Quantitative Mapping of Specific Ventilation in the Human Lung using Proton Magnetic Resonance Imaging and Oxygen as a Contrast Agent

被引:2
|
作者
Geier, Eric T. [1 ]
Theilmann, Rebecca J. [2 ]
Darquenne, Chantal [1 ]
Prisk, G. Kim [1 ]
Sa, Rui Carlos [1 ]
机构
[1] Univ Calif San Diego, Dept Med, Pulm Imaging Lab, San Diego, CA 92103 USA
[2] Univ Calif San Diego, Dept Radiol, Pulm Imaging Lab, San Diego, CA 92103 USA
来源
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS | 2019年 / 148期
基金
美国国家航空航天局;
关键词
Medicine; Issue; 148; respiration; lung; specific ventilation; functional magnetic resonance imaging; oxygen enhanced magnetic resonance imaging; ventilation; SUPINE; PERFUSION; QUANTIFICATION; EXERCISE; PRONE; MRI; PET;
D O I
10.3791/59579
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Specific ventilation imaging (SVI) is a functional magnetic resonance imaging technique capable of quantifying specific ventilation - the ratio of the fresh gas entering a lung region divided by the region's end-expiratory volume - in the human lung, using only inhaled oxygen as a contrast agent. Regional quantification of specific ventilation has the potential to help identify areas of pathologic lung function. Oxygen in solution in tissue shortens the tissue's longitudinal relaxation time (T-1), and thus a change in tissue oxygenation can be detected as a change in T-1-weighted signal with an inversion recovery acquired image. Following an abrupt change between two concentrations of inspired oxygen, the rate at which lung tissue within a voxel equilibrates to a new steady-state reflects the rate at which resident gas is being replaced by inhaled gas. This rate is determined by specific ventilation. To elicit this sudden change in oxygenation, subjects alternately breathe 20-breath blocks of air (21% oxygen) and 100% oxygen while in the MRI scanner. A stepwise change in inspired oxygen fraction is achieved through use of a custom three-dimensional (3D)-printed flow bypass system with a manual switch during a short end-expiratory breath hold. To detect the corresponding change in T-1, a global inversion pulse followed by a single shot fast spin echo sequence was used to acquire two-dimensional T-1-weighted images in a 1.5 T MRI scanner, using an eight-element torso coil. Both single slice and multi-slice imaging are possible, with slightly different imaging parameters. Quantification of specific ventilation is achieved by correlating the time-course of signal intensity for each lung voxel with a library of simulated responses to the air/oxygen stimulus. SVI estimations of specific ventilation heterogeneity have been validated against multiple breath washout and proved to accurately determine the heterogeneity of the specific ventilation distribution.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Quantitative analysis of permeability for glioma grading using dynamic contrast-enhanced magnetic resonance imaging
    Zhao, Ming
    Guo, Li-Li
    Huang, Ning
    Wu, Qiong
    Zhou, Li
    Zhao, Hui
    Zhang, Jing
    Fu, Kuang
    ONCOLOGY LETTERS, 2017, 14 (05) : 5418 - 5426
  • [32] Comparison of aerosolized gadoteridol and gadopentetate dimeglumine for magnetic resonance ventilation imaging of the lung
    Haage, P
    Karaagac, S
    Adam, G
    Glowinski, A
    Günther, RW
    MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (04) : 803 - 806
  • [33] Simultaneous cardiac and respiratory synchronization in oxygen-enhanced magnetic resonance imaging of the lung using a pneumotachograph for respiratory monitoring
    Molinari, F
    Gaudino, S
    Fink, C
    Corbo, GM
    Valente, S
    Pirronti, T
    Bonomo, L
    INVESTIGATIVE RADIOLOGY, 2006, 41 (05) : 476 - 484
  • [34] Quantitative multivolume proton-magnetic resonance imaging in patients with cystic fibrosis lung disease: comparison with clinical indicators
    Pennati, Francesca
    Salito, Caterina
    Borzani, Irene
    Cervellin, Giulia
    Gambazza, Simone
    Guarise, Riccardo
    Russo, Maria Chiara
    Colombo, Carla
    Aliverti, Andrea
    EUROPEAN RESPIRATORY JOURNAL, 2019, 53 (05)
  • [35] Using fluorescently-labeled magnetic nanocomposites as a dual contrast agent for optical and magnetic resonance imaging
    Zhu, Taofeng
    Ma, Xiuqin
    Chen, Ruhua
    Ge, Zhijun
    Xu, Jun
    Shen, Xiaoke
    Jia, Lei
    Zhou, Tao
    Luo, Yifeng
    Ma, Tieliang
    BIOMATERIALS SCIENCE, 2017, 5 (06) : 1090 - 1100
  • [36] Oxygen challenge magnetic resonance imaging in healthy human volunteers
    Dani, Krishna A.
    Moreton, Fiona C.
    Santosh, Celestine
    Lopez, Rosario
    Brennan, David
    Schwarzbauer, Christian
    Goutcher, Colin
    O'Hare, Kevin
    Macrae, I. Mhairi
    Muir, Keith W.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2017, 37 (01) : 366 - 376
  • [37] Contrast agent-free functional magnetic resonance imaging with matrix pencil decomposition to quantify abnormalities in lung perfusion and ventilation in patients with cystic fibrosis
    Doellinger, Felix
    Bauman, Grzegorz
    Roehmel, Jobst
    Stahl, Mirjam
    Posch, Helena
    Steffen, Ingo G.
    Pusterla, Orso
    Bieri, Oliver
    Wielpuetz, Mark O.
    Mall, Marcus A.
    FRONTIERS IN MEDICINE, 2024, 11
  • [38] Modeling the Effect of Intra-Voxel Diffusion of Contrast Agent on the Quantitative Analysis of Dynamic Contrast Enhanced Magnetic Resonance Imaging
    Barnes, Stephanie L.
    Quarles, C. Chad
    Yankeelov, Thomas E.
    PLOS ONE, 2014, 9 (10):
  • [39] Dynamic oxygen-enhanced magnetic resonance imaging of the lung in asthma-Initial experience
    Zhang, Wei-Juan
    Niven, Robert M.
    Young, Simon S.
    Liu, Yu-Zhen
    Parker, Geoffrey J. M.
    Naish, Josephine H.
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (02) : 318 - 326
  • [40] Simultaneous magnetic resonance imaging of ventilation distribution and gas uptake in the human lung using hyperpolarized xenon-129
    Mugler, John P., III
    Altes, Talissa A.
    Ruset, Iulian C.
    Dregely, Isabel M.
    Mata, Jaime F.
    Miller, G. Wilson
    Ketel, Stephen
    Ketel, Jeffrey
    Hersman, F. William
    Ruppert, Kai
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2010, 107 (50) : 21707 - 21712