Endovascular Treatment of Ruptured Wide-Necked Anterior Communicating Artery Aneurysms Using a Low-Profile Visualized Intraluminal Support (LVIS) Device

被引:3
|
作者
Xue, Gaici [1 ]
Liu, Peng [2 ]
Xu, Fengfeng [3 ]
Fang, Yibin [2 ]
Li, Qiang [2 ]
Hong, Bo [2 ]
Xu, Yi [2 ]
Liu, Jianmin [2 ]
Huang, Qinghai [2 ]
机构
[1] Gen Hosp Southern Theatre Command Peoples Liberat, Dept Neurosurg, Guangzhou, Peoples R China
[2] Navy Med Univ, Changhai Hosp, Dept Neurosurg, Shanghai, Peoples R China
[3] Navy Med Univ, Naval Med Ctr Peoples Liberat Army China, Dept Neurosurg, Shanghai, Peoples R China
来源
FRONTIERS IN NEUROLOGY | 2021年 / 11卷
基金
中国国家自然科学基金;
关键词
intracranial aneurysm; ruptured; anterior communicating artery; LVIS stents; safety; wide-necked aneurysms; INTRACRANIAL ANEURYSMS; COIL EMBOLIZATION; CONSECUTIVE SERIES; LOCATION; SIZE;
D O I
10.3389/fneur.2020.611875
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To evaluate the safety and efficacy of low-profile visualized intraluminal support (LVIS) stent-assisted coiling for the treatment of ruptured wide-necked anterior communicating artery (ACoA) aneurysms. Methods: The clinical and angiographic data of 31 acutely ruptured wide-necked ACoA aneurysms treated with LVIS stent-assisted coiling between January 2014 and December 2018 were retrospectively reviewed. Results: All stents were successfully deployed. The immediate angiographic results were modified Raymond-Roy class I in 27 cases, modified Raymond-Roy class II in 2 cases, and modified Raymond-Roy class IIIa in 2 cases. Intraoperative thrombosis and postoperative aneurysmal rebleeding occurred in one case each. Two patients (6.5%) who were admitted due to poor clinical grade conditions died during hospital admission as a result of initial bleeding. Angiographic follow-up (mean: 12.9 months) was performed for 26 patients, the results of which demonstrated that 25 aneurysms were completely occluded and one was class II. The last clinical follow-up (mean: 25.3 months) outcomes demonstrated that 27 patients had favorable clinical outcomes and two had poor clinical outcomes. Conclusion: LVIS stent-assisted coiling for ruptured wide-necked ACoA aneurysms was safe and effective, with a relatively low rate of perioperative complications and a high rate of complete occlusion at follow-up.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Y-configuration stenting for coiling of wide-neck bifurcation aneurysms using Low-profile Visualized Intraluminal Support Junior
    Park, Keun Young
    Kim, Byung Moon
    Kim, Dong Joon
    Chung, Joonho
    Lee, Jae Whan
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2019, 11 (04) : 400 - 404
  • [32] Small ruptured and unruptured complex cerebral aneurysms: Single center experience of low-profile visualized intraluminal support stent
    Lv, Xianli
    Jiang, Chuhan
    Liang, Shikai
    JOURNAL OF NEURORESTORATOLOGY, 2019, 7 (04): : 235 - 241
  • [33] Cerebral aneurysms treated with low-profile visualized intraluminal support device (LVIS Jr) Y-stent constructs: Technical experience with a single microcatheter technique
    Son, Colin
    Page, Paul
    Niemann, David
    INTERVENTIONAL NEURORADIOLOGY, 2020, 26 (02) : 156 - 163
  • [34] Treatment of complex ruptured anterior communicating arterial aneurysms by endovascular coil embolisation of the anterior communicating artery
    Fang, Chun
    Li, Ming-Hua
    Zhu, Yue-Qi
    Tan, Hua-Qiao
    Zhang, Pei-Lei
    Wang, Jue
    BRITISH JOURNAL OF NEUROSURGERY, 2011, 25 (05) : 591 - 595
  • [35] Endovascular Treatment of Wide-Necked Visceral Artery Aneurysms Using the Neurovascular Comaneci Neck-Bridging Device: A Technical Report
    Maingard, Julian
    Kok, Hong Kuan
    Phelan, Emma
    Logan, Caitriona
    Ranatunga, Dinesh
    Brooks, Duncan Mark
    Chandra, Ronil V.
    Lee, Michael J.
    Asadi, Hamed
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2017, 40 (11) : 1784 - 1791
  • [36] Low-profile visualized intraluminal support Blue stenting within a Neuroform Atlas stent for a large wide-necked aneurysm: A case report and a bench-top experiment
    Hayashi, Tomoko
    Ikeda, Hiroyuki
    Ishibashi, Ryota
    Fujiwara, Toshio
    Kaneko, Ryosuke
    Uezato, Minami
    Kinosada, Masanori
    Kurosaki, Yoshitaka
    Handa, Akira
    Chin, Masaki
    NEURORADIOLOGY JOURNAL, 2022, 35 (01) : 126 - 131
  • [37] The pCONus Device for Treatment of Complex Wide-Neck Anterior Communicating Artery Aneurysms
    Labeyrie, Paul Emile
    Gory, Benjamin
    Aguilar-Perez, Marta
    Pomero, Elisa
    Biondi, Alessandra
    Riva, Roberto
    Turjman, Francis
    Henkes, Hans
    WORLD NEUROSURGERY, 2017, 101 : 498 - 505
  • [38] Preliminary experience with the use of low profile visualized intraluminal support device in basilar artery for aneurysm treatment
    Wang, Chuanchuan
    Wu, Yina
    Feng, Zhengzhe
    Wang, Jing
    Li, Qiang
    Zhao, Rui
    Hong, Bo
    Xu, Yi
    Huang, Qinghai
    Fang, Yibin
    Liu, Jianmin
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2019, 11 (04) : 405 - 410
  • [39] Overlapped Stenting Combined with Coiling for Blood Blister-Like Aneurysms: Comparison of Low-Profile Visualized Intraluminal Support (LVIS) Stent and Non-LVIS Stent
    Zhu, Deyuan
    Fang, Yibin
    Yang, Pengfei
    Zhang, Ping
    Chen, Lei
    Xu, Yi
    Hong, Bo
    Huang, Qinghai
    Liu, Jian-Min
    WORLD NEUROSURGERY, 2017, 104 : 729 - 735
  • [40] Endovascular treatment of ruptured lobulated anterior communicating artery aneurysms: A retrospective study of 24 patients
    Huang, Sheng-Xuan
    Ai, Xun-Ping
    Kang, Ze-Hui
    Chen, Zhi-Yong
    Li, Ren-Man
    Wu, Zu-Chao
    Zhu, Feng
    WORLD JOURNAL OF CLINICAL CASES, 2024, 12 (15)