Response of various LiF thermolumine scent detectors to high energy ions - Results of the ICCHIBAN experiment

被引:36
作者
Bilski, P. [1 ]
机构
[1] Polish Acad Sci, Inst Nucl Phys, Dept Radiat Phys & Dosimetry, PL-31342 Krakow, Poland
关键词
radiation dosimetry; thermoluminescence; high-LET radiation; lithium fluoride;
D O I
10.1016/j.nimb.2006.05.012
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Within the ICCHIBAN inter-comparison experiment organized at the HIMAC accelerator in Chiba, Japan, LiF:Mg,Ti (MTS-7, MTS-6 and MTT-7) and LiF:Mg,Cu,P (MCP-7) thermoluminescent detectors were exposed to beams of energetic He, C, Si, Ne, Fe, Ar and Kr ions. Several thousand thermoluminescent (TL) detectors of similar types were recently applied in the MATROSHKA space dosimetry experiment, where a humanoid phantom containing such detectors underwent an 18-month exposure outside the International Space Station. The ICCHIBAN project was designed to provide means of calibrating these detectors in high-LET fields. The energy of the ion beams ranged between 60 MeV/amu and 460 Mev/amu, and the corresponding ion LET values - between 2.2 keV/mu m and 595 keV/mu m (in water). For each ion specie the relative TL efficiency was evaluated. Interestingly, the measured relationship between relative TL efficiency and LET for these ions was found to follow unique trend lines. The efficiency of all types of LiF:Mg,Ti detectors exposed to energetic He ions was found to exceed efficiency for gamma-rays. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:121 / 126
页数:6
相关论文
共 12 条
[1]   Space radiation dosimetry in low-Earth orbit and beyond [J].
Benton, ER ;
Benton, E .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2001, 184 (1-2) :255-294
[2]  
BERGER T, 2005, 10 WORKSH RAD MON IN
[3]   LiF:Mg,Ti (MTT) TL detectors optimised for high-LET radiation dosimetry [J].
Bilski, P ;
Budzanowski, A ;
Olko, P ;
Mandowska, E .
RADIATION MEASUREMENTS, 2004, 38 (4-6) :427-430
[4]   THERMOLUMINESCENCE EFFICIENCY OF LIFMG,CU,P (MCP-N) DETECTORS TO PHOTONS, BETA-ELECTRONS, ALPHA-PARTICLES AND THERMAL-NEUTRONS [J].
BILSKI, P ;
OLKO, P ;
BURGKHARDT, B ;
PIESCH, E ;
WALIGORSKI, MPR .
RADIATION PROTECTION DOSIMETRY, 1994, 55 (01) :31-38
[5]   Optimisation of LiF:Mg,Ti detectors for dosimetry in proton radiotherapy [J].
Bilski, P ;
Olko, P ;
Budzanowski, M ;
Ochab, E ;
Waligórski, MPR .
RADIATION PROTECTION DOSIMETRY, 1999, 85 (1-4) :367-372
[6]   Efficiency of thermoluminescent detectors to heavy charged particles [J].
Geiss, OB ;
Kramer, M ;
Kraft, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1998, 142 (04) :592-598
[7]   Theory of heavy charged particle response (efficiency and supralinearity) in TL materials [J].
Horowitz, YS ;
Avila, O ;
Rodriguez-Villafuerte, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2001, 184 (1-2) :85-112
[8]  
Olko P, 2002, J RADIAT RES, V43, pS59
[9]  
Uchihori Y, 2002, J RADIAT RES, V43, pS81
[10]   SUPRALINEARITY OF PEAK-5 AND PEAK-6 IN TLD-700 [J].
WALIGORSKI, MPR ;
KATZ, R .
NUCLEAR INSTRUMENTS & METHODS, 1980, 175 (01) :48-50