A Novel Semiautomatic Parenchyma Extraction Method for Improved MRI R2*Relaxometry of Iron Loaded Liver

被引:6
作者
Feng, Yanqiu [1 ]
Feng, Meiyan [1 ]
Gao, Huashuai [1 ]
Zhang, Xinyuan [1 ]
Xin, Xuegang [1 ]
Feng, Qianjin [1 ]
Chen, Wufan [1 ]
He, Taigang [2 ,3 ]
机构
[1] Southern Med Univ, Sch Biomed Engn, Guangzhou, Guangdong, Peoples R China
[2] St Georges Univ London, Cardiovasc Sci Res Ctr, London, England
[3] Royal Brompton Hosp, Cardiovasc Biomed Res Unit, London SW3 6LY, England
基金
英国惠康基金;
关键词
magnetic resonance imaging; R2*; liver iron; semiautomatic parenchyma extraction; HEPATIC IRON; MAGNETIC-RESONANCE; OVERLOAD; THALASSEMIA; DIAGNOSIS; QUANTIFICATION; THERAPY; STORES;
D O I
10.1002/jmri.24331
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To propose and evaluate an automatic method of extracting parenchyma from a manually delineated whole liver for the R2* measurement of iron load. Materials and Methods: In all, 108 transfusion-dependent patients with a wide range of hepatic iron content were scanned with a multiecho gradient-echo sequence. The R2* was measured by fitting the average signal of liver parenchyma, extracted by the proposed semiautomatic parenchyma extraction (SAPE), traditional manually delineated multiple regions-of-interest (mROIs), and T2* thresholding methods to the noise-corrected monoexponential model. The R2* measurement accuracy of the SAPE method was evaluated through simulation; the intra- and interobserver reproducibility of SAPE, mROI, and T2* thresholding were assessed from the in vivo data using coefficient of variation (CoV). Results: In the simulation, the mean absolute percentage error of R2* measurement using SAPE was 0.23% (range 0.01%-1.09%). In vivo study, the CoVs of intra- and interobserver reproducibility were 0.83%, 1.39% for SAPE, 3.63%, 6.28% for mROI, and 1.62%, 2.66% for T2* thresholding, respectively. Conclusion: The SAPE method provides an accurate and reliable approach to assessing the overall hepatic iron content. The improved magnetic resonance imaging (MRI) R2* reproducibility using the SAPE method may lead to more accurate tissue characterization and increased diagnostic confidence.
引用
收藏
页码:67 / 78
页数:12
相关论文
共 50 条
  • [41] Complex confounder-corrected R2* mapping for liver iron quantification with MRI
    Diego Hernando
    Rachel J. Cook
    Naila Qazi
    Colin A. Longhurst
    Carol A. Diamond
    Scott B. Reeder
    European Radiology, 2021, 31 : 264 - 275
  • [42] Performance of different Dixon-based methods for MR liver iron assessment in comparison to a biopsy-validated R2* relaxometry method
    Benjamin Henninger
    Michaela Plaikner
    Heinz Zoller
    André Viveiros
    Stephan Kannengiesser
    Werner Jaschke
    Christian Kremser
    European Radiology, 2021, 31 : 2252 - 2262
  • [43] Real-life experience with liver iron concentration R2 MRI measurement in patients with hemoglobinopathies: baseline data from LICNET
    Vitrano, Angela
    Calvaruso, Giuseppina
    Tese, Lorenzo
    Gioia, Francesco
    Cassara, Filippo
    Campisi, Saveria
    Butera, Franco
    Commendatore, Valeria
    Rizzo, Michele
    Santoro, Vincenzo
    Cigna, Valeria
    Quota, Alessandra
    Bagnato, Sabrina
    Argento, Crocetta
    Fidone, Carmelo
    Schembari, Dario
    Gerardi, Calogera
    Barbiera, Filippo
    Bellisssima, Giuseppe
    Giugno, Giovanni
    Polizzi, Gesualdo
    Rosso, Rosamaria
    Abbate, Giovanna
    Caruso, Vincenzo
    Chiodi, Elisabetta
    Gamberini, Maria Rita
    Giorgi, Benedetta
    Putti, Maria Caterina
    Filosa, Aldo
    De Ritis, Maria Rosaria
    Oliva, Esther
    Arcadi, Nicola
    Fustaneo, Maria
    Mistretta, Laura
    Di Maggio, Rosario
    Sacco, Massimiliano
    Veronica, Di Salvo
    Giangreco, Antonino
    Maggio, Aurelio
    EUROPEAN JOURNAL OF HAEMATOLOGY, 2016, 97 (04) : 361 - 370
  • [44] Prediction of MRI R2* relaxometry in the presence of hepatic steatosis by Monte Carlo simulations
    Ma, Mengyuan
    Cheng, Junying
    Li, Xiaoben
    Fan, Zhuangzhuang
    Wang, Changqing
    Reeder, Scott B.
    Hernando, Diego
    NMR IN BIOMEDICINE, 2025, 38 (01)
  • [45] Evaluation of liver iron overload with R2* relaxometry with versus without fat suppression: both are clinically accurate but there are differences
    M. Plaikner
    C. Kremser
    H. Zoller
    W. Jaschke
    M. Steurer
    A. Viveiros
    B. Henninger
    European Radiology, 2020, 30 : 5826 - 5833
  • [46] Volumetric Evaluation of 3D Multi-Gradient-Echo MRI Data to AssessWhole Liver Iron Distribution by Segmental R2*Analysis:First Experience
    Wunderlich, Arthur P.
    Cario, Holger
    Kannengiesser, Stephan
    Grunau, Veronika
    Hering, Lena
    Goetz, Michael
    Beer, Meinrad
    Schmidt, Stefan Andreas
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2023, 195 (03): : 224 - 233
  • [47] R2* magnetic resonance imaging of the liver in patients with iron overload
    Hankins, Jane S.
    McCarville, M. Beth
    Loeffler, Ralf B.
    Smeltzer, Matthew P.
    Onciu, Mihaela
    Hoffer, Fredric A.
    Li, Chin-Shang
    Wang, Winfred C.
    Ware, Russell E.
    Hillenbrand, Claudia M.
    BLOOD, 2009, 113 (20) : 4853 - 4855
  • [48] Improved R2* liver iron concentration assessment using a novel fuzzy c-mean clustering scheme
    Pairash Saiviroonporn
    Vip Viprakasit
    Rungroj Krittayaphong
    BMC Medical Imaging, 15
  • [49] Measurement of the liver iron concentration in transfusional iron overload by MRI R2*and by high-transition-temperature superconducting magnetic susceptometry
    Sheth, Sujit
    Allen, Christopher J.
    Farrell, David E.
    Tripp, John H.
    Jafari, Ramin
    Wang, Yi
    Brittenham, Gary M.
    CLINICAL IMAGING, 2019, 55 : 65 - 70
  • [50] Quantification of Prenatal Liver and Spleen Iron in a Sheep Model and Assessment of Iron Stores in a Human Neonate with Neonatal Hemochromatosis using R2*Mapping
    Schoennagel, Bjoern P.
    Remus, Chressen C.
    Wedegaertner, Ulrike
    Salzmann, Ina
    Grabhorn, Enke
    Adam, Gerhard
    Fischer, Roland
    Harmatz, Paul
    Kooijman, Hendrik
    Yamamura, Jin
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2014, 13 (03) : 167 - 173