Navigator-gated free-breathing 3D balanced FFE projection renal MRA:: Comparison with contrast-enhanced breath-hold 3D MRA in a swine model

被引:16
|
作者
Spuentrup, E
Buecker, A
Meyer, J
Günther, RW
Stuber, M
机构
[1] Rhein Westfal TH Aachen, Dept Diagnost Radiol, Aachen, Germany
[2] Beth Israel Deaconess Med Ctr, Dept Med, Div Cardiovasc, Boston, MA 02215 USA
[3] Harvard Univ, Sch Med, Boston, MA 02115 USA
[4] Philips Med Syst, Best, Netherlands
关键词
magnetic resonance angiography (MRA); projection MRA; navigator technology; renal angiography; motion study;
D O I
10.1002/mrm.10271
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A cardiac-triggered, free-breathing, 3D balanced FFE projection renal MR angiography (MRA) technique with a 213 pencil beam aortic labeling pulse for selective aortic spin tagging wag developed. For respiratory motion artifact suppression during free breathing, a prospective real-time navigator was implemented for renal MRA. Images obtained with the new approach were compared with standard contrast-enhanced (CE) 3D breath-hold MRA in seven swine. Signal properties and vessel visualization were analyzed. With the presented technique, high-resolution, high-contrast renal projection MRA with superior vessel length visualization (including a greater visible number of distal branches of the renal arteries) compared to standard breath-hold CE-MRA was obtained. The present results warrant clinical studies in patients with renal artery disease. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:739 / 743
页数:5
相关论文
共 50 条
  • [1] Single breath-hold extended free-breathing navigator-gated three-dimensional coronary MRA
    Huber, ME
    Oelhafen, ME
    Kozerke, S
    Weber, OM
    Boesiger, P
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (02) : 210 - 214
  • [2] Intravascular contrast enhanced free-breathing 3D coronary MRA
    Stuber, M
    Botnar, RM
    Danias, PG
    McConnell, MV
    Manning, WJ
    CIRCULATION, 1999, 100 (18) : 229 - 229
  • [3] 3D breath-hold contrast-enhanced MRA: A preliminary experience in aorta and iliac vascular disease
    Shetty, AN
    Shirkhoda, A
    Bis, KG
    Ellwood, R
    Li, DB
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1998, 22 (02) : 179 - 185
  • [4] Motion artifact reduction and vessel enhancement for free-breathing navigator-gated coronary MRA using 3D k-space reordering
    Huber, ME
    Hengesbach, D
    Botnar, RM
    Kissinger, KV
    Boesiger, P
    Manning, WJ
    Stuber, M
    MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) : 645 - 652
  • [5] Steady-state free precession MRA of the renal arteries: Breath-hold and navigator-gated techniques vs. CE-MRA
    Maki, Jeffrey H.
    Wilson, Gregory J.
    Eubank, William B.
    Glickerman, David J.
    Pipavath, Sudhakar
    Hoogeveen, Romhild M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (04) : 966 - 973
  • [6] Contrast-enhanced 3D MRA using SENSE
    Weiger, M
    Pruessmann, KP
    Kassner, A
    Roditi, G
    Lawton, T
    Reid, A
    Boesiger, P
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 12 (05) : 671 - 677
  • [7] Breath-hold 3D gadolinium-enhanced subtraction MRA in the detection of transplant renal artery stenosis
    Luk, SH
    Chan, JHM
    Kwan, TH
    Tsui, WC
    Cheung, YK
    Yuen, MK
    CLINICAL RADIOLOGY, 1999, 54 (10) : 651 - 654
  • [8] Dynamic contrast-enhanced 3D breath hold MRA using a multiple variable orientation slab aquisition
    Shetty, AN
    Bis, KG
    MAGNETIC RESONANCE IMAGING, 1999, 17 (06) : 837 - 841
  • [9] Evaluation of large intracranial aneurysms with cine MRA and 3D contrast-enhanced MRA
    Zhu Wenzhen
    Feng Dingyi
    Qi Jianpin
    Xia Liming
    Wang Chengyuan
    Current Medical Science, 2004, 24 (1) : 95 - 98
  • [10] Evaluation of Large Intracranial Aneurysms with Cine MRA and 3D Contrast-Enhanced MRA
    朱文珍
    冯定义
    漆剑频
    夏黎明
    王承缘
    华中科技大学学报(医学英德文版), 2004, (01) : 95 - 98