Gray blood late gadolinium enhancement cardiovascular magnetic resonance for improved detection of myocardial scar

被引:31
作者
Fahmy, Ahmed S. [1 ,2 ,3 ]
Neisius, Ulf [1 ,2 ]
Tsao, Connie W. [1 ,2 ]
Berg, Sophie [1 ,2 ]
Goddu, Elizabeth [1 ,2 ]
Pierce, Patrick [1 ,2 ]
Basha, Tamer A. [3 ]
Ngo, Long [2 ,4 ]
Manning, Warren J. [1 ,2 ,5 ]
Nezafat, Reza [1 ,2 ]
机构
[1] Beth Israel Deaconess Med Ctr, Cardiovasc Div, Dept Med, 330 Brookline Ave, Boston, MA 02215 USA
[2] Harvard Med Sch, 330 Brookline Ave, Boston, MA 02215 USA
[3] Cairo Univ, Sch Engn, Biomed Engn Dept, Giza, Egypt
[4] Beth Israel Deaconess Med Ctr, Dept Med, Div Gen Med & Primary Care, Boston, MA 02215 USA
[5] Beth Israel Deaconess Med Ctr, Dept Radiol, 330 Brookline Ave, Boston, MA 02215 USA
基金
美国国家卫生研究院;
关键词
Late gadolinium enhancement; Blood suppression; Myocardial viability; Myocardial infarction; INVERSION-RECOVERY; CARDIAC MR; INFARCTION; HYPERENHANCEMENT;
D O I
10.1186/s12968-018-0442-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Low scar-to-blood contrast in late gadolinium enhanced (LGE) MRI limits the visualization of scars adjacent to the blood pool. Nulling the blood signal improves scar detection but results in lack of contrast between myocardium and blood, which makes clinical evaluation of LGE images more difficult. Methods: GB-LGE contrast is achieved through partial suppression of the blood signal using T-2 magnetization preparation between the inversion pulse and acquisition. The timing parameters of GB-LGE sequence are determined by optimizing a cost-function representing the desired tissue contrast. The proposed 3D GB-LGE sequence was evaluated using phantoms, human subjects (n = 45) and a swine model of myocardial infarction (n = 5). Two independent readers subjectively evaluated the image quality and ability to identify and localize scarring in GB-LGE compared to black-blood LGE (BB-LGE) (i.e., with complete blood nulling) and conventional (bright-blood) LGE. Results: GB-LGE contrast was successfully generated in phantoms and all in-vivo scans. The scar-to-blood contrast was improved in GB-LGE compared to conventional LGE in humans (1.1 +/- 0.5 vs. 0.6 +/- 0.4, P < 0.001) and in animals (1.5 +/- 0.2 vs. -0.03 +/- 0.2). In patients, GB-LGE detected more tissue scarring compared to BB-LGE and conventional LGE. The subjective scores of the GB-LGE ability for localizing LV scar and detecting papillary scar were improved as compared with both BB-LGE (P < 0.024) and conventional LGE (P < 0.001). In the swine infarction model, GB-LGE scores for the ability to localize LV scar scores were consistently higher than those of both BB-LGE and conventional-LGE. Conclusion: GB-LGE imaging improves the ability to identify and localize myocardial scarring compared to both BB-LGE and conventional LGE. Further studies are warranted to histologically validate GB-LGE.
引用
收藏
页数:11
相关论文
共 27 条
  • [1] Accelerated Late Gadolinium Enhancement Cardiac MR Imaging with Isotropic Spatial Resolution Using Compressed Sensing: Initial Experience1
    Akcakaya, Mehmet
    Rayatzadeh, Hussein
    Basha, Tamer A.
    Hong, Susie N.
    Chan, Raymond H.
    Kissinger, Kraig V.
    Hauser, Thomas H.
    Josephson, Mark E.
    Manning, Warren J.
    Nezafat, Reza
    [J]. RADIOLOGY, 2012, 264 (03) : 691 - 699
  • [2] Low-dimensional-Structure Self-Learning and Thresholding: Regularization Beyond Compressed Sensing for MRI Reconstruction
    Akcakaya, Mehmet
    Basha, Tamer A.
    Goddu, Beth
    Goepfert, Lois A.
    Kissinger, Kraig V.
    Tarokh, Vahid
    Manning, Warren J.
    Nezafat, Reza
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (03) : 756 - 767
  • [3] Black blood late gadolinium enhancement using combined T2 magnetization preparation and inversion recovery
    Tamer Basha
    Sébastien Roujol
    Kraig V Kissinger
    Beth Goddu
    Warren J Manning
    Reza Nezafat
    [J]. Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [4] Improved dark blood late gadolinium enhancement (DB-LGE) imaging using an optimized joint inversion preparation and T2 magnetization preparation
    Basha, Tamer A.
    Tang, Maxine C.
    Tsao, Connie
    Tschabrunn, Cory M.
    Anter, Elad
    Manning, Warren J.
    Nezafat, Reza
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (01) : 351 - 360
  • [5] Clinical Performance of High-Resolution Late Gadolinium Enhancement Imaging With Compressed Sensing
    Basha, Tamer A.
    Akcakaya, Mehmet
    Liew, Charlene
    Tsao, Connie W.
    Delling, Francesca N.
    Addae, Gifty
    Ngo, Long
    Manning, Warren J.
    Nezafat, Reza
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (06) : 1829 - 1838
  • [6] Improved Detection of Subendocardial Hyperenhancement in Myocardial Infarction Using Dark Blood-Pool Delayed Enhancement MRI
    Farrelly, Cormac
    Rehwald, Wolfgang
    Salerno, Michael
    Davarpanah, Amir
    Keeling, Aoife N.
    Jacobson, Jason T.
    Carr, James C.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (02) : 339 - 348
  • [7] Prospective comparison of novel dark blood late gadolinium enhancement with conventional bright blood imaging for the detection of scar
    Francis, Rohin
    Kellman, Peter
    Kotecha, Tushar
    Baggiano, Andrea
    Norrington, Karl
    Martinez-Naharro, Ana
    Nordin, Sabrina
    Knight, Daniel S.
    Rakhit, Roby D.
    Lockie, Tim
    Hawkins, Philip N.
    Moon, James C.
    Hausenloy, Derek J.
    Xue, Hui
    Hansen, Michael S.
    Fontana, Marianna
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2017, 19
  • [8] T2 quantification for improved detection of myocardial edema
    Giri, Shivraman
    Chung, Yiu-Cho
    Merchant, Ali
    Mihai, Georgeta
    Rajagopalan, Sanjay
    Raman, Subha V.
    Simonetti, Orlando P.
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2009, 11
  • [9] Evaluation of Papillary Muscle Function Using Cardiovascular Magnetic Resonance Imaging in Mitral Valve Prolapse
    Han, Yuchi
    Peters, Dana C.
    Kissinger, Kraig V.
    Goddu, Beth
    Yeon, Susan B.
    Manning, Warren J.
    Nezafat, Reza
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2010, 106 (02) : 243 - 248
  • [10] Dark-blood late gadolinium enhancement without additional magnetization preparation
    Holtackers, Robert J.
    Chiribiri, Amedeo
    Schneider, Torben
    Higgins, David M.
    Botnar, Rene M.
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2017, 19