Y-stent assisted coiling of bifurcation aneurysms with Enterprise stent: long-term follow-up

被引:48
|
作者
Limbucci, Nicola [1 ]
Renieri, Leonardo [1 ]
Nappini, Sergio [1 ]
Consoli, Arturo [1 ]
Rosi, Andrea [1 ]
Mangiafico, Salvatore [1 ]
机构
[1] Careggi Univ Hosp, Intervent Neuroradiol Unit, Florence, Italy
关键词
BASILAR TIP ANEURYSMS; SINGLE-CENTER EXPERIENCE; ENDOVASCULAR TREATMENT; INTRACRANIAL ANEURYSMS; CEREBRAL ANEURYSMS; EMBOLIZATION; CONFIGURATION; PLACEMENT; DEVICE; ARTERY;
D O I
10.1136/neurintsurg-2014-011483
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Background Y-stent assisted coiling has been proposed for the treatment of wide-neck bifurcation aneurysms, but there are many technical variations. We report our single-center experience of Y-stent assisted coiling of bifurcation aneurysms with the closed cell Enterprise stent in order to evaluate the safety and long-term results of this technique. The literature on Y-stenting and its hemodynamic effects are reviewed. Methods Fifty-two consecutive patients with wide-neck bifurcation aneurysms underwent Y-stent assisted coiling with two Enterprise stents. The procedure was completed in 48 cases (92.3%) and technical failure occurred in 4 cases (7.3%). Cases performed with other stents were excluded. All procedures were performed under double antiplatelet therapy. Periodic clinical and neuroradiological follow-up was performed. Results Mean neuroradiological follow-up time was 26 months. Complete immediate occlusion was obtained in 87.5% of patients. Two remnants had regrown at follow-up and were recoiled, achieving complete occlusion. The late neuroradiological occlusion rate was: complete occlusion 93.6%, neck remnant 4.3%, sac remnant 2.1%. No in-stent stenosis was detected at follow-up. Among the 48 procedures, two complications occurred (4.2%). Mortality was 2.1%. No delayed ischemic stroke occurred. Conclusions Y-stent assisted coiling has a high immediate occlusion rate and very good long-term stability. The procedure is relatively safe, although the complication and mortality rates are not negligible. Two Enterprise stents can be safely used for Y-stenting and, indeed, offer the advantage of easier catheterization, delivery and deployment into distal and tortuous vessels than open cell stents.
引用
收藏
页码:158 / 162
页数:5
相关论文
共 50 条
  • [21] Long-term outcomes of wide-necked intracranial bifurcation aneurysms treated with T-stent-assisted coiling
    Aydin, Kubilay
    Stracke, Christian Paul
    Barburoglu, Mehmet
    Yamac, Elif
    Berdikhojayev, Mynzhylky
    Sencer, Serra
    Chapot, Rene
    JOURNAL OF NEUROSURGERY, 2021, 134 (01) : 39 - 48
  • [22] CE-MRA for Follow-up of Aneurysms Post Stent-Assisted Coiling
    Agid, R.
    Schaaf, M.
    Farb, Ri.
    INTERVENTIONAL NEURORADIOLOGY, 2012, 18 (03) : 275 - 283
  • [23] The hemodynamic alterations induced by the vascular angular deformation in stent-assisted coiling of bifurcation aneurysms
    Jeong, W.
    Han, M. H.
    Rhee, K.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2014, 53 : 1 - 8
  • [24] Factors predicting recanalization following stent-assisted coil embolization of unruptured intracranial aneurysms with long-term follow-up
    Won, Yu Deok
    Kim, Young Deok
    Ban, Seung Pil
    Kwon, O-Ki
    FRONTIERS IN NEUROLOGY, 2024, 15
  • [25] Neuroform stent-assisted treatment of intracranial aneurysms: long-term follow-up study of aneurysm recurrence and in-stent stenosis rates
    Kulcsar, Zsolt
    Goericke, Sophia L.
    Gizewski, Elke R.
    Schlamann, Marc
    Sure, Ulrich
    Sandalcioglu, I. Erol
    Ladd, Susanne
    Mummel, Petra
    Kastrup, Oliver
    Forsting, Michael
    Wanke, Isabel
    NEURORADIOLOGY, 2013, 55 (04) : 459 - 465
  • [26] Comparison between Solitaire™ AB and Enterprise stent-assisted coiling for intracranial aneurysms
    Ye, Hua-Wei
    Liu, Ya-Qi
    Wang, Qiu-Jing
    Zheng, Tao
    Cui, Xu-Bo
    Gao, Yu-Yuan
    Lai, Ling-Feng
    Zhang, Xin
    Li, Xi-Feng
    Su, Shi-Xing
    He, Xu-Ying
    Duan, Chuan-Zhi
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2015, 10 (01) : 145 - 153
  • [27] Will Fluoroscopic Follow-up after Stent-Assisted Coiling of Cerebral Aneurysms Provide Information on Recanalization?
    Oh, Hyun Ho
    Jung, Cheolkyu
    Lee, Tae Hong
    Kwon, Bae Ju
    Kim, Young
    Lee, Kyu Chang
    INTERVENTIONAL NEURORADIOLOGY, 2014, 20 (06) : 693 - 703
  • [28] Comparison of Recanalization and In-Stent Stenosis Between the Low-Profile Visualized Intraluminal Support Stent and Enterprise Stent-Assisted Coiling for 254 Intracranial Aneurysms
    Feng, Xin
    Qian, Zenghui
    Liu, Peng
    Zhang, Baorui
    Wang, Luyao
    Guo, Erkang
    Wen, Xiaolong
    Xu, Wenjuan
    Jiang, Chuhan
    Wu, Zhongxue
    Li, Youxiang
    Liu, Aihua
    WORLD NEUROSURGERY, 2018, 109 : E99 - E104
  • [29] Stent-assisted coiling of cerebral aneurysms using the Enterprise and the Solitaire devices
    Chen, Yong-An
    Hussain, Mohammed
    Zhang, Jing-Yuan
    Zhang, Kun-Peng
    Pang, Qi
    NEUROLOGICAL RESEARCH, 2014, 36 (05) : 461 - 467
  • [30] Neuroform stent-assisted coiling of intracranial aneurysms: a 5 year single-center experience and follow-up
    Liang, Guobiao
    Gao, Xu
    Li, Zhiqing
    Wei, Xuezhong
    Xue, Hongli
    NEUROLOGICAL RESEARCH, 2010, 32 (07) : 721 - 727