A Novel Semiautomatic Parenchyma Extraction Method for Improved MRI R2*Relaxometry of Iron Loaded Liver

被引:6
|
作者
Feng, Yanqiu [1 ]
Feng, Meiyan [1 ]
Gao, Huashuai [1 ]
Zhang, Xinyuan [1 ]
Xin, Xuegang [1 ]
Feng, Qianjin [1 ]
Chen, Wufan [1 ]
He, Taigang [2 ,3 ]
机构
[1] Southern Med Univ, Sch Biomed Engn, Guangzhou, Guangdong, Peoples R China
[2] St Georges Univ London, Cardiovasc Sci Res Ctr, London, England
[3] Royal Brompton Hosp, Cardiovasc Biomed Res Unit, London SW3 6LY, England
基金
英国惠康基金;
关键词
magnetic resonance imaging; R2*; liver iron; semiautomatic parenchyma extraction; HEPATIC IRON; MAGNETIC-RESONANCE; OVERLOAD; THALASSEMIA; DIAGNOSIS; QUANTIFICATION; THERAPY; STORES;
D O I
10.1002/jmri.24331
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To propose and evaluate an automatic method of extracting parenchyma from a manually delineated whole liver for the R2* measurement of iron load. Materials and Methods: In all, 108 transfusion-dependent patients with a wide range of hepatic iron content were scanned with a multiecho gradient-echo sequence. The R2* was measured by fitting the average signal of liver parenchyma, extracted by the proposed semiautomatic parenchyma extraction (SAPE), traditional manually delineated multiple regions-of-interest (mROIs), and T2* thresholding methods to the noise-corrected monoexponential model. The R2* measurement accuracy of the SAPE method was evaluated through simulation; the intra- and interobserver reproducibility of SAPE, mROI, and T2* thresholding were assessed from the in vivo data using coefficient of variation (CoV). Results: In the simulation, the mean absolute percentage error of R2* measurement using SAPE was 0.23% (range 0.01%-1.09%). In vivo study, the CoVs of intra- and interobserver reproducibility were 0.83%, 1.39% for SAPE, 3.63%, 6.28% for mROI, and 1.62%, 2.66% for T2* thresholding, respectively. Conclusion: The SAPE method provides an accurate and reliable approach to assessing the overall hepatic iron content. The improved magnetic resonance imaging (MRI) R2* reproducibility using the SAPE method may lead to more accurate tissue characterization and increased diagnostic confidence.
引用
收藏
页码:67 / 78
页数:12
相关论文
共 50 条
  • [1] A fully automatic parenchyma extraction method for MRI T2*relaxometry of iron loaded liver in transfusion-dependent patients
    Lian, Zifeng
    Lu, Qiqi
    Lin, Bingquan
    Chen, Lingjian
    Gong, Jian
    Hu, Qiugen
    Wang, Huafeng
    Feng, Yanqiu
    MAGNETIC RESONANCE IMAGING, 2024, 109 : 18 - 26
  • [2] Improved MRI R2* Relaxometry of Iron-Loaded Liver with Noise Correction
    Feng, Yanqiu
    He, Taigang
    Gatehouse, Peter D.
    Li, Xinzhong
    Harith Alam, Mohammed
    Pennell, Dudley J.
    Chen, Wufan
    Firmin, David N.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (06) : 1765 - 1774
  • [3] Complex confounder-corrected R2*mapping for liver iron quantification with MRI
    Hernando, Diego
    Cook, Rachel J.
    Qazi, Naila
    Longhurst, Colin A.
    Diamond, Carol A.
    Reeder, Scott B.
    EUROPEAN RADIOLOGY, 2021, 31 (01) : 264 - 275
  • [4] Evaluation of liver iron overload with R2*relaxometry with versus without fat suppression: both are clinically accurate but there are differences
    Plaikner, M.
    Kremser, C.
    Zoller, H.
    Jaschke, W.
    Steurer, M.
    Viveiros, A.
    Henninger, B.
    EUROPEAN RADIOLOGY, 2020, 30 (11) : 5826 - 5833
  • [5] A semiautomatic postprocessing of liver R2* measurement for assessment of liver iron overload
    Deng, Jie
    Rigsby, Cynthia K.
    Schoeneman, Samantha
    Boylan, Emma
    MAGNETIC RESONANCE IMAGING, 2012, 30 (06) : 799 - 806
  • [6] R2 relaxometry based MR imaging for estimation of liver iron content: A comparison between two methods
    Calle-Toro, Juan S.
    Barrera, Christian A.
    Khrichenko, Dmitry
    Otero, Hansel J.
    Serai, Suraj D.
    ABDOMINAL RADIOLOGY, 2019, 44 (09) : 3058 - 3068
  • [7] Liver iron overload assessment by MRI R2*relaxometry in highly transfused pediatric patients: An agreement and reproducibility study
    Verlhac, S.
    Morel, M.
    Bernaudin, F.
    Bechet, S.
    Jung, C.
    Vasile, M.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2015, 96 (03) : 259 - 264
  • [8] Accuracy of MRI R2*Mapping in Diagnosis of Liver Iron Concentration: A Meta-Analysis
    Cao, Sue
    Gao, Xin
    Wang, Hua
    Chen, Yaoping
    Xu, Jianbo
    Zhang, Jie
    Guo, Ruomi
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2025,
  • [9] Reproducibility of liver iron concentration measured by R2*method based on 1.5-T MRI: a meta-analysis
    Cao, Sue
    Zhang, Jie
    Dong, Chenyu
    Que, Yutao
    Gao, Xin
    Guo, Ruomi
    EUROPEAN RADIOLOGY, 2025,
  • [10] Biexponential R2*relaxometry for estimation of liver iron concentration in children: A better fit for high liver iron states
    Barrera, Christian A.
    Khrichenko, Dmitry
    Serai, Suraj D.
    Hartung, Helge D.
    Biko, David M.
    Otero, Hansel J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 50 (04) : 1191 - 1198