M.
    Puerto, B.
    Borrell, A.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2011, 37 (05) : 582 - 587
  • [2] Likelihood ratio-based quality control for nuchal translucency measurements at 11-14 weeks of gestation
    Salomon, L. J.
    Porcher, R.
    Stirnemann, J. J.
    Bernard, J. P.
    Ville, Y.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2011, 37 (05) : 576 - 581
  • [3] Quality of nuchal translucency measurements in multifetal pregnancies
    Zohav, Efraim
    Segal, Octav
    Rabinson, Jacob
    Meltcer, Simion
    Anteby, Eyal Y.
    Orvieto, Raoul
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2006, 19 (10) : 663 - 666
  • [4] Evaluation of a proximity training program of nuchal translucency measurements and of self-scoring
    Bresson, L.
    Devos, P.
    Maillet, A.
    Verbecq, P.
    Ardaens, Y.
    Dalage, B.
    Bourgeot, P.
    Herbeau, D.
    Valat, A. -S.
    Robert, Y.
    Vaast, P.
    Houfflin-Debarge, V.
    Subtil, D.
    JOURNAL DE GYNECOLOGIE OBSTETRIQUE ET BIOLOGIE DE LA REPRODUCTION, 2010, 39 (05): : 379 - 386
  • [5] Quality assessment of routine nuchal translucency measurements: a North American laboratory perspective
    Palomaki, Glenn E.
    Neveux, Louis M.
    Donnenfeld, Alan
    Lee, Jo Ellen S.
    McDowell, Geraldine
    Canick, Jacob A.
    Summers, Anne
    Lambert-Messerlian, Geralyn
    Kellner, Leonard H.
    Zebelman, Arthur
    Haddow, James E.
    GENETICS IN MEDICINE, 2008, 10 (02) : 131 - 138
  • [6] Monitoring Quality Control of Nuchal Translucency
    Cuckle, Howard
    CLINICS IN LABORATORY MEDICINE, 2010, 30 (03) : 593 - +
  • [7] Analysis of Quality of Nuchal Translucency Measurements: Its Role in Prenatal Diagnosis
    Comas Gabriel, Carmen
    Echevarria, M.
    Rodriguez, I.
    Serra, B.
    SCIENTIFIC WORLD JOURNAL, 2012,
  • [8] The effects of maternal and fetal parameters on the quality of nuchal translucency measurement
    Zohav, E
    Dunsky, A
    Segal, O
    Peled, R
    Herman, A
    Segal, S
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2001, 18 (06) : 638 - 640
  • [9] Correlation, between nuchal translucency and nuchal skin-fold measurements in Down syndrome and unaffected fetuses
    Maymon, R.
    Zimerman, A. L.
    Weinraub, Z.
    Herman, A.
    Cuckle, H.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2008, 32 (04) : 501 - 505
  • [10] Nuchal translucency measurement: are qualitative and quantitative quality control processes related?
    Hermann, Monika
    Fries, Nicolas
    Mangione, Raphaelle
    Boukobza, Philippe
    Ville, Yves
    Salomon, Laurent J.
    PRENATAL DIAGNOSIS, 2013, 33 (08) : 770 - 774