Detection of formaldehyde using off-axis integrated cavity output spectroscopy with an interband cascade laser

被引:48
作者
Miller, J. H.
Bakhirkin, Y. A.
Ajtai, T.
Tittel, F. K.
Hill, C. J.
Yang, R. Q.
机构
[1] Rice Univ, Dept Elect & Comp Engn, Houston, TX 77005 USA
[2] George Washington Univ, Dept Chem, Washington, DC 20052 USA
[3] CALTECH, Jet Prop Lab, Pasadena, CA 91109 USA
来源
APPLIED PHYSICS B-LASERS AND OPTICS | 2006年 / 85卷 / 2-3期
关键词
D O I
10.1007/s00340-006-2310-2
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A continuous-wave, mid-infrared, distributed feedback, interband cascade laser was used to detect and quantify formaldehyde (H2CO) using off-axis, integrated cavity output spectroscopy in gas mixtures containing approximate to 1-25 parts in 10(6) by volume (ppmV) of H2CO. Analysis of the spectral measurements indicates that a H2CO concentration of 150 parts in 10(9) by volume (ppbV) would produce a spectrum with a signal to noise ratio of 3 for a data acquisition time of 3 s. This is a relevant sensitivity level for formaldehyde monitoring of indoor air, occupational settings, and on board spacecraft in long duration missions in particular as the detection sensitivity improves with the square root of the data acquisition time.
引用
收藏
页码:391 / 396
页数:6
相关论文
共 25 条
  • [1] Mid-infrared quantum cascade laser based off-axis integrated cavity output spectroscopy for biogenic nitric oxide detection
    Bakhirkin, YA
    Kosterev, AA
    Roller, C
    Curl, RF
    Tittel, FK
    [J]. APPLIED OPTICS, 2004, 43 (11) : 2257 - 2266
  • [2] Sub-ppbv nitric oxide concentration measurements using cw thermoelectrically cooled quantum cascade laser-based integrated cavity output spectroscopy
    Bakhirkin, YA
    Kosterev, AA
    Curl, RF
    Tittel, FK
    Yarekha, DA
    Hvozdara, L
    Giovannini, M
    Faist, J
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 2006, 82 (01): : 149 - 154
  • [3] CROSSGROVE RE, 2000, SPACECRAFT MAXIMUM A, V1
  • [4] Rapid formaldehyde monitoring in ambient air by means of mid-infrared cavity leak-out spectroscopy
    Dahnke, H
    Von Basum, G
    Kleinermanns, K
    Hering, P
    Mürtz, M
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 2002, 75 (2-3): : 311 - 316
  • [5] A simplified apparatus for ambient formaldehyde detection via GC-pHID
    Hopkins, JR
    Still, T
    Al-Haider, S
    Fisher, IR
    Lewis, AC
    Seakins, PW
    [J]. ATMOSPHERIC ENVIRONMENT, 2003, 37 (18) : 2557 - 2565
  • [6] Formaldehyde sensor using interband cascade laser based quartz-enhanced photoacoustic spectroscopy
    Horstjann, M
    Bakhirkin, YA
    Kosterev, AA
    Curl, RF
    Tittel, FK
    Wong, CM
    Hill, CJ
    Yang, RQ
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 2004, 79 (07): : 799 - 803
  • [7] Difference-frequency-based tunable absorption spectrometer for detection of atmospheric formaldehyde
    Lancaster, DG
    Fried, A
    Wert, B
    Henry, B
    Tittel, FK
    [J]. APPLIED OPTICS, 2000, 39 (24) : 4436 - 4443
  • [8] Measurements of hydrogen cyanide and its chemical production rate in a laminar methane/air, non-premixed flame using cw cavity ringdown spectroscopy
    Miller, JH
    Awtry, AR
    Moses, ME
    Jewell, AD
    Wilson, EL
    [J]. PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2002, 29 : 2203 - 2209
  • [9] Transportable, highly sensitive photoacoustic spectrometer based on a continuous-wave dual-cavity optical parametric oscillator
    Muller, F
    Popp, A
    Kuhnemann, F
    Schiller, S
    [J]. OPTICS EXPRESS, 2003, 11 (22): : 2820 - 2825
  • [10] cw Integrated cavity output spectroscopy
    O'Keefe, A
    Scherer, JJ
    Paul, JB
    [J]. CHEMICAL PHYSICS LETTERS, 1999, 307 (5-6) : 343 - 349