Development of improved superconductive axial gradiometers for biomagnetic SQUID applications

被引:2
|
作者
Budnyk, M. M. [1 ]
Minov, Yu. D. [1 ]
Lyakhno, V. Yu. [2 ]
Desnenko, V. A. [2 ]
Linnik, A. S. [2 ]
Shopen, O. B. [3 ]
机构
[1] Natl Acad Sci Ukraine, VM Glushkov Inst Cybernet, 40 Glushkov Ave, UA-03187 Kiev, Ukraine
[2] Natl Acad Sci Ukraine, BI Verkin Inst Low Temp Phys & Engn, 47 Nauki Ave, UA-61103 Kharkov, Ukraine
[3] Res & Prod Enterprise Plastar Ltd, 8 Razin Str, UA-62203 Kharkov, Ukraine
关键词
D O I
10.1063/1.5024543
中图分类号
O59 [应用物理学];
学科分类号
摘要
SQUID magnetometers for biomagnetic measurements are equipped with superconductive gradiometers which are required to provide a high signal-to-noise ratio at low frequencies, sufficient mechanical strength and sustained performance under repeated thermal cycles, as well as a low level of intrinsic magnetic noise. This paper describes the design of a gradiometer made with a carbon-fiber reinforced composite material for magnetic cardiography measurements. The thermal coefficient of linear expansion (TCLE) of the carbon fiber composite can be precisely adjusted to match that of the superconducting detector coil wire. This is achieved thanks to the difference in the TCLE of carbon fibers in the longitudinal and transverse directions and is realized by varying the laying directions of the fiber in the composite. The data of magnetic susceptibility measurements on carbon fiber composite are reported, showing the magnetic susceptibility about six times smaller than that of graphite. The presented gradiometer design provides a high degree of balancing and is patented along side other specific techniques. Published by AIP Publishing.
引用
收藏
页码:233 / 237
页数:5
相关论文
共 50 条
  • [1] Development of improved superconductive axial gradiometers for SQUID biomagnetic application
    Budnyk, M.M.
    Minov, Yu.D.
    Lyakhno, V.Yu.
    Desnenko, V.A.
    Linnik, A.S.
    Shopen, O.B.
    Fizika Nizkikh Temperatur, 2018, 44 (03): : 308 - 313
  • [2] Three dimensionally configured SQUID vector gradiometers for biomagnetic measurement
    Adachi, Y
    Kawai, J
    Miyamoto, M
    Uehara, G
    Kawabata, S
    Okubo, H
    Fukuoka, Y
    Komori, H
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2003, 16 (12): : 1442 - 1446
  • [3] SQUID AND SQUID SYSTEM DEVELOPMENTS FOR BIOMAGNETIC APPLICATIONS
    HEIDEN, C
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1991, 12 : 67 - 73
  • [4] Development of planar thin film HTSC-SQUID gradiometers for different applications
    Dörrer, L
    Wunderlich, S
    Schmidl, F
    Schneidewind, H
    Hübner, U
    Seidel, P
    APPLIED SUPERCONDUCTIVITY, 1998, 6 (7-9) : 349 - 354
  • [5] Flux/voltage calibration of axial SQUID gradiometers using an optimization procedure
    Barbosa, CH
    Lima, EA
    Bruno, AC
    Ewing, AP
    Wikswo, JP
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1999, 9 (02) : 3523 - 3526
  • [7] Sensitive HTS DC-SQUID gradiometers for magnetic evaluation applications
    Faley, MI
    Poppe, U
    Urban, K
    Paulson, DN
    Starr, TN
    Fagaly, RL
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2002, 372 : 217 - 220
  • [8] MULTI CHANNEL DC SQUID SENSOR ARRAY FOR BIOMAGNETIC APPLICATIONS
    HOENIG, HE
    DAALMANS, GM
    BAR, L
    BOMMEL, F
    PAULUS, A
    UHL, D
    WEISSE, HJ
    SCHNEIDER, S
    SEIFERT, H
    REICHENBERGER, H
    ABRAHAMFUCHS, K
    IEEE TRANSACTIONS ON MAGNETICS, 1991, 27 (02) : 2777 - 2785
  • [9] THE PTB 83-SQUID SYSTEM FOR BIOMAGNETIC APPLICATIONS IN A CLINIC
    DRUNG, D
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1995, 5 (02) : 2112 - 2117
  • [10] DESIGN OF IMPROVED INTEGRATED THIN-FILM PLANAR DC SQUID GRADIOMETERS
    KETCHEN, MB
    JOURNAL OF APPLIED PHYSICS, 1985, 58 (11) : 4322 - 4325