High performance liquid chromatography - tandem mass spectrometric determination of cyclovirobuxine D in human plasma

被引:4
|
作者
Yu, Peng [1 ]
Zou, Limin [1 ]
Liu, Wenying [1 ]
Wu, Chunyong [1 ]
Sun, Di [1 ]
Xu, Jihua [1 ]
Rao, Jinhua [1 ]
Yang, Qian [1 ]
机构
[1] China Pharmaceut Univ, Dept Pharmaceut Anal, Nanjing 210009, Peoples R China
关键词
cyclovirobuxine D; LC/MS/MS; human plasma; pharmacokinetic study;
D O I
10.1016/j.jpba.2006.04.025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive, specific and rapid high performance liquid chromatography-tandem mass spectrometric (LC/MS/MS) method for the determination of cyclovirobuxine D in human plasma was developed and validated. The triple-quadrupole tandem mass spectrometric detector with an electrospray interface (ESI) was operated under the selected reaction monitoring (SRM) mode. After the addition of citalopram as an internal standard (IS), plasma samples were extracted with ethyl acetate. Chromatographic separation of the analytes was performed on a Kromasil CN column with a mobile phase of methanol/water (88/12, v/v) containing 0.4% formic acid. Linearity was established for the range of concentration 0.2-40 ng/ml. Under optimized conditions, the mean recovery was 86.6%. The intra-day precision ranged from 4.56% to 7.81%, while the intra-day accuracy ranged from 2.75% to 11.0%. The inter-day precision was in the range 3.87-10.7%, and the inter-day accuracy was in the range -4.00% to 2.50%. The cyclovirobuxine D was stable in human plasma after three freeze-thaw cycles, under storage at room temperature for 12 h, in a freezer at -20 degrees C for 15 days and during processing (in autosampler) at 10 degrees C for 24 h. The validated method is suitable for quantitative determination of cyclovirobuxine D in human plasma in pharmacokinetics study and has been successfully applied to the analysis of clinical samples. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:488 / 493
页数:6
相关论文
共 50 条
  • [31] Liquid chromatography–mass spectrometric determination of plasmalogens in human plasma
    Shu-Ping Hui
    Hitoshi Chiba
    Takao Kurosawa
    Analytical and Bioanalytical Chemistry, 2011, 400 : 1923 - 1931
  • [32] Liquid Chromatography Tandem Mass Spectrometric Assay for the Determination of Forskolin in Rat Plasma
    Guo Ji-Fen
    Lu Bing
    Meng Fan-Hua
    Zhao Yi-Min
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (03) : 399 - 402
  • [33] High-performance liquid chromatographic-tandem mass spectrometric method for the determination of clemastine in human plasma
    Horváth, V
    Tolokán, A
    Egresi, A
    Pap, T
    Horvai, G
    Balogh-Nernes, K
    Klebovich, I
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 816 (1-2): : 153 - 159
  • [34] Liquid chromatographic tandem mass spectrometric determination of trandolapril in human plasma
    Pistos, C
    Koutsopoulou, M
    Panderi, I
    ANALYTICA CHIMICA ACTA, 2005, 540 (02) : 375 - 382
  • [35] Simultaneous determination of unlabeled and deuterium-labeled indinavir in human plasma by high-performance liquid chromatography with tandem mass spectrometric detection
    Woolf, EJ
    Matuszewski, BK
    JOURNAL OF PHARMACEUTICAL SCIENCES, 1997, 86 (02) : 193 - 198
  • [36] A high-performance liquid chromatography-tandem mass spectrometric method for the determination of pharmacokinetics of ganaxolone in rat, monkey, dog and human plasma
    Ramu, K
    Lam, GN
    Chien, B
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2001, 751 (01): : 49 - 59
  • [37] High sensitivity high performance liquid chromatography electrospray tandem mass spectrometry determination of terfenadine in human plasma
    Lau, YY
    Anderson, PH
    Talaat, R
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1996, 19 (16) : 2669 - 2679
  • [38] Development and Validation of a Rapid High-Performance Liquid Chromatography-Tandem Mass Spectrometric Method for Determination of Folic Acid in Human Plasma
    Zayed, Aref
    Bustami, Rana
    Alabsi, Wafaa
    El-Elimat, Tamam
    PHARMACEUTICALS, 2018, 11 (02)
  • [39] Determination of repaglinide in human plasma by high-performance liquid chromatography-tandem mass spectrometry
    Zhang, Jie
    Gao, Feng
    Guan, Xin
    Sun, Yan-tong
    Gu, Jing-kai
    Fawcett, J. Paul
    ACTA PHARMACEUTICA SINICA B, 2011, 1 (01) : 40 - 45
  • [40] Rapid determination of lenalidomide in rat plasma by an ultra performance liquid chromatography/tandem mass spectrometric method
    Krishna Pocha
    G. Devala Rao
    Medicinal Chemistry Research, 2015, 24 : 459 - 467