Integrated Sensors for Charged-Particle Imaging Using Per-Pixel Correlated Double Sampling

被引:1
|
作者
Kleinfelder, Stuart [1 ]
Ahooie, Mona [1 ]
机构
[1] Univ Calif Irvine, Irvine, CA 92697 USA
关键词
Image sensors; particle tracker; radiation detectors; smart pixels; NOISE; DETECTOR; ARRAY;
D O I
10.1109/TNS.2009.2015298
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Monolithic CMOS cameras for direct imaging in electron microscopy and other radiation imaging applications have been developed and have been used to capture images with high signal to noise and resolution. Based on CMOS Active Pixel Sensor (APS) technology, the arrays use an 8 to 20 mu m epitaxial layer that acts as a thicker sensitive region for the liberation and collection of ionization electrons resulting from impinging charged particles. This results in a 100% fill factor and a far larger signal per incident charged particle than a typical CMOS photodiode could provide. The per-pixel CDS scheme discussed in this paper has demonstrated reductions in kT/C noise by a factor of four, to 11 electrons RMS at room temperature. The CDS scheme requires only one read instead of the two reads plus pre- and post-integration subtraction required by traditional CDS, and is hence faster than alternate schemes. In addition, the test device was used in the observation of Random Telegraph Signal noise (RTS) in small-capacitance pixels under different V-gs conditions.
引用
收藏
页码:1056 / 1061
页数:6
相关论文
共 24 条
  • [21] A Shutter-less Micro-bolometer Thermal Imaging System using Multiple Digital Correlated Double Sampling for Mobile Applications
    Park, Seunghyun
    Cho, Tei
    Kim, Minsik
    Park, Hyungchul
    Lee, Kwyro
    2017 SYMPOSIUM ON VLSI CIRCUITS, 2017, : C154 - C155
  • [22] A Shutter-less Micro-bolometer Thermal Imaging System using Multiple Digital Correlated Double Sampling for Mobile Applications
    Park, Seunghyun
    Cho, Tei
    Kim, Minsik
    Park, Hyungchul
    Lee, Kwyro
    2017 SYMPOSIUM ON VLSI TECHNOLOGY, 2017, : C154 - C155
  • [23] Transient Response of a 3-TFT Hybrid Active-Passive Pixel with Correlated Double Sampling CMOS Readout Circuit for Real-Time Medical X-ray Imaging
    Safavian, N.
    Wu, D.
    Karim, K.
    Nathan, Arokia
    2008 1ST MICROSYSTEMS AND NANOELECTRONICS RESEARCH CONFERENCE, 2008, : 85 - +
  • [24] A very low power and low signal 5 bit 50 M samples/s double sampling pipelined ADC for Monolithic Active Pixel Sensors in high energy physics and biomedical imaging applications
    Dahoumane, M.
    Bouvier, J.
    Dzahini, D.
    Martel, L. Gallin
    Lagorio, E.
    Hostachy, J-Y.
    Hu, Y.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 1366 - +