Chronic performance of polyurethane catheters covalently coated with ATH complex: A rabbit jugular vein model

被引:39
作者
Klement, Petr [1 ]
Du, Ying Jun [1 ]
Berry, Leslie R. [1 ]
Tressel, Paul [1 ]
Chan, Anthony K. C. [1 ]
机构
[1] McMaster Univ, Henderson Res Ctr, Hamilton, ON L8V 1C3, Canada
关键词
anticoagulant; antithrombin; heparin; polyurethane; surface grafting;
D O I
10.1016/j.biomaterials.2006.05.005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Covalent complexes of antithrombin (AT) and heparin (ATH) have superb anticoagulant activity towards thrombin and factor Xa. Stability of polyurethane central venous catheters covalently modified with radiolabeled ATH was studied using a roller pump with saline or protease P-5147. Saline wash removed loosely bound ATH molecules to decrease graft density from 26 to 12pmol/cm(2). However, only slightly more ATH was removed by strong protease (from 12 to 7 pmol/cm(2)). To evaluate ATH-coated, heparin-coated, and uncoated catheters, a chronic rabbit jugular vein model was developed with catheters maintained for up to 30-106 days. Lumen occlusion was tested by drawing blood twice daily. Although unmodified or heparin-coated catheters occluded within 5-7 days after insertion, all ATH catheters remained patent throughout the experiment. Scanning electron microscopy (SEM) analysis of heparin and uncoated catheters revealed extensive thrombosis (lumen + mural) while ATH catheters were unaffected. Visual observation showed significant deposition of protein and cells on control and heparin-modified catheters and, to a lesser degree, on ATH-coated surfaces. SEM showed no fibrin inside or outside of ATH catheters, which remained patent in extended studies out to 106 days. Although atomic force microscopy showed ATH coatings to be rough, 6-fold higher anti-factor Xa activity likely contributed to increased patency. Our data confirm that ATH-modified catheters are stable and have superior potency compared to heparin or control catheters. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:5107 / 5117
页数:11
相关论文
共 37 条
  • [1] In vitro blood compatibility of surface-modified polyurethanes
    Bernacca, GM
    Gulbransen, MJ
    Wilkinson, R
    Wheatley, DJ
    [J]. BIOMATERIALS, 1998, 19 (13) : 1151 - 1165
  • [2] Investigation of the anticoagulant mechanisms of a covalent antithrombin-heparin complex
    Berry, L
    Stafford, A
    Fredenburgh, J
    O'Brodovich, H
    Mitchell, L
    Weitz, J
    Andrew, M
    Chan, AKC
    [J]. JOURNAL OF BIOLOGICAL CHEMISTRY, 1998, 273 (52) : 34730 - 34736
  • [3] Exploiting the current paradigm of blood-material interactions for the rational design of blood-compatible materials
    Brash, JL
    [J]. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2000, 11 (11) : 1135 - 1146
  • [4] Covalent antithrombin-heparin complexes with high anticoagulant activity - Intravenous, subcutaneous, and intratracheal administration
    Chan, A
    Berry, L
    OBrodovich, H
    Klement, P
    Mitchell, L
    Baranowski, B
    Monagle, P
    Andrew, M
    [J]. JOURNAL OF BIOLOGICAL CHEMISTRY, 1997, 272 (35) : 22111 - 22117
  • [5] CHAN AK, 2002, T SOC BIOMATER, V25, P149
  • [6] Chan AKC, 2002, THROMB HAEMOSTASIS, V87, P606
  • [7] Delivery of LMW heparin via surface coated chitosan/peg-alginate microspheres prevents thrombosis
    Chandy, T
    Rao, GHR
    Wilson, RF
    Das, GS
    [J]. DRUG DELIVERY, 2002, 9 (02) : 87 - 96
  • [8] Is there an alternative to systemic anticoagulation, as related to interventional biomedical devices?
    Conn, Gemma
    Kidane, Asmeret G.
    Punshon, Geoffrey
    Kannan, Ruben Y.
    Hamilton, George
    Seifalian, Alexander M.
    [J]. EXPERT REVIEW OF MEDICAL DEVICES, 2006, 3 (02) : 245 - 261
  • [9] ANTICOAGULANT ACTION OF HEPARIN
    DAMUS, PS
    HICKS, M
    ROSENBERG, RD
    [J]. NATURE, 1973, 246 (5432) : 355 - 357
  • [10] In vivo rabbit acute model tests of polyurethane catheters coated with a novel antithrombin-heparin covalent complex
    Du, YJ
    Klement, P
    Berry, LR
    Tressel, P
    Chan, AKC
    [J]. THROMBOSIS AND HAEMOSTASIS, 2005, 94 (02) : 366 - 372