Technetium-99m tetrofosmin rest/stress myocardial SPET with a same-day 2-hour protocol: Comparison with coronary angiography - A Spanish-Portuguese multicentre clinical trial

被引:10
|
作者
Montz, R
PerezCastejon, MJ
Jurado, JA
MartinComin, J
Esplugues, E
Salgado, L
Ventosa, A
Cantinho, G
Sa, EP
Fonseca, AT
Vieira, MR
OrtizBerrocal, J
Tabuenca, MJ
Garcia, A
Magrina, J
Ortega, D
Puente, C
Ferrer, AI
Pedrosa, J
Latre, JM
Carreras, JL
机构
[1] INST CARDIOL,MADRID,SPAIN
[2] INST CARDIOL,MADRID,SPAIN
[3] BELLVITGE HOSP,BARCELONA,SPAIN
[4] HOSP SANTA MARIA,FAC MED,LISBON,PORTUGAL
[5] INST PORTUGUES ONCOL FRANCISCO GENTIL,IPOFG,LISBON,PORTUGAL
[6] CLIN PUERTA HIERRO,MADRID,SPAIN
[7] HOSP CLIN BARCELONA,BARCELONA,SPAIN
[8] HOSP GEN VALLE HEBRON,BARCELONA,SPAIN
[9] HOSP REG CARLOS HAYA,MALAGA,SPAIN
[10] UNIV HOSP,COIMBRA,PORTUGAL
[11] HOSP REINA SOFIA,CORDOBA,SPAIN
来源
EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1996年 / 23卷 / 06期
关键词
myocardial perfusion single-photon emission tomography; coronary angiography; technetium-99m tetrofosmin; same-day 2-hour rest/stress protocol; coronary artery disease;
D O I
10.1007/BF00834525
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Technetium-99m tetrofosmin (Myoview) has unique properties for myocardial perfusion imaging very early after injection of the tracer. We used a very short same-day rest/stress protocol, to be performed within 2 h and evaluated its diagnostic accuracy. The study included 144 patients from seven Spanish and four Portuguese centres with a diagnosis of uncomplicated coronary artery disease (CAD); 78 patients (54%) had no history of prior myocardial infarction, Patients were injected with less than or equal to 300 MBq Tc-99m-tetrofosmin at rest and less than or equal to 900 MBq approximately 1 h later at peak exercise, Single-photon emission tomographic (SPET) acquisitions were initiated within 5-30 min post injection. The results were compared with those of coronary angiography (CA). The data of 142 patients were completely evaluable (two with non-evaluable images were excluded). The quality of rest images was excellent or good in 86%, regionally problematic in 7%, poor but well interpretable in 5% and non-evaluable in 2%. The overall sensitivity for the detection of CAD was 93%, the specificity 38% and the accuracy 85%, The localization of defects by SPET in relation to the perfusion territories of stenosed vessels (greater than or equal to 50%) was achieved with a sensitivity of 64% for the left anterior descending artery, 49% for the left circumflex artery and 86% for the right coronary artery, and an accuracy of 71%, 72% and 73% respectively. Concordance of SPET and CA was 62% for single-vessel dis ease and 68% for multivessel disease. In conclusion, this Spanish-Portuguese multicentre clinical trial confirmed, in a considerable number of patients who underwent coronary angiography, the feasibility of Tc-99m tetrofosmin (Myoview) rest/stress myocardial SPET using a very short protocol (2 h).
引用
收藏
页码:639 / 647
页数:9
相关论文
共 1 条
  • [1] MULTICENTER TRIAL VALIDATION FOR QUANTITATIVE-ANALYSIS OF SAME-DAY REST-STRESS TECHNETIUM-99M-SESTAMIBI MYOCARDIAL TOMOGRAMS
    VANTRAIN, KF
    GARCIA, EV
    MADDAHI, J
    AREEDA, J
    COOKE, CD
    KIAT, H
    SILAGAN, G
    FOLKS, R
    FRIEDMAN, J
    MATZER, L
    GERMANO, G
    BATEMAN, T
    ZIFFER, J
    DEPUEY, EG
    FINKBENNETT, D
    CLONINGER, K
    BERMAN, DS
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (04) : 609 - 618