Intraocular Pressure Measurements After Descemet Membrane Endothelial Keratoplasty

被引:15
作者
Maier, Anna-Karina [1 ]
Gundlach, Enken [1 ]
Pahlitzsch, Milena [1 ]
Gonnermann, Johannes [1 ]
Corkhill, Caitlin [1 ]
Bertelmann, Eckart [1 ]
Joussen, Antonia M. [1 ]
Klamann, Matthias K. J. [1 ]
Torun, Necip [1 ]
机构
[1] Charite Univ Med Berlin, Dept Ophthalmol, Berlin, Germany
关键词
DMEK; intraocular pressure; central corneal thickness; Goldmann applanation tonometry; dynamic contour tonometry; DYNAMIC CONTOUR TONOMETRY; GOLDMANN APPLANATION TONOMETRY; CENTRAL CORNEAL THICKNESS; OCULAR PULSE AMPLITUDE; PRO REBOUND TONOMETER; NONCONTACT TONOMETER; GRAFT-SURVIVAL; RISK-FACTORS; GLAUCOMA; ICARE;
D O I
10.1097/IJG.0000000000000593
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:Intraocular pressure (IOP) elevation occurs regularly after Descemet membrane endothelial keratoplasty (DMEK). This study evaluated the effect of central corneal thickness (CCT) on the IOP after DMEK.Patients and Methods:This prospective study recorded the IOP of 46 eyes from 46 patients preoperatively, and then 1 and 3 months after DMEK. IOP measurement was performed by noncontact pneumatic tonometry (NCT), iCare, Goldmann applanation tonometry (GAT), and dynamic contour tonometry (DCT). CCT was analyzed by anterior-segment optical coherence tomography.Results:Mean IOPs as measured by NCT, iCare, GAT, and DCT, respectively, were 14.3, 11.6, 12.7, and 16.0 mm Hg preoperatively; 13.1, 12.6, 12.7, and 16.0 mm Hg after 1 month; and 14.7, 14.5, 12.9, and 17.7 mm Hg after 3 months. There was a correlation of IOP measurements between GAT and NCT (P=0.119), GAT and iCare (P=0.892), and iCare and NCT (P=0.081) after 1 month and between iCare and NCT (P=0.702) after 3 months. Although GAT recorded approximately stable IOP values, NCT, iCare, and DCT tended to measure a higher IOP postoperatively than preoperatively. Preoperatively, correlations between IOP and CCT were not statistically significant for any measurement technique. After 3 months, the IOP measured by NCT and iCare correlated significantly with CCT (P=0.003, 0.041).Conclusions:Correlation between the different measurement techniques was poor and showed a broad distribution of limits of agreement. Therefore, a change between the 4 techniques during follow-up is not recommended. Nevertheless, all techniques detected the IOP elevation during follow-up, requiring therapy.
引用
收藏
页码:258 / 265
页数:8
相关论文
共 56 条
[1]   Risk of Corneal Transplant Rejection Significantly Reduced with Descemet's Membrane Endothelial Keratoplasty [J].
Anshu, Arundhati ;
Price, Marianne O. ;
Price, Francis W., Jr. .
OPHTHALMOLOGY, 2012, 119 (03) :536-540
[2]   Risk factors for endothelial cell loss post-keratoplasty [J].
Bertelmann, Eckart ;
Pleyer, Uwe ;
Rieck, Peter .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2006, 84 (06) :766-770
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Comparison of Dynamic Contour Tonometry with Goldmann Applanation Tonometry following Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK) [J].
Bochmann, F. ;
Kaufmann, C. ;
Becht, C. ;
Bachmann, L. M. ;
Thiel, M. A. .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2009, 226 (04) :241-244
[5]   Dynamic contour tonometry in comparison to intracameral IOP measurements [J].
Boehm, Andreas G. ;
Weber, Anja ;
Pillunat, Lutz E. ;
Koch, Rainer ;
Spoerl, Eberhard .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (06) :2472-2477
[6]  
Burvenich H, 2005, Bull Soc Belge Ophtalmol, P63
[7]   Comparison of dynamic contour tonometry and Goldmann applanation tonometry in deep lamellar and penetrating keratoplasties [J].
Ceruti, Piero ;
Morbio, Roberta ;
Marraffa, Michele ;
Marchini, Giorgio .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 145 (02) :215-221
[8]   Corneal Thickness and Intraocular Pressure in Edematous Corneas Before and After Descemet Stripping With Automated Endothelial Keratoplasty [J].
Chang, Diane T. W. ;
Pantcheva, Mina B. ;
Noecker, Robert J. .
CORNEA, 2010, 29 (10) :1125-1130
[9]   Intraocular pressure and corneal biomechanics in Fuchs' endothelial dystrophy and after posterior lamellar keratoplasty [J].
Clemmensen, Kare ;
Hjortdal, Jesper .
ACTA OPHTHALMOLOGICA, 2014, 92 (04) :350-354
[10]   Systematic Review of the Agreement of Tonometers with Goldmann Applanation Tonometry [J].
Cook, Jonathan Alistair ;
Botello, Adriana Paola ;
Elders, Andrew ;
Ali, Alia Fathi ;
Azuara-Blanco, Augusto ;
McCormack, Kirsty ;
Burr, Jennifer Margaret .
OPHTHALMOLOGY, 2012, 119 (08) :1552-1557