A simple, highly sensitive and stable electrochemical sensor for the detection of quercetin in solution, onion and honey buckwheat using zinc oxide supported on carbon nanosheet (ZnO/CNS/MCPE) modified carbon paste electrode

被引:39
作者
Saritha, D. [1 ]
Koirala, A. R. [2 ]
Venu, M. [1 ]
Reddy, G. Dinneswara [2 ]
Reddy, A. Vijaya Bhaskar [3 ]
Sitaram, B. [2 ]
Madhavi, G. [1 ]
Aruna, K. [4 ]
机构
[1] Sri Venkateswara Univ, Dept Chem, Electrochem Res Lab, Tirupati 517502, Andhra Pradesh, India
[2] Sogang Univ, Dept Chem, Korea Ctr Artificial Photosynth, Seoul 121742, South Korea
[3] Univ Teknol PETRONAS, Ctr Res Ion Liquids, Seri Iskandar 32610, Perak, Malaysia
[4] Govt Degree Coll, Dept Chem, Nagiri Chittoor, Andhra Pradesh, India
关键词
Quercetin; Electrochemical sensor; Modified carbon paste electrode; Zinc oxide; Flavonol; SOLID-PHASE EXTRACTION; ZNO NANOPARTICLES; ASCORBIC-ACID; FOOD SOURCES; POLYPHENOLS; FLAVONOIDS; COMPOSITE; SPHERES; CHROMATOGRAPHY; DOPAMINE;
D O I
10.1016/j.electacta.2019.04.188
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Quercetin is one of the most biologically active flavonols, and great attention has been paid for its detection in a variety of natural products over the few decades owing to its broad spectrum of applications. Herein, we have synthesized zinc oxide nanoparticles and carbon nanosheet separately, then the synthesized zinc oxide nanoparticles were dispersed uniformly into the carbon nanosheet, and finally, zinc oxide dispersed on carbon nanosheet modified carbon paste electrode (ZnO/CNS/MCPE) was fabricated. The prepared electrode is simple, highly sensitive, stable and cheaper for the detection of quercetin in standard solutions and real samples of onion and honey buckwheat. The scan rate optimization at ZnO/CNS/MCPE electrode showed electron-transfer co-efficient (alpha), electron-transfer number (n) and electrode reaction standard rate constants (Ks) as 1.13, 2.0 and 0.33 sec(-1) respectively. The electrochemical response for quercetin detection with ZnO/CNS/MCPE was greatly enhanced, which is about 8.0 times higher than the unmodified carbon paste electrode. The limit of detection and limit of quantification values were found to be 0.04 and 0.13 mu mol L-1 respectively. The relative standard deviation for the detection of 1.0 mmol L-1 quercetin in the standard solution for 10 successive cycles was found to be 1.76%. Compared to the other reported modified electrodes, the fabricated ZnO/CNS/MCPE has provided a superior electrochemical response, adequate selectivity and better sensitivity for the detection of quercetin in solution and real samples. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:523 / 531
页数:9
相关论文
共 53 条
  • [11] Kiranmai S, 2017, ANAL BIOANAL ELECTRO, V9, P154
  • [12] Kumar G. Vinod, 2015, INT J ELECTROCHEM SC, V10, P3657
  • [13] Kumar SS, 2013, INT NANO LETT, V3, DOI 10.1186/2228-5326-3-30
  • [14] Lamson D W, 2000, Altern Med Rev, V5, P196
  • [15] Lavanya M, 2015, ANAL BIOANAL ELECTRO, V7, P22
  • [16] Lavanya M, 2015, ANAL BIOANAL ELECTRO, V7, P555
  • [17] Dietary flavonols protect diabetic human lymphocytes against oxidative damage to DNA
    Lean, MEJ
    Noroozi, M
    Kelly, I
    Burns, J
    Talwar, D
    Sattar, N
    Crozier, A
    [J]. DIABETES, 1999, 48 (01) : 176 - 181
  • [18] Electrode modified with porous alumina microfibers as a highly sensitive electrochemical sensor for quercetin
    Li, Yaohua
    Huang, Wensheng
    [J]. ANALYTICAL METHODS, 2015, 7 (06) : 2537 - 2541
  • [19] One-step solvothermal synthesis of ZnO-carbon composite spheres containing different amounts of carbon and their use as visible light photocatalysts
    Lian, Suoyuan
    Huang, Hui
    Zhang, Jianming
    Kang, Zhenhui
    Liu, Yang
    [J]. SOLID STATE COMMUNICATIONS, 2013, 155 : 53 - 56
  • [20] Polyphenols:: food sources and bioavailability
    Manach, C
    Scalbert, A
    Morand, C
    Rémésy, C
    Jiménez, L
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 2004, 79 (05) : 727 - 747