Validity of intraoperative imageless navigation (Naviswiss) for component positioning accuracy in primary total hip arthroplasty: protocol for a prospective observational cohort study in a single-surgeon practice

被引:10
作者
Ektas, Nalan [1 ]
Scholes, Corey [1 ]
Ruiz, Alejandro M. [2 ]
Ireland, John [3 ,4 ]
机构
[1] EBM Analyt, Sydney, NSW, Australia
[2] Act Surg, Sydney, NSW, Australia
[3] Sydney Bone & Joint Clin, Sydney, NSW, Australia
[4] Univ Wollongong, Sch Med, Wollongong, NSW, Australia
来源
BMJ OPEN | 2020年 / 10卷 / 10期
关键词
hip; orthopaedic & trauma surgery; adult orthopaedics; musculoskeletal disorders; ACETABULAR COMPONENT; COMPUTER NAVIGATION; LEG LENGTH; OFFSET; RELIABILITY;
D O I
10.1136/bmjopen-2020-037126
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Optimal outcomes in total hip arthroplasty (THA) are dependent on appropriate placement of femoral and acetabular components, with technological advances providing a platform for guiding component placement to reduce the risk of malpositioned components during surgery. This study will validate the intraoperative data captured using a handheld imageless THA navigation system against postoperative measurements of acetabular inclination, acetabular version, leg length and femoral offset on CT radiographs. Methods and analysis This is a prospective observational cohort study conducted within a single-centre, single-surgeon private practice. Data will be collected for 35 consecutive patients (>18 years) undergoing elective THA surgery, from the research registry established at the surgeon's practice. The primary outcome is the agreement between intraoperative component positioning data captured by the navigation system compared with postoperative measurements using CT. A total of ten CT scans will be reassessed for interobserver and intraobserver reliability. The influence of patient and surgical factors on the accuracy of component position will also be examined with multivariable linear regression. Ethics and dissemination Ethics approval for this study was provided through a certified ethics committee (Bellberry HREC approval number 2017-07-499). The results of this study will be disseminated through peer-reviewed journals and conference presentations.
引用
收藏
页数:7
相关论文
共 26 条
[1]   Computer navigation of the acetabular component in total hip arthroplasty: a narrative review [J].
Davenport, Dominic ;
Kavarthapu, Venu .
EFORT OPEN REVIEWS, 2016, 1 (07) :279-285
[2]   Accuracy of Component Positioning in 1980 Total Hip Arthroplasties: A Comparative Analysis by Surgical Technique and Mode of Guidance [J].
Domb, Benjamin G. ;
Redmond, John M. ;
Louis, Steven S. ;
Alden, Kris J. ;
Daley, Robert J. ;
LaReau, Justin M. ;
Petrakos, Alexandra E. ;
Gui, Chengcheng ;
Suarez-Ahedo, Carlos .
JOURNAL OF ARTHROPLASTY, 2015, 30 (12) :2208-2218
[3]   Comparison of Robotic-assisted and Conventional Acetabular Cup Placement in THA: A Matched-pair Controlled Study [J].
Domb, Benjamin G. ;
El Bitar, Youssef F. ;
Sadik, Adam Y. ;
Stake, Christine E. ;
Botser, Itamar B. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (01) :329-336
[4]   Precision and bias of imageless computer navigation and surgeon estimates for acetabular component position [J].
Dorr, Lawrence A. ;
Malik, Aamer ;
Wan, Zhinian ;
Long, William T. ;
Harris, Michael .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (465) :92-99
[5]   Lower limb length and offset in total hip arthroplasty [J].
Flecher, X. ;
Ollivier, M. ;
Argenson, J. N. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2016, 102 (01) :S9-S20
[6]  
Grosso Paul, 2016, Open Orthop J, V10, P490
[7]   Accounting for measurement error: A critical but often overlooked process [J].
Harris, Edwayd F. ;
Smith, Richayd N. .
ARCHIVES OF ORAL BIOLOGY, 2009, 54 :S107-S117
[8]   Evaluation of the accuracy of acetabular cup orientation using the accelerometer-based portable navigation system [J].
Hayashi, Shinya ;
Hashimoto, Shingo ;
Takayama, Koji ;
Matsumoto, Tomoyuki ;
Kamenaga, Tomoyuki ;
Fujishiro, Takaaki ;
Hiranaka, Takafumi ;
Niikura, Takahiro ;
Kuroda, Ryosuke .
JOURNAL OF ORTHOPAEDIC SCIENCE, 2020, 25 (04) :612-617
[9]   Imageless navigation for insertion of the acetabular component in total hip arthroplasty -: Is it as accurate as CT-based navigation? [J].
Kalteis, T ;
Handel, A ;
Bäthis, H ;
Perlick, L ;
Tingart, M ;
Grifka, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (02) :163-167
[10]   Accuracy of cup orientation and learning curve of the accelerometer-based portable navigation system for total hip arthroplasty in the supine position [J].
Kamenaga, Tomoyuki ;
Hayashi, Shinya ;
Hashimoto, Shingo ;
Matsumoto, Tomoyuki ;
Takayama, Koji ;
Fujishiro, Takaaki ;
Hiranaka, Takafumi ;
Niikura, Takahiro ;
Kuroda, Ryosuke .
JOURNAL OF ORTHOPAEDIC SURGERY, 2019, 27 (02)