Flexible operation of a combined cycle cogeneration plant - A techno-economic assessment

被引:27
作者
Beiron, Johanna [1 ]
Montanes, Ruben M. [1 ]
Normann, Fredrik [1 ]
Johnsson, Filip [1 ]
机构
[1] Chalmers Univ Technol, Dept Space Earth & Environm, Gothenburg, Sweden
关键词
Gas turbine combined cycle; Combined heat and power; District heating; Flexibility; Steam cycle; Process optimization; FIRED POWER-PLANTS; CONTROL STRATEGIES; FLEXIBILITY; IMPACT; GAS; SYSTEM; FUTURE; MODEL; HEAT; PERFORMANCE;
D O I
10.1016/j.apenergy.2020.115630
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The need for flexibility in combined heat and power (CHP) plants is expected to increase due to the strong expansion of wind power in electricity systems. Cost-effective strategies to enhance the flexibility of CHP operation are therefore needed. This paper analyzes three types of flexibility measures for a combined cycle CHP plant and their relative impact on the plant operation and revenue. The types of flexibility are: operational flexibility of the fuel conversion system, product flexibility with variable plant product ratios (heat/electricity/ primary frequency response), and thermal flexibility in a district heating network. A modeling framework consisting of steady-state and dynamic process simulation models and optimization model is developed to combine static, dynamic, technical and economic perspectives on flexibility. A reference plant serves as a basis for the process model development and validation, and an energy system model provides input profiles for future electricity price scenarios. The results indicate that product flexibility and thermal flexibility have the highest value for the cogeneration plant (up to 16.5 MEuro increased revenue for a 250 MWel plant), while operational flexibility (ramp rate) has a comparatively small impact (<1.4 MEuro). A wide load span and plant versatility, e.g. electricity and heat generating potential between 0 and 139% of nominal capacity, is beneficial in future energy system contexts, but has a marginal value in the current system. Electricity price volatility is a main driver that increases the value of flexibility and promotes operating strategies that follow the electricity price profile rather than the heat demand.
引用
收藏
页数:18
相关论文
共 51 条
[1]   Transient simulation and fatigue evaluation of fast gas turbine startups and shutdowns in a combined cycle plant with an innovative thermal buffer storage [J].
Angerer, Michael ;
Kahlert, Steffen ;
Spliethoff, Hartmut .
ENERGY, 2017, 130 :246-257
[2]  
[Anonymous], 2009, ECOS 2009
[3]  
[Anonymous], 2020, DYMOLA SYSTEMS ENG
[4]  
[Anonymous], 2020, EBSILON PROFESSIONAL
[5]   Combined heat and power operational modes for increased product flexibility in a waste incineration plant [J].
Beiron, Johanna ;
Montanes, Ruben M. ;
Normann, Fredrik ;
Johnsson, Filip .
ENERGY, 2020, 202
[6]   Dynamic modeling for assessment of steam cycle operation in waste-fired combined heat and power plants [J].
Beiron, Johanna ;
Montanes, Ruben M. ;
Normann, Fredrik ;
Johnsson, Filip .
ENERGY CONVERSION AND MANAGEMENT, 2019, 198
[7]   Superheater and Drum Lifetime Estimation: An Approach Based on Dynamic Analysis [J].
Benato, Alberto ;
Stoppato, Anna ;
Mirandola, Alberto ;
Destro, Nicola ;
Bracco, Stefano .
JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2017, 139 (03)
[8]   Dynamic behaviour analysis of a three pressure level heat recovery steam generator during transient operation [J].
Benato, Alberto ;
Stoppato, Anna ;
Mirandola, Alberto .
ENERGY, 2015, 90 :1595-1605
[9]   Operational flexibility and economics of power plants in future low-carbon power systems [J].
Brouwer, Anne Sjoerd ;
van den Broek, Machteld ;
Seebregts, Ad ;
Faaij, Andre .
APPLIED ENERGY, 2015, 156 :107-128
[10]  
Cáceres IE, 2018, J POWER TECHNOL, V98, P188