Fracture resistance of single-tooth implant-supported zirconia-based indirect composite-layered molar restorations

被引:25
作者
Taguchi, Kohei [1 ]
Komine, Futoshi [2 ]
Fushiki, Ryosuke [2 ]
Blatz, Markus B. [3 ]
Kamio, Shingo [1 ]
Matsumura, Hideo [2 ]
机构
[1] Nihon Univ Grad Sch Dent, Tokyo, Japan
[2] Nihon Univ Sch Dent, Dept Fixed Prosthodont, Tokyo 1018310, Japan
[3] Univ Penn Sch Dent Med, Dept Prevent & Restorat Sci, Philadelphia, PA USA
关键词
dental implant; fracture resistance; implant framework; indirect composite material; zirconia ceramics; PROSPECTIVE CLINICAL-TRIAL; FIXED PARTIAL DENTURES; FREE POLYMER CROWNS; VENEERING MATERIAL; FIBER REINFORCEMENT; COMPLICATION RATES; CERAMIC CROWNS; BITE FORCE; IN-VITRO; STRENGTH;
D O I
10.1111/clr.12199
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study evaluated the fracture resistance of single-tooth implant-supported zirconia-based indirect composite-layered molar restorations. Material and methods: Forty-four titanium abutments (GingiHue Post) were placed on dental implants (Osseotite Implant). Standardized single-tooth cement-retained implant-supported mandibular molar restorations were fabricated for each of four test groups (n = 11) as follows: porcelain-fused-to-metal crowns (PFM), zirconia-based all-ceramic crowns (ZAC), zirconia-based indirect composite-layered crowns primed with Estenia Opaque Primer for zirconia frameworks (ZIC-E), and zirconia-based indirect composite-layered crowns (ZIC). The crowns were luted with a glass-ionomer cement (Ketac Cem Easymix). F'racture resistance (N) was determined by force application of a perpendicular load to the crowns with a universal testing machine. One-way analysis of variance (ANOVA) and the Tukey's HSD test were used to assess differences in fracture resistance values (alpha = 0.05). Results: Mean fracture resistances (SD) were 3.09 (0.22) kN, 3.11 (0.34) kN, 2.84 (0.21) kN, and 2.50 (0.36) kN for the PFM, ZAC, ZIC-E, and ZIC groups, respectively. Fracture resistance in the ZIC specimens was significantly lower (P < 0.044) than that in the other groups, which did not significantly differ. Conclusions: The fracture resistance of single-tooth implant-supported zirconia-based indirect composite-layered molar crowns primed with Estenia Opaque Primer for zirconia frameworks (ZIC-E) is comparable to that of porcelain-fused-to-metal (PFM) and zirconia-based all-ceramic (ZAC) restorations. Application of Estenia Opaque Primer to zirconia ceramic framework provides superior fracture resistance in implant-supported zirconia-based indirect composite-layered molar crowns.
引用
收藏
页码:983 / 991
页数:9
相关论文
共 48 条
  • [1] Ababneh KT, 2011, ORAL HLTH PREV DENT, V9, P395
  • [2] Agustín-Panadero R, 2012, INT J PROSTHODONT, V25, P294
  • [3] Andersson M, 1998, QUINTESSENCE INT, V29, P285
  • [4] Bates J F, 1976, J Oral Rehabil, V3, P57, DOI 10.1111/j.1365-2842.1976.tb00929.x
  • [5] Behr M, 2003, INT J PROSTHODONT, V16, P239
  • [6] Beuer F, 2010, QUINTESSENCE INT, V41, P631
  • [7] High-strength CAD/CAM-fabricated veneering material sintered to zirconia copings - A new fabrication mode for all-ceramic restorations
    Beuer, Florian
    Schweiger, Josef
    Eichberger, Marlis
    Kappert, Heinrich F.
    Gernet, Wolfgang
    Edelhoff, Daniel
    [J]. DENTAL MATERIALS, 2009, 25 (01) : 121 - 128
  • [8] Thin-wall ceramic CAD/CAM crown copings: strength and fracture pattern
    Bindl, A.
    Luthy, H.
    Mormann, W. H.
    [J]. JOURNAL OF ORAL REHABILITATION, 2006, 33 (07) : 520 - 528
  • [9] Bohlsen F, 2003, QUINTESSENCE INT, V34, P493
  • [10] Biological and technical complications and failures with fixed partial dentures (FPD) on implants and teeth after four to five years of function
    Brägger, U
    Aeschlimann, S
    Bürgin, W
    Hämmerle, CHF
    Lang, NP
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2001, 12 (01) : 26 - 34