Functional Design and Evaluation of Structural Firefighter Turnout Suits for Improved Thermal Comfort: Thermal Manikin and Physiological Modeling

被引:8
作者
McQuerry, Meredith [1 ]
Barker, Roger [2 ]
DenHartog, Emiel [2 ]
机构
[1] Florida State Univ, Retail Merchandising & Prod Dev Dept, Tallahassee, FL 32306 USA
[2] North Carolina State Univ, Coll Text, TPACC, Raleigh, NC USA
关键词
functional design; protective clothing; comfort; firefighter; heat loss;
D O I
10.1177/0887302X18757348
中图分类号
F [经济];
学科分类号
02 ;
摘要
Structural firefighter prototype designs incorporating ventilation, stretch, and modularity were developed following Watkins' functional design process. Prototypes were designed and manufactured, including single-layer, vented, stretch, and combination prototypes. Prototype garments were evaluated for improved thermal comfort and heat loss using sweating thermal manikin assessments in two conditions: static (standing still with no wind) and dynamic (walking with wind). Raw thermal and evaporative resistance data from the manikin testing were input into a thermal modeling software system (RadTherm (R)) and physiological responses (core temperature, skin temperature, and sweat rate) were predicted for each prototype. A significant improvement in heat loss was measured when ventilation openings and modularity were added to the design of the clothing system. The single-layer, vented, and combination prototypes also had significantly lower increases in predicted physiological responses.
引用
收藏
页码:165 / 179