Intercomparison campaign of spectroradiometers for a correct estimation of solar spectral irradiance: results and potential impact on photovoltaic devices calibration

被引:14
作者
Galleano, Roberto [1 ]
Zaaiman, Willem [1 ]
Virtuani, Alessandro [2 ]
Pavanello, Diego [1 ,2 ]
Morabito, Paolo [3 ]
Minuto, Alessandro [3 ]
Spena, Angelo [4 ]
Bartocci, Simona [4 ]
Fucci, Raffaele [5 ]
Leanza, Gianni [5 ]
Fasanaro, Daniela [6 ]
Catena, Mario [6 ]
机构
[1] ESTI, Renewable Energy Unit, IET, DG JRC,EC, Ispra, Italy
[2] SUPSI ISAAC, Canobbio, Switzerland
[3] RSE SpA, Milan, Italy
[4] Univ Roma Tor Vergata, Dept Enterprise Engn, FTA Lab, Rome, Italy
[5] ENEA, UTTP FOTO Port, Rome, Italy
[6] Enel Ingn & Innovaz SpA, Catania, Italy
来源
PROGRESS IN PHOTOVOLTAICS | 2014年 / 22卷 / 11期
关键词
spectroradiometers; intercomparison; solar spectral irradiance; PV devices calibration;
D O I
10.1002/pip.2361
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper describes the results of an intercomparison of spectroradiometers for global and direct normal incidence irradiance in the visible and near-infrared spectral regions together with an assessment of the impact these results may have on the estimation of the short-circuit current (I-SC) calibration of photovoltaic devices and on the spectral mismatch calculation. The intercomparison was conducted in the framework of the European project Apollon with the additional participation of external partners from the Italian project for the long-term monitoring of solar radiation for photovoltaics. Six institutions and six spectroradiometer systems, representing different technologies and manufacturers, were involved. Prior to the intercomparison, all participating partners calibrated their own instrument(s) according to their usual procedures in order to verify the entire measuring and traceability chain. The difference in measured spectra shape and amplitude showed to have an impact on I-SC calculation of less than 3% and less than 6% for single-junction and multi-junction devices, respectively. When only the shape of the spectra is considered, the spectral mismatch ranges from 1.7% to 4.7% depending on the spectral response of the device. Copyright (c) 2013 John Wiley & Sons, Ltd.
引用
收藏
页码:1128 / 1137
页数:10
相关论文
共 17 条
  • [1] [Anonymous], 2006, 91 IOM
  • [2] [Anonymous], 6094043 ISOIEC
  • [3] [Anonymous], 2007, M39 ESTI
  • [4] [Anonymous], 609043 IEC
  • [5] [Anonymous], 2008, G17303 ASTM INT, DOI [10.1520/G0173-03R08, DOI 10.1520/G0173-03R08]
  • [6] SUSPEN intercomparison of ultraviolet spectroradiometers
    Bais, AF
    Gardiner, BG
    Slaper, H
    Blumthaler, M
    Bernhard, G
    McKenzie, R
    Webb, AR
    Seckmeyer, G
    Kjeldstad, B
    Koskela, T
    Kirsch, PJ
    Gröbner, J
    Kerr, JB
    Kazadzis, S
    Leszczynski, K
    Wardle, D
    Josefsson, W
    Brogniez, C
    Gillotay, D
    Reinen, H
    Weihs, P
    Svenoe, T
    Eriksen, P
    Kuik, F
    Redondas, A
    [J]. JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2001, 106 (D12) : 12509 - 12525
  • [7] Galleano R, 2012, P 8 C CONC PHOT SYST
  • [8] Grobner J, 2007, REPORT PMOD WRC COST
  • [9] Gueymard C, 1995, FSECPF27195, P32922
  • [10] Parameterized transmittance model for direct beam and circumsolar spectral irradiance
    Gueymard, CA
    [J]. SOLAR ENERGY, 2001, 71 (05) : 325 - 346