Measurement of glutathione in human brain at 3T using an improved double quantum filter in vivo

被引:14
作者
Choi, Changho [1 ]
Zhao, Chenguang [1 ]
Dimitrov, Ivan [1 ,2 ]
Douglas, Deborah [1 ]
Coupland, Nicholas J. [3 ]
Kalra, Sanjay [3 ]
Hawesa, Halima [1 ]
Davis, Jeannie [1 ]
机构
[1] Univ Texas SW Med Ctr Dallas, Adv Imaging Res Ctr, Dallas, TX 75390 USA
[2] Philips Med Syst, Cleveland, OH USA
[3] Univ Alberta, Edmonton, AB, Canada
关键词
Double quantum filtering; Dual DQC encoding; Glutathione; Human brain; NMR-SPECTROSCOPY; H-1; MRS; COHERENCE; GLUTAMATE; TESLA; METABOLITES; SPECTRA; TIMES;
D O I
10.1016/j.jmr.2009.02.002
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A single voxel proton NMR double quantum filter (DQF) for measurement of glutathione (GSH) in human brain at 3T is reported. Yield enhancement for the CH(2) resonances of the cysteine moiety at 2.95 ppm has been achieved by means of dual encoding. After the preparation of double quantum and zero quantum coherences (DQC and ZQC) at equal magnitude, the first DQC encoding was followed by interchange of DQC and ZQC, and another DQC encoding. The multi-quantum coherences were fully utilized to generate a GSH target signal at similar to 2.95 ppm. The optimal echo time and the editing efficiency were obtained with numerical analysis of the filtering performance and phantom measurements. The dual-DQC encoding method provided GSH yield greater by a factor of 2.1 than single-DQC encoding for identical slice-selective RF pulses in phantom tests. Using the phantom relaxation times and the ratio of edited GSH to N-acetylaspartate (NAA) 2.0-ppm peak areas, the concentration of GSH in the medial parietal cortex of the healthy human brain in vivo was estimated to be 1.0 +/- 0.3 mM (mean +/- SD, n = 7), with reference to NAA at 10 mM. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:160 / 166
页数:7
相关论文
共 34 条
  • [1] Allen PS, 1997, NMR BIOMED, V10, P435, DOI 10.1002/(SICI)1099-1492(199712)10:8<435::AID-NBM480>3.0.CO
  • [2] 2-D
  • [3] [Anonymous], 1990, Principles of Nuclear Magnetic Resonance in One and Two Dimensions
  • [5] Measurement of brain glutamate and glutamine by spectrally-selective refocusing at 3 tesla
    Choi, C
    Coupland, NJ
    Bhardwaj, PP
    Malykhin, N
    Gheorghiu, D
    Allen, PS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (05) : 997 - 1005
  • [6] Measurement of glycine in human brain by triple refocusing 1H-MRS in vivo at 3.0T
    Choi, Changho
    Bhardwaj, Paramjit P.
    Seres, Peter
    Kalra, Sanjay
    Tibbo, Philip G.
    Coupland, Nicholas J.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (01) : 59 - 64
  • [7] T2 measurement and quantification of glutamate in human brain in vivo
    Choi, Changho
    Coupland, Nicholas J.
    Bhardwaj, Paramjit P.
    Kalra, Sanjay
    Casault, Colin A.
    Reid, Kim
    Allen, Peter S.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (05) : 971 - 977
  • [8] Single-shot two-echo technique for simultaneous measurement of GABA and creatine in the human brain in vivo
    Choi, IY
    Lee, SP
    Merkle, H
    Shen, J
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (06) : 1115 - 1121
  • [9] CHOI IY, 2004, P 12 ANN M ISMRM KYO, P683
  • [10] Schizophrenia:: glutathione deficit in cerebrospinal fluid and prefrontal cortex in vivo
    Do, KQ
    Trabesinger, AH
    Kirsten-Krüger, M
    Lauer, CJ
    Dydak, U
    Hell, D
    Holsboer, F
    Boesiger, P
    Cuénod, M
    [J]. EUROPEAN JOURNAL OF NEUROSCIENCE, 2000, 12 (10) : 3721 - 3728