Comparison of T1-weighted 2D TSE, 3D SPGR, and two-point 3D Dixon MRI for automated segmentation of visceral adipose tissue at 3 Tesla

被引:17
作者
Fallah, Faezeh [1 ,2 ]
Machann, Juergen [2 ,3 ,4 ]
Martirosian, Petros [2 ]
Bamberg, Fabian [5 ]
Schick, Fritz [2 ]
Yang, Bin [1 ]
机构
[1] Univ Stuttgart, Inst Signal Proc & Syst Theory, Pfaffenwaldring 47, D-70569 Stuttgart, Germany
[2] Univ Clin Tubingen, Sect Expt Radiol, Dept Diagnost & Intervent Radiol, Tubingen, Germany
[3] Univ Tubingen, Inst Diabet Res & Metab Dis IDM, Helmholtz Ctr Munich, Tubingen, Germany
[4] German Ctr Diabet Res DZD, Tubingen, Germany
[5] Univ Clin Tubingen, Dept Diagnost & Intervent Radiol, Tubingen, Germany
关键词
Visceral adipose tissue; Automatic volumetry; Two-point Dixon imaging; T1-weighted imaging; 3; Tesla; FAT; QUANTIFICATION; WATER; CLASSIFICATION; ACCUMULATION; TOPOGRAPHY; SEPARATION; IDEAL; DEEP;
D O I
10.1007/s10334-016-0588-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate and compare conventional T1-weighted 2D turbo spin echo (TSE), T1-weighted 3D volumetric interpolated breath-hold examination (VIBE), and two-point 3D Dixon-VIBE sequences for automatic segmentation of visceral adipose tissue (VAT) volume at 3 Tesla by measuring and compensating for errors arising from intensity nonuniformity (INU) and partial volume effects (PVE). The body trunks of 28 volunteers with body mass index values ranging from 18 to 41.2 kg/m(2) (30.02 +/- 6.63 kg/m(2)) were scanned at 3 Tesla using three imaging techniques. Automatic methods were applied to reduce INU and PVE and to segment VAT. The automatically segmented VAT volumes obtained from all acquisitions were then statistically and objectively evaluated against the manually segmented (reference) VAT volumes. Comparing the reference volumes with the VAT volumes automatically segmented over the uncorrected images showed that INU led to an average relative volume difference of -59.22 +/- 11.59, 2.21 +/- 47.04, and -43.05 +/- 5.01 % for the TSE, VIBE, and Dixon images, respectively, while PVE led to average differences of -34.85 +/- 19.85, -15.13 +/- 11.04, and -33.79 +/- 20.38 %. After signal correction, differences of -2.72 +/- 6.60, 34.02 +/- 36.99, and -2.23 +/- 7.58 % were obtained between the reference and the automatically segmented volumes. A paired-sample two-tailed t test revealed no significant difference between the reference and automatically segmented VAT volumes of the corrected TSE (p = 0.614) and Dixon (p = 0.969) images, but showed a significant VAT overestimation using the corrected VIBE images. Under similar imaging conditions and spatial resolution, automatically segmented VAT volumes obtained from the corrected TSE and Dixon images agreed with each other and with the reference volumes. These results demonstrate the efficacy of the signal correction methods and the similar accuracy of TSE and Dixon imaging for automatic volumetry of VAT at 3 Tesla.
引用
收藏
页码:139 / 151
页数:13
相关论文
共 52 条
[21]   KORA -: A research platform for population based health research [J].
Holle, R ;
Happich, M ;
Löwel, H ;
Wichmann, HE .
GESUNDHEITSWESEN, 2005, 67 :S19-S25
[22]   Automatic intra-subject registration-based segmentation of abdominal fat from water-fat MRI [J].
Joshi, Anand A. ;
Hu, Houchun H. ;
Leahy, Richard M. ;
Goran, Michael I. ;
Nayak, Krishna S. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (02) :423-430
[23]   SNAKES - ACTIVE CONTOUR MODELS [J].
KASS, M ;
WITKIN, A ;
TERZOPOULOS, D .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 1987, 1 (04) :321-331
[24]   Impact of incorrect tissue classification in Dixon-based MR-AC: fat-water tissue inversion [J].
Ladefoged C.N. ;
Hansen A.E. ;
Keller S.H. ;
Holm S. ;
Law I. ;
Beyer T. ;
Højgaard L. ;
Kjær A. ;
Andersen F.L. .
EJNMMI Physics, 1 (1) :1-9
[25]   Partial-volume Bayesian classification of material mixtures in MR volume data using voxel histograms [J].
Laidlaw, DH ;
Fleischer, KW ;
Barr, AH .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (01) :74-86
[26]  
Leinhard OD, 2008, 19 IEEE INT C PATT R
[27]  
Lu W, 2010, 7 IEEE INT S BIOM IM
[28]   Dixon techniques for water and fat imaging [J].
Ma, Jingfei .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (03) :543-558
[29]   Age and gender related effects on adipose tissue compartments of subjects with increased risk for type 2 diabetes: a whole body MRI/MRS study [J].
Machann, J ;
Thamer, C ;
Schnoedt, B ;
Stefan, N ;
Stumvoll, M ;
Haring, HU ;
Claussen, CD ;
Fritsche, A ;
Schick, F .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2005, 18 (03) :128-137
[30]   Standardized assessment of whole body adipose tissue topography by MRI [J].
Machann, J ;
Thamer, C ;
Schnoedt, B ;
Haap, M ;
Haring, HU ;
Claussen, CD ;
Stumvoll, M ;
Fritsche, A ;
Schick, F .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (04) :455-462