共 31 条
Dynamic cascade-model-based frequency-scanning interferometry for real-time and rapid absolute optical ranging
被引:35
作者:
Deng, Zhongwen
[1
]
Liu, Zhigang
[1
]
Jia, Xingyu
[1
]
Deng, Wen
[1
]
Zhang, Xin
[1
]
机构:
[1] Xi An Jiao Tong Univ, Minist Educ, Key Lab Modern Design & Rotor Bearing Syst, Xian 710049, Shaanxi, Peoples R China
基金:
中国国家自然科学基金;
关键词:
DISTANCE MEASUREMENT SYSTEM;
SWEEPING INTERFEROMETRY;
KALMAN FILTER;
PRECISION;
IMPROVEMENT;
ACCURACY;
ERRORS;
D O I:
10.1364/OE.27.021929
中图分类号:
O43 [光学];
学科分类号:
070207 ;
0803 ;
摘要:
A new frequency-scanning interferometry (FSI) scheme using in-phase and quadrature (IQ) detection for real-time and rapid absolute optical ranging is presented. Dynamic measurement with FSI modulates interference signal frequency by both target movement and time-varying optical-frequency scanning rate; hence, a dynamic model is proposed to decouple dynamic absolute distance from the instantaneous frequency of interference signals. The unscented Kalman filter and particle filter algorithms are implemented for the nonlinear first-layer and non-Gaussian second-layer models, respectively. The proposed FSI scheme eliminates nonlinear optical-frequency scanning effects in dynamic measurements and realizes real-time measurement only current observed data are used. Experimental results verify high tracking performance for a vibrating target with approximately 10 mu m amplitude and 50-500 Hz frequency. (C) 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:21929 / 21945
页数:17
相关论文