Replacement of the Distorted Dentition of the Cone-Beam Computed Tomography Scans for Orthognathic Surgery Planning

被引:15
|
作者
Almutairi, Turki [1 ]
Naudi, Kurt [2 ]
Nairn, Neil [1 ]
Ju, Xiangyang [3 ]
Whitters, John [1 ]
Ayoub, Ashraf [4 ]
机构
[1] Univ Glasgow, Dent Sch, Sch Med Dent & Nursing, MVLS Coll, Glasgow, Lanark, Scotland
[2] Univ Glasgow, Dent Sch, Sch Med Dent & Nursing, MVLS Coll,Oral Surg, Glasgow, Lanark, Scotland
[3] Univ Glasgow, Dent Sch, Sch Med Dent & Nursing, MVLS Coll,Med Device Unit, Glasgow, Lanark, Scotland
[4] Univ Glasgow, Dent Sch, Sch Med Dent & Nursing, MVLS Coll,Oral & Maxillofacial Surg, Glasgow, Lanark, Scotland
关键词
FUSION; CT; SUPERIMPOSITION; REGISTRATION; ARTIFACT; MODELS;
D O I
10.1016/j.joms.2018.02.018
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Cone-beam computed tomography (CBCT) does not record dental morphology accurately because of the scattering produced by metallic restorations and the reported magnification of the dentition. The aim of this study was the development and evaluation of a new method for the replacement of the distorted dentition of CBCT scans with a 3-dimensional (3D) dental image captured by a digital intraoral camera. Materials and Methods: Six dried skulls with orthodontic brackets fixed on the teeth were used in this study. Three intraoral markers made of dental stone were constructed and attached to orthodontic brackets. The skulls were scanned by CBCT and the occlusal surfaces were captured using the TRIOS 3D intraoral scanner. The digital intraoral scan (IOS) was fused into the CBCT models. This produced a new composite digital model of the skull and the dentition. The skulls were scanned again using the commercially accurate Faro laser arm to produce the 3D model the skull and teeth gold standard for the assessment of the accuracy of the developed method. This was assessed by measuring the distance between the occlusal surfaces of the new composite model and the gold standard 3D laser produced model. Results: The results showed the errors related to the superimposition of the intraoral image on the CBCT to replace the distorted dentition were 0.11 to 0.20 mm. Conclusion: The results of this novel method suggest that the dentition on the CBCT scan can be accurately replaced with the digital IOS image captured by an intraoral scanner to create a composite model that will improve the accuracy of digital orthognathic surgical planning and the fabrication of the guiding occlusal wafer. (C) 2018 Published by Elsevier Inc. on behalf of the American Association of Oral and Maxillofacial Surgeons
引用
收藏
页码:1561.e1 / 1561.e8
页数:8
相关论文
共 50 条
  • [1] Digital replacement of the distorted dentition acquired by cone beam computed tomography (CBCT): a pilot study
    Nairn, N. J.
    Ayoub, A. F.
    Barbenel, J.
    Moos, K.
    Naudi, K.
    Ju, X.
    Khambay, B. S.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2013, 42 (11) : 1488 - 1493
  • [2] A novel method for fusion of intra-oral scans and cone-beam computed tomography scans for orthognathic surgery planning
    de Waard, Olivier
    Baan, Frank
    Verhamme, Luc
    Breuning, Hero
    Kuijpers-Jagtman, Anne Marie
    Maal, Thomas
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2016, 44 (02) : 160 - 166
  • [3] Evaluating the mandible with cone-beam computed tomography
    Stratemann, Scott A.
    Huang, John C.
    Maki, Koutaro
    Hatcher, David C.
    Miller, Arthur J.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (04) : S58 - S70
  • [4] Comparison of Pharyngeal Airway Changes on Plain Radiography and Cone-Beam Computed Tomography After Orthognathic Surgery
    Sears, Chad R.
    Miller, Arthur J.
    Chang, Michael K.
    Huang, John C.
    Lee, Janice S.
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2011, 69 (11) : E385 - E394
  • [5] Accuracy of reconstructed images from cone-beam computed tomography scans
    Lamichane, Manish
    Anderson, Nina Kay
    Rigali, Paul H.
    Seldin, Edward B.
    Will, Leslie A.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (02) : 156.e1 - 156.e6
  • [6] Palatal volume and area assessment on digital casts generated from cone-beam computed tomography scans
    Shahen, Shereef
    Carrino, Gennaro
    Carrino, Rossella
    Abdelsalam, Reham
    Flores-Mir, Carlos
    Perillo, Letizia
    ANGLE ORTHODONTIST, 2018, 88 (04) : 397 - 402
  • [7] The role of cone-beam computed tomography in the planning and placement of implants
    Worthington, Philip
    Rubenstein, Jeffrey
    Hatcher, David C.
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2010, 141 (10) : 19S - 24S
  • [8] Cone-Beam Computed Tomography in Periodontal Diagnosis and Treatment Planning
    Murali, Aparna C.
    Bhandary, Rahul
    JOURNAL OF HEALTH AND ALLIED SCIENCES NU, 2022,
  • [9] Cone-beam computed tomography for trauma
    Gupta, Saurabh
    Martinson, James R.
    Ricaurte, Daniel
    Scalea, Thomas M.
    Morrison, Jonathan J.
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2020, 89 (03) : E34 - E40
  • [10] Correlation of Airway Volume With Orthognathic Surgical Movement Using Cone-Beam Computed Tomography
    Chang, Michael K.
    Sears, Chad
    Huang, John C.
    Miller, Arthur J.
    Kushner, Harvey W.
    Lee, Janice S.
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2015, 73 (12) : S67 - S76