Y-stent assisted coiling of bifurcation aneurysms with Enterprise stent: long-term follow-up
被引:48
|作者:
Limbucci, Nicola
[1
]
Renieri, Leonardo
[1
]
Nappini, Sergio
[1
]
Consoli, Arturo
[1
]
Rosi, Andrea
[1
]
Mangiafico, Salvatore
[1
]
机构:
[1] Careggi Univ Hosp, Intervent Neuroradiol Unit, Florence, Italy
关键词:
BASILAR TIP ANEURYSMS;
SINGLE-CENTER EXPERIENCE;
ENDOVASCULAR TREATMENT;
INTRACRANIAL ANEURYSMS;
CEREBRAL ANEURYSMS;
EMBOLIZATION;
CONFIGURATION;
PLACEMENT;
DEVICE;
ARTERY;
D O I:
10.1136/neurintsurg-2014-011483
中图分类号:
R445 [影像诊断学];
学科分类号:
100207 ;
摘要:
Background Y-stent assisted coiling has been proposed for the treatment of wide-neck bifurcation aneurysms, but there are many technical variations. We report our single-center experience of Y-stent assisted coiling of bifurcation aneurysms with the closed cell Enterprise stent in order to evaluate the safety and long-term results of this technique. The literature on Y-stenting and its hemodynamic effects are reviewed. Methods Fifty-two consecutive patients with wide-neck bifurcation aneurysms underwent Y-stent assisted coiling with two Enterprise stents. The procedure was completed in 48 cases (92.3%) and technical failure occurred in 4 cases (7.3%). Cases performed with other stents were excluded. All procedures were performed under double antiplatelet therapy. Periodic clinical and neuroradiological follow-up was performed. Results Mean neuroradiological follow-up time was 26 months. Complete immediate occlusion was obtained in 87.5% of patients. Two remnants had regrown at follow-up and were recoiled, achieving complete occlusion. The late neuroradiological occlusion rate was: complete occlusion 93.6%, neck remnant 4.3%, sac remnant 2.1%. No in-stent stenosis was detected at follow-up. Among the 48 procedures, two complications occurred (4.2%). Mortality was 2.1%. No delayed ischemic stroke occurred. Conclusions Y-stent assisted coiling has a high immediate occlusion rate and very good long-term stability. The procedure is relatively safe, although the complication and mortality rates are not negligible. Two Enterprise stents can be safely used for Y-stenting and, indeed, offer the advantage of easier catheterization, delivery and deployment into distal and tortuous vessels than open cell stents.
引用
收藏
页码:158 / 162
页数:5