Detection and measurement of power quality disturbances using wavelet transform

被引:0
|
作者
Poisson, O [1 ]
Rioual, P [1 ]
Meunier, M [1 ]
机构
[1] EDF, Direct Etud & Rech, Grp Qualite Fourniture & Serv Entreprises, Clamart, France
来源
8TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER, PROCEEDINGS, VOLS 1 AND 2 | 1998年
关键词
continuous wavelet transform; voltage sags; transients;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper deals with the use of a continuous wavelet transform to detect and analyze voltage sags and transients. A recursive algorithm is used and improved to compute the time-frequency plane of these electrical disturbances. Characteristics of investigated signals are measured on a time-frequency plane. A comparison between measured characteristics and benchmark values detects the presence of disturbances in analyzed signals and characterizes the type of disturbances. Duration and magnitude of voltage sags are measured, transients are located in the width of the signal. Furthermore, meaningful time and frequency components of transients are measured. The whole method is implemented and tested over a sample representing recorded disturbances. Detection and measurement results are compared using classical methods.