摘要
Purpose: Cross-linking has proven effective in reducing polyethylene wear in total hip replacements. However, increasing the amount of cross-links will impair other mechanical properties of the polyethylene. The optimal threshold of crosslinking has still not been established. This led to the development of a moderately cross-linked (5 Mrad) cemented cup in which wear and stability is yet to be determined. Methods: A total of, 70 hips were included in this case series on the cemented Marathon (R) cup. Mean age of the patients was 78 years (SD 15). We measured wear and migration by radiostereometry at 3, 12 and 24 months. Results: The proximal wear rate estimate between 3 to 24 months was 0.036 mm/year, and a total proximal wear estimate at 2 years of 0.11 mm (95% CI 0.09-0.14). Translations and rotations along the 3 cardinal axes were all at or below the precision limit, and less than what is believed to be predictive of later loosening, namely 0.2-1 mm for proximal migration. The cups remained stable after the initial "bedding in" that occurred during the first 3 months. Conclusions: Our results indicate that moderate cross-linking (5Mrad) yields low wear and high stability in this specific acetabular cup, comparable to other cups with higher cross-linking.
引用
收藏
页码:199 / 203
页数:5
相关论文
共 27 条
  • [1] Role of polyethylene particles in peri-prosthetic osteolysis: A review
    Atkins, Gerald J.
    Haynes, David R.
    Howie, Donald W.
    Findlay, David M.
    [J]. WORLD JOURNAL OF ORTHOPEDICS, 2011, 2 (10): : 93 - 101
  • [2] Reduction of osteolysis with use of Marathon cross-linked polyethylene - A concise follow-up, at a minimum of five years, of a previous report
    Bitsch, Rudi G.
    Loidolt, Travis
    Heisel, Christian
    Ball, Scott
    Schmalzried, Thomas P.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (07) : 1487 - 1491
  • [3] Wear of a 5 Megarad Cross-linked Polyethylene Liner: A 6-year RSA Study
    Callary, Stuart A.
    Campbell, David G.
    Mercer, Graham
    Nilsson, Kjell G.
    Field, John R.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (07) : 2238 - 2244
  • [4] Campbell MJ, 2005, DESIGN STUDIES MED R, P40
  • [5] Comparison of cross-linked polyethylene materials for orthopaedic applications
    Collier, JP
    Currier, BH
    Kennedy, FE
    Currier, JH
    Timmins, GS
    Jackson, SK
    Brewer, RL
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (414) : 289 - 304
  • [6] Oxidation in orthopaedic UHMWPE sterilized by gamma-radiation and ethylene oxide
    Costa, L
    Luda, MP
    Trossarelli, L
    del Prever, EMB
    Crova, M
    Gallinaro, P
    [J]. BIOMATERIALS, 1998, 19 (7-9) : 659 - 668
  • [7] The Otto Aufranc Award -: Highly cross-linked polyethylene in Total Hip Arthroplasty -: Randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis
    Digas, G
    Kärrholm, J
    Thanner, J
    Malchau, H
    Herberts, P
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) : 6 - 16
  • [8] A literature review of the association between wear rate and osteolysis in total hip arthroplasty
    Dumbleton, JH
    Manley, MT
    Edidin, AA
    [J]. JOURNAL OF ARTHROPLASTY, 2002, 17 (05) : 649 - 661
  • [9] A Prospective, Randomized Study of Cross-Linked and Non-Cross-Linked Polyethylene for Total Hip Arthroplasty at 10-Year Follow-Up
    Engh, Charles A., Jr.
    Hopper, Robert H., Jr.
    Huynh, Cathy
    Ho, Henry
    Sritulanondha, Supatra
    Engh, Charles A., Sr.
    [J]. JOURNAL OF ARTHROPLASTY, 2012, 27 (08) : 2 - 7
  • [10] 18 years of results with cemented primary hip prostheses in the Norwegian Arthroplasty Register Concerns about some newer implants
    Espehaug, Birgitte
    Furnes, Ove
    Engesaeter, Lars B.
    Havelin, Leif I.
    [J]. ACTA ORTHOPAEDICA, 2009, 80 (04) : 402 - 412