Intra-Abdominal Pressure Measurements in Term Pregnancy and Postpartum: An Observational Study

被引:32
作者
Staelens, Anneleen S. E. [1 ,2 ]
Van Cauwelaert, Stefan [1 ]
Tomsin, Kathleen [1 ,2 ]
Mesens, Tinne [2 ]
Malbrain, Manu L. N. [3 ]
Gyselaers, Wilfried [1 ,2 ]
机构
[1] Hasselt Univ, Dept Med & Life Sci, Hasselt, Belgium
[2] Ziekenhuis Oost Limburg, Dept Obstet & Gynaecol, Genk, Belgium
[3] ZNA Stuivenberg, Ziekenhuis Netwerk Antwerpen, Dept Intens Care, Antwerp, Belgium
关键词
ABDOMINAL COMPARTMENT SYNDROME; INTERNATIONAL-CONFERENCE; BLADDER PRESSURE; VENOUS DISEASE; HYPERTENSION; EXPERTS; WOMEN;
D O I
10.1371/journal.pone.0104782
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective: To determine intra-abdominal pressure (IAP) and to evaluate the reproducibility of IAP-measurements using the Foley Manometer Low Volume (FMLV) in term uncomplicated pregnancies before and after caesarean section (CS), relative to two different reference points and to non-pregnant values. Design: Observational cohort study. Setting: Secondary level referral center for feto-maternal medicine. Population: Term uncomplicated pregnant women as the case-group and non-pregnant patients undergoing a laparoscopic assisted vaginal hysterectomy (LAVH) as control group. Methods: IAP was measured in 23 term pregnant patients, before and after CS and in 27 women immediately after and 1 day after LAVH. The midaxillary line was used as zero-reference (IAP(MAL)) in all patients and in 13 CS and 13 LAVH patients, the symphysis pubis (IAP(SP)) was evaluated as additional zero-reference. Intraobserver correlation (ICC) was calculated for each zero-reference. Paired student's t-tests were performed to compare IAP values and Pearson's correlation was used to assess correlations between IAP and gestational variables. Main outcome measures: ICC before and after surgery, IAP before and after CS, IAP after CS and LAVH. Results: The ICC for IAP(MAL) before CS was lower than after (0.71 versus 0.87). Both mean IAP(MAL) and IAP(SP) were significantly higher before CS than after: 14.0 +/- 2.6 mmHg versus 9.8 +/- 3.0 mmHg (p<0.0001) and 8.2 +/- 2.5 mmHg versus 3.5 +/- 1.9 mmHg (p = 0.010), respectively. After CS, IAP was not different from values measured in the LAVH-group. Conclusion: IAP-measurements using FMLV is reproducible in pregnant women. Before CS, IAP is increased in the range of intra-abdominal hypertension for non-pregnant individuals. IAP significantly decreases to normal values after delivery.
引用
收藏
页数:8
相关论文
共 33 条
[1]   Normative postpartum intraabdominal pressure: potential implications in the diagnosis of abdominal compartment syndrome [J].
Abdel-Razeq, Sonya S. ;
Campbell, Katherine ;
Funai, Edmund F. ;
Kaplan, Lewis J. ;
Bahtiyar, Mert Ozan .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2010, 203 (02) :149.e1-149.e4
[2]  
Al-Khan A, 2011, J REPROD MED, V56, P53
[3]   Chronically increased intra-abdominal pressure produces systemic hypertension in dogs [J].
Bloomfield, GL ;
Sugerman, HJ ;
Blocher, CR ;
Gehr, TWB ;
Sica, DA .
INTERNATIONAL JOURNAL OF OBESITY, 2000, 24 (07) :819-824
[4]   Results from the International Conference of Experts on Intra-Abdominal Hypertension and Abdominal Compartment Syndrome.: II.: Recommendations [J].
Cheatham, Michael L. ;
Malbrain, Manu L. N. G. ;
Kirkpatrick, Andrew ;
Sugrue, Michael ;
Parr, Michael ;
De Waele, Jan ;
Balogh, Zsolt ;
Leppaeniemi, Ari ;
Olvera, Claudia ;
Ivatury, Rao ;
D'Amours, Scott ;
Wendon, Julia ;
Hillman, Ken ;
Wilmer, Alexander .
INTENSIVE CARE MEDICINE, 2007, 33 (06) :951-962
[5]  
Cheatham ML, 2011, AM SURGEON, V77, pS78
[6]   Measurement of intra-abdominal pressure in term pregnancy: a pilot study [J].
Chun, R. ;
Baghirzada, L. ;
Tiruta, C. ;
Kirkpatrick, A. W. .
INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2012, 21 (02) :135-139
[7]   Intra-abdominal pressure, intra-abdominal hypertension, and pregnancy: a review [J].
Chun, Rosaleen ;
Kirkpatrick, Andrew W. .
ANNALS OF INTENSIVE CARE, 2012, 2
[8]   A novel use of recombinant factor VIIa in HELLP syndrome associated with spontaneous hepatic rupture and abdominal compartment syndrome [J].
Dart, BW ;
Cockerham, WT ;
Torres, C ;
Kipikasa, JH ;
Maxwell, RA .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2004, 57 (01) :171-174
[9]   What is normal intra-abdominal pressure and how is it affected by positioning, body mass and positive end-expiratory pressure? [J].
De Keulenaer, B. L. ;
De Waele, J. J. ;
Powell, B. ;
Malbrain, M. L. N. G. .
INTENSIVE CARE MEDICINE, 2009, 35 (06) :969-976
[10]   Intra- and interobserver variability during in vitro validation of two novel methods for intra-abdominal pressure monitoring [J].
De Potter, TJR ;
Dits, H ;
Malbrain, MLNG .
INTENSIVE CARE MEDICINE, 2005, 31 (05) :747-751