Analysis of results related to good and bad outcomes of Intacs implantation for keratoconus correction

被引:108
作者
Alió, JL
Shabayek, MH
Belda, JI
Correas, P
Feijoo, ED
机构
[1] Miguel Hernandez Univ, Sch Med, Inst Oftalmol Alicante, Vissum Dept Cornea & Refract Surg, Alicante 03016, Spain
[2] Miguel Hernandez Univ, Sch Med, Div Ophthalmol, Alicante 03016, Spain
[3] Res Inst Ophthalmol, Giza, Egypt
[4] Inst Galego Oftalmol, Santiago De Compostela, Spain
关键词
D O I
10.1016/j.jcrs.2006.02.012
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate factors influencing good and poor outcomes after intracorneal ring segment implantation to correct keratoconus. SETTING: Instituto Oftalmologico de Alicante (Vissum Corporation), University of Miguel Hernandez, Alicante, Spain. METHODS: A retrospective comparative study of the visual outcome, 25 eyes of 21 patients were implanted after intracorneal ring segments (Intacs, Addition Technology) as a method to correct keratoconus. Outcomes were evaluated 6 months after implantation based on the visual results. Group A comprised 20 eyes that gained 3 lines or more of best spectacle-corrected visual acuity (BSCVA) to correct keratoconus, and Group B comprised 5 eyes that lost 1 line of BSCVA. RESULTS: In Group A, the preoperative mean BSCVA was 0.43 (20/50) and the postoperative mean BSCVA, 0.82 (20/20) (P <=.0001). In Group B, the preoperative mean BSCVA was 0.36 (20/63) and the postoperative mean BSCVA, 0.24 (20/80) (P <=.02). The preoperative mean sphere power was 3.90 diopters (D) greater in Group B than in Group A (P <=.007); the mean spherical equivalent was 4.36 D greater (P <=.007), and the mean K-reading was 6.91 D greater (P <=.001). The postoperative reduction in spherical dioptric power was 2.11 D (P <=.027) and the mean spherical equivalent, 2.81 D (P <=.003), significant only in Group A. The reduction in mean central K-readings was 4.30 D (P <=.0001) in Group A and 6.19 D (P <=.014) in Group B. The correlation of the preoperative mean K value to the postoperative BSCVA was significant at the .01 level by the Pearson test (-0.67). In Group A, all eyes (100%) had a mean K-reading <= 53 D. In Group B, 4 eyes (80%) had a mean K-reading >= 55 D. CONCLUSION: Intacs provided better results in visual acuity and corneal topography quality and significantly reduced the spherical equivalent in eyes with keratoconus with relatively low mean K values (<= 53 D) and a relatively low spherical equivalent. In advanced keratoconus (mean K-reading >= 55 D), poor results can be anticipated.
引用
收藏
页码:756 / 761
页数:6
相关论文
共 15 条
[1]  
Alió JL, 2006, J REFRACT SURG, V22, P307
[2]   One or 2 Intacs segments for the correction of keratoconus [J].
Alió, JL ;
Artola, A ;
Hassanein, A ;
Haroun, H ;
Galal, A .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (05) :943-953
[3]   Changes in keratoconic corneas after intracorneal ring segment explantation and reimplantation [J].
Alió, JL ;
Artola, A ;
Ruiz-Moreno, JM ;
Hassanein, A ;
Galal, A ;
Awadalla, MA .
OPHTHALMOLOGY, 2004, 111 (04) :747-751
[4]  
Buratto L, 1998, J REFRACT SURG, V14, P517
[5]  
Burris T E, 1991, Refract Corneal Surg, V7, P46
[6]   Correcting keratoconus with intracorneal rings [J].
Colin, J ;
Cochener, B ;
Savary, G ;
Malet, F .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (08) :1117-1122
[7]   PRK in patients with a keratoconic topography picture. The concept of a physiological 'displaced apex syndrome' [J].
Doyle, SJ ;
Hynes, E ;
Naroo, S ;
Shah, S .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1996, 80 (01) :25-28
[8]   KERATOCONUS AND RELATED NONINFLAMMATORY CORNEAL THINNING DISORDERS [J].
KRACHMER, JH ;
FEDER, RS ;
BELIN, MW .
SURVEY OF OPHTHALMOLOGY, 1984, 28 (04) :293-322
[9]   Three year results of photoastigmatic refractive keratectomy for mild and atypical keratoconus [J].
Kremer, I ;
Shochot, Y ;
Kaplan, A ;
Blumenthal, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (12) :1581-1588
[10]  
LOVISOLO CF, 2002, INTRASTROMAL CORNEAL, P95