Corrections of fast neutron inelastic scattering effects on D-T neutron porosity logging

被引:8
作者
Yu, Huawei [1 ,2 ]
Wang, Zhe [2 ]
Xue, Zhibo [3 ]
Shang, Xiusheng [3 ]
Zhang, Qianwen [2 ]
Zhang, Li [4 ]
Li, Shiding [2 ]
机构
[1] China Univ Petr East China, Key Lab Deep Oil & Gas, Qingdao 266580, Peoples R China
[2] China Univ Petr East China, Sch Geosci, Qingdao 266580, Peoples R China
[3] China Oilfield Serv Ltd, Well Tech Dept, Yanjiao 065201, Peoples R China
[4] Shandong Univ Sci & Technol, Dept Resources & Civil Engn, Tai An 271019, Peoples R China
基金
中国国家自然科学基金;
关键词
D -T neutron source; Am -Be neutron Source; Neutron porosity; Inelastic scattering; Slowing -down length;
D O I
10.1016/j.apradiso.2022.110486
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
With the continuous development of logging tools with controllable neutron sources, improving the processing method to make their measurements more consistent with those obtained by chemical sources has become a development trend in well logging based on controllable sources. To study the correction method that is not constrained by other parameters and does not require chemical sources, the reasons for the differences in the neutron porosity responses of D-T and chemical sources are theoretically analyzed. Then the fast neutron slowing-down process is divided into two stages depending on neutron energy. A method to correct the effects of inelastic scattering in D-T neutron porosity is established through the derivation of the theoretical relationship. Finally, the effectiveness of the correction method is verified using the simulation and measured data. The results show that after inelastic scattering correction, the measurement results of neutron porosity logging with controllable and chemical sources are highly consistent, and there is a close correspondence between the two types of sources in terms of measured data. Therefore, the proposed inelastic scattering correction method can effectively replace density correction to make the measurement results of the D-T neutron source more consistent with those of chemical sources. This study is of great significance for the wide application of neutron porosity measurement with controllable neutron sources and the replacement of radioactive sources in logging tools in the future.
引用
收藏
页数:7
相关论文
共 16 条
  • [1] Briesmeister J.F., 1986, MCNP GEN M CARLO COD
  • [2] Electronic neutron sources for compensated porosity well logging
    Chen, A. X.
    Antolak, A. J.
    Leung, K. -N.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 684 : 52 - 56
  • [3] Ellis D.V., 2008, WELL LOGGING EARTH S
  • [4] Fricke S., 2008, SPWLA 49 ANN LOGG S
  • [5] Huang L., 2000, NUCL LOGGING PRINCIP, P102
  • [6] A method to improve the sensitivity of neutron porosity measurement based on D-T source
    Liu, Juntao
    Zhang, Feng
    Gardner, Robin P.
    Hou, Guojing
    Zhang, Quanying
    Zhang, Yan
    Li, Xianghui
    Li, Hu
    Hu, Cong
    [J]. JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2016, 33 : 879 - 884
  • [7] SNUPAR - A NUCLEAR PARAMETER CODE FOR NUCLEAR GEOPHYSICS APPLICATIONS
    MCKEON, DC
    SCOTT, HD
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) : 1215 - 1219
  • [8] Wang H., 2021, WELL LOGGING TECHNOL, V45, P552
  • [9] [王虎 Wang Hu], 2018, [核技术, Nuclear Techniques], V41, P080406
  • [10] Weller G., 2005, SPWLA 46 ANN LOGG S