Evaluation of right ventricular function using liver stiffness in patients with left ventricular assist device

被引:20
作者
Kashiyama, Noriyuki [1 ]
Toda, Koichi [1 ]
Nakamura, Teruya [1 ]
Miyagawa, Shigeru [1 ]
Nishi, Hiroyuki [2 ]
Yoshikawa, Yasushi [1 ]
Fukushima, Satsuki [1 ]
Saito, Shunsuke [1 ]
Yoshioka, Daisuke [1 ]
Sawa, Yoshiki [1 ]
机构
[1] Osaka Univ, Dept Cardiovasc Surg, Grad Sch Med, Osaka, Japan
[2] Osaka Police Hosp, Dept Cardiovasc Surg, Osaka, Japan
关键词
Circulatory support devices; Heart failure; Liver; Abdominal organs; ADVANCED HEART-FAILURE; TRANSIENT ELASTOGRAPHY; HEPATIC-FIBROSIS; SUPPORT; INSUFFICIENCY; IMPLANTATION;
D O I
10.1093/ejcts/ezw419
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: Although right ventricular failure (RVF) is a major concern after left ventricular assist device (LVAD) implantation, methodologies to evaluate RV function remain limited. Liver stiffness (LS), which is closely related to right-sided filling pressure and may indicate RVF severity, could be non-invasively and repeatedly assessed using transient elastography. Here we investigated the suitability of LS as a parameter of RV function in pre- and post-LVAD periods. METHODS: The study included 55 patients with LVAD implantation as a bridge to transplantation between 2011 and 2015 whose LS was assessed using transient elastography. RESULTS: Seventeen patients presented with RVF, defined as requiring inotropic support for >= 30 days, nitric oxygen inhalation for >= 5 days, and/or mechanical RV support following LVAD implantation. Survival of patients with RVF was significantly worse compared with that of patients without RVF. Multivariate logistic regression analysis identified preoperative LS, LV diastolic dimension, RV stroke work index, and dilated phase of hypertrophic cardiomyopathy aetiology as significant risk factors; the combination of these parameters could improve predictive power of post-LVAD RVF with areas under the curve of 0.89. Furthermore, LS was significantly decreased by LV unloading and significantly correlated with right-sided filling pressure. CONCLUSIONS: In addition to dilated hypertrophic cardiomyopathy aetiology, reduced RV stroke work index and small LV dimension, we demonstrated that non-invasively measured LS was a predictor of post-LVAD RVF and can be used as a parameter for the evaluation and optimization of RV function in the perioperative period.
引用
收藏
页码:715 / 721
页数:7
相关论文
共 20 条
[1]  
[Anonymous], J HEPATOL, DOI DOI 10.1016/J.JHEP.2011.02.023
[2]   Early planned institution of biventricular mechanical circulatory support results in improved outcomes compared with delayed conversion of a left ventricular assist device to a biventricular assist device [J].
Fitzpatrick, J. Raymond, III ;
Frederick, John R. ;
Hiesinger, William ;
Hsu, Vivian M. ;
McCormick, Ryan C. ;
Kozin, Elliott D. ;
Laporte, Carine M. ;
O'Hara, Mary Lou ;
Howell, Elan ;
Dougherty, Deborah ;
Cohen, Jeffrey E. ;
Southerland, Kevin W. ;
Howard, Jessica L. ;
Paulson, Carter ;
Acker, Michael A. ;
Morris, Rohinton J. ;
Woo, Y. Joseph .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (04) :971-977
[3]   Clinical Predictors of Hepatic Fibrosis in Chronic Advanced Heart Failure [J].
Gelow, Jill M. ;
Desai, Akshay S. ;
Hochberg, Claudia P. ;
Glickman, Jonathan N. ;
Givertz, Michael M. ;
Fang, James C. .
CIRCULATION-HEART FAILURE, 2010, 3 (01) :59-64
[4]   Impact of heart failure and changes to volume status on liver stiffness: non-invasive assessment using transient elastography [J].
Hopper, Ingrid ;
Kemp, William ;
Porapakkham, Pornwalee ;
Sata, Yusuke ;
Condon, Eilis ;
Skiba, Marina ;
Farber, Lauren ;
Porapakkham, Pramote ;
Williams, Trevor J. ;
Menahem, Solomon ;
Roberts, Stuart ;
Krum, Henry .
EUROPEAN JOURNAL OF HEART FAILURE, 2012, 14 (06) :621-627
[5]   Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: Incidence, risk factors, and effect on outcomes [J].
Kormos, Robert L. ;
Teuteberg, Jeffrey J. ;
Pagani, Francis D. ;
Russell, Stuart D. ;
John, Ranjit ;
Miller, Leslie W. ;
Massey, Todd ;
Milano, Carmelo A. ;
Moazami, Nader ;
Sundareswaran, Kartik S. ;
Farrar, David J. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 139 (05) :1316-1324
[6]   Liberal use of tricuspid-valve annuloplasty during left-ventricular assist device implantation [J].
Krishan, Kewal ;
Nair, Ajith ;
Pinney, Sean ;
Adams, David H. ;
Anyanwu, Anelechi C. .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 41 (01) :213-217
[7]   Right ventricular failure after left ventricular assist devices [J].
Lampert, Brent C. ;
Teuteberg, Jeffrey J. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (09) :1123-1130
[8]   Recommendations for Cardiac Chamber Quantification by Echocardiography in Adults: An Update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging [J].
Lang, Roberto M. ;
Badano, Luigi P. ;
Mor-Avi, Victor ;
Afilalo, Jonathan ;
Armstrong, Anderson ;
Ernande, Laura ;
Flachskampf, Frank A. ;
Foster, Elyse ;
Goldstein, Steven A. ;
Kuznetsova, Tatiana ;
Lancellotti, Patrizio ;
Muraru, Denisa ;
Picard, Michael H. ;
Rietzschel, Ernst R. ;
Rudski, Lawrence ;
Spencer, Kirk T. ;
Tsang, Wendy ;
Voigt, Jens-Uwe .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2015, 16 (03) :233-271
[9]   Liver Stiffness Is an Unreliable Marker of Liver Fibrosis in Patients with Cardiac Insufficiency [J].
Lebray, Pascal ;
Varnous, Shaida ;
Charlotte, Frederic ;
Varaut, Anne ;
Poynard, Thierry ;
Ratziu, Vlad .
HEPATOLOGY, 2008, 48 (06) :2089-2089
[10]   Hepatic dysfunction after left ventricular mechanical assist in patients with end-stage heart failure: Role of inflammatory response and hepatic microcirculation [J].
Masai, T ;
Sawa, Y ;
Ohtake, S ;
Nishida, T ;
Nishimura, M ;
Fukushima, N ;
Yamaguchi, T ;
Matsuda, H .
ANNALS OF THORACIC SURGERY, 2002, 73 (02) :549-555