Biomechanical analysis of plate systems for proximal humerus fractures: a systematic literature review

被引:46
作者
Jabran, Ali [1 ]
Peach, Chris [1 ,2 ]
Ren, Lei [1 ]
机构
[1] Univ Manchester, Sch Mech Aerosp & Civil Engn, Manchester, Lancs, England
[2] Univ Hosp South Manchester, Dept Shoulder & Elbow Surg, Manchester, Lancs, England
来源
BIOMEDICAL ENGINEERING ONLINE | 2018年 / 17卷
基金
英国工程与自然科学研究理事会;
关键词
Proximal humerus fractures; Locking plates; Open reduction internal fixation; Biomechanical testing; SURGICAL NECK FRACTURES; INTRAMEDULLARY FIBULAR ALLOGRAFT; CALCIUM-PHOSPHATE CEMENT; HUMAN SHOULDER SPECIMENS; MEDIAL CORTICAL SUPPORT; FINITE-ELEMENT-ANALYSIS; ANGULAR STABLE PLATE; ROTATOR CUFF SUTURES; IN-VITRO ASSESSMENT; LOCKING PLATE;
D O I
10.1186/s12938-018-0479-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Proximal humerus fractures are the third most common in the human body but their management remains controversial. Open reduction and internal fixation with plates is one of the leading modes of operative treatment for these fractures. The development of technologies and techniques for these plates, during the recent decades, promise a bright future for their clinical use. A comprehensive review of in vitro biomechanical studies is needed for the comparison of plates' mechanical performance and the testing methodologies. This will not only guide clinicians with plate selection but also with the design of future in vitro biomechanical studies. This review was aimed to systematically categorise and review the in vitro biomechanical studies of these plates based on their protocols and discuss their results. The technologies and techniques investigated in these studies were categorised and compared to reach a census where possible. Methods and results: Web of Science and Scopus database search yielded 62 studies. Out of these, 51 performed axial loading, torsion, bending and/or combined bending and axial loading while 11 simulated complex glenohumeral movements by using tendons. Loading conditions and set-up, failure criteria and performance parameters, as well as results for each study, were reviewed. Only two studies tested four-part fracture model while the rest investigated two-and three-part fractures. In ten studies, synthetic humeri were tested instead of cadaveric ones. In addition to load-displacement data, three-dimensional motion analysis systems, digital image correlation and acoustic emission testing have been used for measurement. Conclusions: Overall, PHILOS was the most tested plate and locking plates demonstrated better mechanical performance than non-locking ones. Conflicting results have been published for their comparison with non-locking blade plates and polyaxial locking screws. Augmentation with cement [calcium phosphate or poly(methyl methacrylate)] or allografts (fibular and femoral head) was found to improve bone-plate constructs' mechanical performance. Controversy still lies over the use of rigid and semi-rigid implants and the insertion of inferomedial screws for calcar region support. This review will guide the design of in vitro and in silico biomechanical tests and also supplement the study of clinical literature.
引用
收藏
页数:30
相关论文
共 126 条
  • [91] Mechanical Assessment of Local Bone Quality to Predict Failure of Locked Plating in a Proximal Humerus Fracture Model
    Roederer, Goetz
    Brianza, Stefano
    Schiuma, Damiano
    Schwyn, Ronald
    Scola, Alexander
    Gueorguiev, Boyko
    Gebhard, Florian
    Tami, Andrea
    [J]. ORTHOPEDICS, 2013, 36 (09) : E1134 - E1140
  • [92] Biomechanical in vitro assessment of screw augmentation in locked plating of proximal humerus fractures
    Roederer, Goetz
    Scola, Alexander
    Schmoelz, Werner
    Gebhard, Florian
    Windolf, Markus
    Hofmann-Fliri, Ladina
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (10): : 1327 - 1332
  • [93] Biomechanical in vitro assessment of fixed angle plating using a new concept of locking for the treatment of osteoporotic proximal humerus fractures
    Roederer, Goetz
    Gebhard, Florian
    Krischak, Gert
    Wilke, Hans-Joachim
    Claes, Lutz
    [J]. INTERNATIONAL ORTHOPAEDICS, 2011, 35 (04) : 535 - 541
  • [94] Regarding "Proximal humeral fracture fixation: a biomechanical comparison of two constructs"
    Rose, David M.
    Gupta, Rohit R.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2013, 22 (09) : E20 - E20
  • [95] Proximal Humeral Fractures: A Biomechanical Comparison of Locking Plate Constructs in a Cadaveric 3-Part Fracture Model
    Rose, David M.
    Sutter, Edward G.
    Mears, Simon C.
    Gupta, Rohit R.
    Belkoff, Stephen M.
    [J]. GERIATRIC ORTHOPAEDIC SURGERY & REHABILITATION, 2010, 1 (02) : 73 - 77
  • [96] Percutaneous pinning of the proximal part of the humerus - An anatomic study
    Rowles, DJ
    McGrory, JE
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (11) : 1695 - 1699
  • [97] Fixation of three-part proximal humeral fractures: A biomechanical evaluation
    Ruch, DS
    Glisson, RR
    Marr, AW
    Russell, GB
    Nunley, JA
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2000, 14 (01) : 36 - 40
  • [98] Biomechanical evaluation of locked plating in proximal humeral fractures
    Sanders, Brett S.
    Bullington, Andrew B.
    McGillivary, Gary R.
    Hutton, William C.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2007, 16 (02) : 229 - 234
  • [99] SchindeleS, 1999, Swiss Surg, V5, P281, DOI 10.1024/1023-9332.5.6.281
  • [100] PEEK versus titanium locking plates for proximal humerus fracture fixation: a comparative biomechanical study in two- and three-part fractures
    Schliemann, Benedikt
    Seifert, Robert
    Theisen, Christina
    Gehweiler, Dominic
    Wahnert, Dirk
    Schulze, Martin
    Raschke, Michael J.
    Weimann, Andre
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (01) : 63 - 71