Analysis of inlet and gap effect in hydrodynamics and mass transport performance of a multipurpose electrochemical reactor: CFD simulation and experimental validation

被引:20
作者
Rodriguez, A. [1 ,2 ]
Rivera, F. F. [3 ]
Orozco, G. [1 ]
Carreno, G. [4 ]
Castaneda, F. [1 ]
机构
[1] Ctr Invest & Desarrollo Tecnol Electroquim, Parque Tecnol Queretaro S-N, Pedro Escobedo 76703, Queretaro, Mexico
[2] Univ Politecn Santa Rosa Jauregui, Carretera Fed 57 Qro SLP Km 31-150, Santa Rosa Jauregui 76703, Queretaro, Mexico
[3] CONACYT Ctr Invest & Desarrolo Tecnol Electroquim, Parque Tecnol Queretaro S-N, Pedro Escobedo 76703, Queretaro, Mexico
[4] Univ Guanajuato, Dept Ingn Geomat & Hidraul, Juarez 77 Col Ctr, Guanajuato 36000, Guanajuato, Mexico
关键词
Monopolar electrochemical reactor; Experimental RTD validation; Experimental limiting current validation; Numerical simulation and experimental validation; FM01-LC REACTOR; FLOW; BEHAVIOR; ELECTROLYZER; CELL;
D O I
10.1016/j.electacta.2018.06.071
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
This work deals with the reaction environment analysis (hydrodynamic and mass transport characterization) inside the flow channel of a parallel plate electrolyzer. Different electrode gap and inlet configurations were tested using computational and experimental techniques. Computational methods are based on numerical solution of mathematical models that describe fluid dynamics inside reactor meanwhile, experimental characterization was carried out by means of residence time distribution (RTD) and limiting current tests. In order to evidence the phenomenological influence of hydrodynamic pattern generated by different design parameters, a 3-D diffusion-convection model was implemented taking into account the local velocity vectors obtained by solution of Navier-Stokes equations to obtain theoretical RTD and by diffusion-convection equation in order to describe hydrodynamics and overall mass transport performance. Average Re numbers considered in this work were between 102 <= Re <= 702, which are characteristic of a laminar flow regime. Velocity fields obtained by CFD analysis evidenced the existence of prominent jet flow zones, particularly when 45 degrees inlet angle is used. These effects diminished with 60 degrees inlet angle configuration. RTD analysis also showed important tailing, indicating presence of internal flow by-passing channeling effects. Mass flux distribution (associated with global mass transport coefficient and limiting current) obtained by CFD analysis evidenced the existence of non-homogeneous distribution provoked by the flow pattern inside of our reactor. From phenomenological point of view, the analysis carried out in this work, demonstrates that mass flux distribution is strongly influenced by geometric design parameters of a multipurpose parallel plate reactor. The higher mass transport coefficient was obtained with 7 mm of interelectrode gap and 60 degrees inlet angle configuration. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:520 / 532
页数:13
相关论文
共 36 条
  • [1] Pressure Drop through Platinized Titanium Porous Electrodes for Cerium-Based Redox Flow Batteries
    Arenas, Luis F.
    de Leon, Carlos Ponce
    Walsh, Frank C.
    [J]. AICHE JOURNAL, 2018, 64 (03) : 1135 - 1146
  • [2] Electrochemical removal of tin from dilute aqueous sulfate solutions using a rotating cylinder electrode of expanded metal
    Bazan, JC
    Bisang, JM
    [J]. JOURNAL OF APPLIED ELECTROCHEMISTRY, 2004, 34 (05) : 501 - 506
  • [3] Characterization and modeling of the hydrodynamic behavior in the filter-press-type FM01-LC electrochemical cell by direct flow visualization and residence time distribution
    Bengoa, C
    Montillet, A
    Legentilhomme, P
    Legrand, J
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2000, 39 (07) : 2199 - 2206
  • [4] Electro-Fenton Process and Related Electrochemical Technologies Based on Fenton's Reaction Chemistry
    Brillas, Enric
    Sires, Ignasi
    Oturan, Mehmet A.
    [J]. CHEMICAL REVIEWS, 2009, 109 (12) : 6570 - 6631
  • [5] STUDIES OF SPACE-AVERAGED MASS-TRANSPORT IN THE FM01-LC LABORATORY ELECTROLYZER
    BROWN, CJ
    PLETCHER, D
    WALSH, FC
    HAMMOND, JK
    ROBINSON, D
    [J]. JOURNAL OF APPLIED ELECTROCHEMISTRY, 1993, 23 (01) : 38 - 43
  • [6] A CFD Study with Analytical and Experimental Validation of Laminar and Turbulent Mass-Transfer in Electrochemical Reactors
    Colli, A. N.
    Bisang, J. M.
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2018, 165 (02) : E81 - E88
  • [7] Combination of Cumulative and Convergent Flows as a Means to Improve the Uniformity of Tertiary Current Distribution in Parallel-Plate Electrochemical Reactors
    Colli, A. N.
    Bisang, J. M.
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (04) : E42 - E47
  • [8] Mass-transfer characterization in a parallel-plate electrochemical reactor with convergent flow
    Colli, A. N.
    Bisang, J. M.
    [J]. ELECTROCHIMICA ACTA, 2013, 113 : 575 - 582
  • [9] Mass-transfer studies in an electrochemical reactor with a small interelectrode gap
    Colli, A. N.
    Toelzer, R.
    Bergmann, M. E. H.
    Bisang, J. M.
    [J]. ELECTROCHIMICA ACTA, 2013, 100 : 78 - 84
  • [10] Validation of Theory with Experiments for Local Mass Transfer at Parallel Plate Electrodes under Laminar Flow Conditions
    Colli, A. N.
    Bisang, J. M.
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2013, 160 (01) : E5 - E11