Determination of nitrofurantoin drug in pharmaceutical formulation and biological fluids by square-wave cathodic adsorptive stripping voltammetry

被引:43
作者
Hammam, E [1 ]
机构
[1] Tanta Univ, Fac Sci, Dept Chem, Tanta 31527, Egypt
关键词
nitrofurantoin determination; square-wave cathodic adsorptive stripping voltammetry; assay of pharmaceutical formulation; human serum and urine;
D O I
10.1016/S0731-7085(02)00344-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Nitrofurnation is an antibacterial drug. It is used in the treatment of initial or recurrent urinary tract infections caused by susceptible organisms. The cyclic voltammogram of the drug in Britton-Robinson buffers (pH 2-11) exhibited a single well-defined cathodic peak at the hanging mercury drop electrode, that due to the reduction of its nitro group to the amine stage. A fully validated, sensitive, and reproducible developed procedure was described for determination of the drug in bulk form, pharmaceutical formulation, human serum and human urine using, square-wave cathodic adsorptive stripping voltammetry. The optimal experimental parameters for the drug assay were: accumulation potential = -0.4 V (vs. Ag/AgCl/KCls), accumulation time = 40 s, frequency = 120 Hz, pulse amplitude = 50 mV and scan increment = 10 mV in Britton-Robinson buffer (pH 10). A mean percentage recovery of 100.68 +/- 0.17 (n = 5) and a detection limit of 1.32 x 10(-10) M of bulk drug were achieved. Applicability to assay of the drug in pharmaceutical formulation, human serum and human urine was studied and illustrated. The mean percentage recoveries were found as: 101.49 +/- 0.65, 103.94 +/- 0.73 and 101.98 +/- 0.52 (n = 5) in pharmaceutical formulation, human serum and human urine, respectively. Detection limits of 2.86 x 10(-10) M and 5.77 x 10(-10) M nitrofurantoin were achieved in human serum and urine, respectively. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:651 / 659
页数:9
相关论文
共 37 条
[11]  
Faith L, 1983, Cesk Farm, V32, P19
[12]   REDUCTIVE AMPEROMETRIC DETERMINATION OF NITROFURANTOIN AND ACETAZOLAMIDE AT A SESSILE MERCURY DROP ELECTRODE USING FLOW-INJECTION ANALYSIS [J].
FOGG, AG ;
GHAWJI, AB .
ANALYST, 1988, 113 (05) :727-730
[14]   Determination of Norfloxacin by square-wave adsorptive voltammetry on a glassy carbon electrode [J].
Ghoneim, MM ;
Radi, A ;
Beltagi, AM .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 25 (02) :205-210
[15]   Determination of trimetazidine HCl by adsorptive stripping square-wave voltammetry at a glassy carbon electrode [J].
Ghoneim, MM ;
Khashaba, PY ;
Beltagi, AM .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 27 (1-2) :235-241
[16]  
HASSAN SM, 1988, ANAL LETT, V21, P1199
[17]   APPLICATION OF DIFFERENCE SPECTROSCOPY TO THE DETERMINATION OF SOME PHARMACEUTICALLY IMPORTANT NITRO-COMPOUNDS [J].
HASSAN, SM ;
ELDIN, MS ;
BELAL, F ;
SULTAN, M .
JOURNAL OF PHARMACY AND PHARMACOLOGY, 1988, 40 (11) :798-800
[18]  
Khodari M, 1998, ANAL LETT, V31, P251
[19]  
LAVIRON E, 1980, J ELECTROANAL CHEM, V112, P1, DOI 10.1016/S0022-0728(80)80002-7
[20]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF NITROFURANTOIN IN PLASMA [J].
MANDAL, TK ;
ACE, LN .
JOURNAL OF CLINICAL PHARMACY AND THERAPEUTICS, 1993, 18 (05) :347-350