A device for the direct coupling of high-resolution separation techniques with PIXE

被引:1
作者
Vogt, J [1 ]
Butz, T [1 ]
Vogt, C [1 ]
Wittrisch, H [1 ]
Werner, G [1 ]
机构
[1] UNIV LEIPZIG,FAK CHEM & MINERAL,D-04103 LEIPZIG,GERMANY
关键词
D O I
10.1016/0168-583X(95)00920-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The behaviour of elements (especially metals such as Mn, Fe, Cu, Zn, Pb, etc.) in organisms and ecosystems can be studied in detail only if their bonding forms can be determined (speciation). Therefore, the combination of high-resolution separation techniques (e.g., capillary zone electrophoresis (CZE)) with PIXE should provide a powerful tool for the speciation analysis of metal-containing species. A device for this coupling is described. Its main constituent is a capillary with an ''ion window'' combined with a high-efficiency LEGe detector. With the presented experimental setup, detection limits down to 1x10(-5) M can be achieved.
引用
收藏
页码:266 / 269
页数:4
相关论文
共 9 条
  • [1] STUDY OF ISOTACHOPHORETIC SEPARATION BEHAVIOR OF METAL-CATIONS BY MEANS OF PARTICLE-INDUCED X-RAY-EMISSION .4. SEPARATION OF METAL-IONS IN A NONRADIOACTIVE MODEL SOLUTION OF A HIGH-LEVEL LIQUID WASTE
    HIROKAWA, T
    UEDA, M
    IJYUIN, A
    YOSHIDA, S
    NISHIYAMA, F
    KISO, Y
    [J]. JOURNAL OF CHROMATOGRAPHY, 1993, 633 (1-2): : 261 - 272
  • [2] STUDY OF ISOTACHOPHORETIC SEPARATION BEHAVIOR OF METAL-CATIONS BY MEANS OF PARTICLE-INDUCED X-RAY-EMISSION .5. FRACTIONATION OF PLATINUM-GROUP ELEMENTS FROM A MODEL SOLUTION OF NUCLEAR-FUEL WASTE BY MEANS OF CONTINUOUS FREE-FLOW ISOTACHOPHORESIS
    HIROKAWA, T
    OHTA, T
    TANAKA, I
    NAKAMURA, K
    XIA, W
    NISHIYAMA, F
    KISO, Y
    [J]. JOURNAL OF CHROMATOGRAPHY, 1993, 638 (02): : 215 - 223
  • [3] STUDY OF ISOTACHOPHORETIC SEPARATION BEHAVIOR OF METAL-CATIONS BY MEANS OF PARTICLE-INDUCED X-RAY-EMISSION .1. SEPARATION OF 20 METAL-CATIONS USING AN ACETIC-ACID BUFFER SYSTEM AND ALPHA-HYDROXYISOBUTYRIC ACID COMPLEX-FORMING SYSTEM
    HIROKAWA, T
    HU, JY
    EGUCHI, S
    NISHIYAMA, F
    KISO, Y
    [J]. JOURNAL OF CHROMATOGRAPHY, 1991, 538 (02): : 413 - 423
  • [4] PREPARATIVE ISOTACHOPHORETIC ANALYZER EQUIPPED WITH A DROPWISE FRACTIONATING DEVICE
    HIROKAWA, T
    HU, JY
    UMEDA, K
    KIMURA, G
    IKEDA, H
    NISHIYAMA, F
    KISO, Y
    [J]. JOURNAL OF CHROMATOGRAPHY, 1990, 513 : 297 - 310
  • [5] HIROKAWA T, 1987, REP RES CENT ION BEA, V513, P103
  • [6] ELEMENTAL ANALYSIS OF LIQUIDS BY EXTERNAL BEAM PIXE DOWN TO PPB LEVEL
    KHAN, AH
    KHALIQUZZAMAN, M
    HUSAIN, M
    ABDULLAH, M
    KATSANOS, AA
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1979, 165 (02): : 253 - 259
  • [7] Kuhn R., 1993, capillary electrophoresis: principles and practice, DOI DOI 10.1007/978-3-642-78058-5
  • [8] SIMULTANEOUS PIXE AND PIGE ANALYSIS OF METALLOPROTEINS SEPARATED BY CELLULOSE-ACETATE ELECTROPHORESIS
    SZOKEFALVINAGY, Z
    DEMETER, I
    HOLLOSNAGY, K
    RAISANEN, J
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1993, 75 (1-4) : 165 - 168
  • [9] On-line coupling of PIXE with capillary zone electrophoresis (CZE)
    Vogt, J
    Vogt, C