Detection of architectural distortion in mammograms using geometrical properties of thinned edge structures

被引:4
|
作者
Lakshmanan, Rekha [1 ]
Shiji, T. P. [1 ]
Jacob, Suma Mariam [2 ]
Pratab, Thara [2 ]
Thomas, Chinchu [3 ]
Thomas, Vinu [1 ]
机构
[1] Govt Model Engn Coll, Dept Elect Engn, Kochi, Kerala, India
[2] Lakeshore Hosp, Kochi, India
[3] Govt Engn Coll, Dept Elect Engn, Cherthala, India
关键词
Architectural distortion; breast cancer; classification; cuckoo search; geometrical properties of edge; structures; mammogram; pectoral muscle; sensitivity; specificity; PECTORAL MUSCLE; AUTOMATIC DETECTION; IMAGES;
D O I
10.1080/10798587.2017.1257544
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The proposed method detects the most commonly missed breast cancer symptom, Architectural Distortion. The basis of the method lies in the analysis of geometrical properties of abnormal patterns that correspond to Architectural Distortion in mammograms. Pre-processing methods are employed for the elimination of Pectoral Muscle (PM) region from the mammogram and to localize possible centers of Architectural Distortion. Regions that are candidates to contain centroids of Architectural Distortion are identified using a modification of the isotropic SUSAN filter. Edge features are computed in these regions using Phase Congruency, which are thinned using Gradient Magnitude Maximization. From these thinned edges, relevant edge structures are retained based on three geometric properties namely eccentricity to retain near linear structures, perpendicular distance from each such structure to the centroid of the edges and quadrant support membership of these edge structures. Features for classification are generated from these three properties; a feed-forward neural network, trained using a combination of backpropagation and a metaheuristic algorithm based on Cuckoo search, is employed for classifying the suspicious regions identified by the modified filter for Architectural Distortion, as normal or malignant. Experimental analyses were carried out on mammograms obtained from the standard databases MIAS and DDSM as well as on images obtained from Lakeshore Hospital in Kochi, India. The classification step yielded a sensitivity of 89%, 89.8.7% and 97.6% and specificity of 90.9, 85 and 96.7% on 60 images from MIAS, 100 images from DDSM database and 100 images from Lakeshore Hospital respectively
引用
收藏
页码:183 / 197
页数:15
相关论文
共 43 条
  • [21] Computer-aided detection of architectural distortion in prior mammograms of interval cancer
    Banik, Shantanu
    Rangayyan, Rangaraj M.
    Leo Desautels, J.E.
    Synthesis Lectures on Biomedical Engineering, 2013, 47 : 1 - 193
  • [22] Detection method for architectural distortion based on analysis of structure of mammary gland on mammograms
    Matsubara, T
    Fukuoka, D
    Yagi, N
    Hara, T
    Fujita, H
    Inenaga, Y
    Kasai, S
    Kano, A
    Endo, T
    Iwase, T
    CARS 2005: Computer Assisted Radiology and Surgery, 2005, 1281 : 1036 - 1040
  • [23] Reduction of false positives in the detection of architectural distortion in mammograms by using a geometrically constrained phase portrait model
    Fábio J. Ayres
    Rangaraj M. Rangayyan
    International Journal of Computer Assisted Radiology and Surgery, 2007, 1 : 361 - 369
  • [24] A pilot study of architectural distortion detection in mammograms based on characteristics of line shadows
    Mitsutaka Nemoto
    Soshi Honmura
    Akinobu Shimizu
    Daisuke Furukawa
    Hidefumi Kobatake
    Shigeru Nawano
    International Journal of Computer Assisted Radiology and Surgery, 2009, 4 : 27 - 36
  • [25] A computer-aided detection of the architectural distortion in digital mammograms using the fractal dimension measurements of BEMD
    Zyout, Imad
    Togneri, Roberto
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2018, 70 : 173 - 184
  • [26] A Hybrid Detection Scheme of Architectural Distortion in Mammograms Using Iris Filter and Gabor Filter
    Yamazaki, Mizuki
    Teramoto, Atsushi
    Fujita, Hiroshi
    BREAST IMAGING, IWDM 2016, 2016, 9699 : 174 - 182
  • [27] Detecting Architectural Distortion in Mammograms Using a Gabor Filtered Probability Map Algorithm
    Ejofodomi, O'tega
    Olawuyi, Michael
    Onyishi, Don Uche
    Ofualagba, Godswill
    ARTIFICIAL INTELLIGENCE APPLICATIONS AND INNOVATIONS, AIAI 2013, 2013, 412 : 328 - 335
  • [28] DOMAIN SPECIFIC CONVOLUTIONAL NEURAL NETS FOR DETECTION OF ARCHITECTURAL DISTORTION IN MAMMOGRAMS
    Ben-Ari, Rami
    Akselrod-Ballin, Ayelet
    Karlinsky, Leonid
    Hashoul, Sharbell
    2017 IEEE 14TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2017), 2017, : 552 - 556
  • [29] Detection of architectural distortion in prior screening mammograms using Gabor filters, phase portraits, fractal dimension, and texture analysis
    Rangayyan, Rangaraj M.
    Prajna, Shormistha
    Ayres, Fabio J.
    Desautels, J. E. Leo
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2008, 2 (06) : 347 - 361
  • [30] Detection of architectural distortion in prior screening mammograms using Gabor filters, phase portraits, fractal dimension, and texture analysis
    Rangaraj M. Rangayyan
    Shormistha Prajna
    Fábio J. Ayres
    J. E. Leo Desautels
    International Journal of Computer Assisted Radiology and Surgery, 2008, 2 : 347 - 361