Effect of different high-palladium metal-ceramic alloys on the color of opaque and dentin porcelain

被引:33
作者
Stavridakis, MM
Papazoglou, E
Seghi, RR
Johnston, WM
Brantley, WA
机构
[1] Univ Athens, Sch Dent, Dept Operat Dent, Athens, Greece
[2] Ohio State Univ, Coll Dent, Sect Restorat & Prosthet Dent, Adv Prosthodont Program, Columbus, OH 43210 USA
关键词
D O I
10.1016/j.prosdent.2004.05.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The color of dental porcelain depends on the type of metal substrate. Little research has been done to document the effects of different types of high-palladium alloys on the color of dental porcelain. Purpose. The purpose of this in vitro study was to evaluate the effects of different high-palladium alloys on the resulting color of dentin porcelain, as well as on that of opaque porcelain after simulated dentin and glazing firing cycles. Material and methods. Three Pd-Cu-Ga alloys, Spartan Plus (S), Liberty (13), and Freedom Plus (F), and 5 Pd-Ga alloys, Legacy (L), IS 85 (1), Protocol (P), Legacy XT (X), and Jelenko No. 1 (N), were examined. A Pd-Ag alloy, Super Star (T), was included for comparison to the high-palladium alloys, and the Au-Pd alloy, Olympia (0), served as the control. Six cast discs (16 X I mm) were prepared from each of the alloys. Shade B I opaque porcelain (Vita-Omega) was applied at a final thickness of 0.1 mm. After 2 opaque porcelain firing cycles, the surfaces were airborne-particle abraded, and the specimens were divided into 2 groups. In the first group, 0.9 mm of B1 dentin porcelain was applied. The other group of specimens with only opaque porcelain underwent the same dentin porcelain and glazing firing cycles. Color differences (DeltaE) were determined with a colorimeter between the control and each experimental group, after the second opaque porcelain, second dentin porcelain, and glazing firing cycles. One-way analysis of variance and Dunnett's multiple range test were performed on the DeltaE data (alpha=.05). Results. After the application of dentin porcelain, the 3 Pd-Cu-Ga alloys showed significantly different (P<.05) Delta E values (S = 2.3 +/- 0.5, B = 1.4 +/- 0.3, and F = 1.3 +/- 0.7) than the control group. After the glazing cycle of this group, the 3 Pd-Cu-Ga alloys and the Pd-Ag alloy exhibited significantly different (P<.05) DeltaE values (S = 2.8 +/- 0.8, B = 2.2 +/- 0.3, F = 1.9 +/- 1.0, and T = 1.4 0.5) than the control group. After the simulated dentin porcelain firing cycles, the specimens with only opaque porcelain exhibited significantly different (P<.05) Delta E values (S = 5.2 +/- 1.4, B = 5.4 +/- 0.6, and F = 3.9 +/- 0.2) than the control group. The color difference between the 3 Pd-Cu-Ga alloys with only opaque porcelain and the control group increased more after the simulated glazing cycle (S = 6.6 +/- 1.5, B = 6.3 +/- 0.5, and F = 4.6 +/- 0.1). The observed color differences between the Pd-Ga alloys and the control group were not statistically significant at any point. Conclusions. The Pd-Cu-Ga alloys with only opaque porcelain, after the simulated dentin porcelain and glazing firing cycles, exhibited clinically unacceptable color differences. The application of dentin porcelain to the Pd-Cu-Ga alloys resulted in clinically acceptable color differences. The application of dentin porcelain to the Pd-Ag alloy, after the glazing firing cycle, resulted in clinically acceptable color differences (approximately 2.8 to 3.7 Delta E CIELAB units). The Pd-Ag alloy specimens with only opaque porcelain did not exhibit significant color differences from the control group, whereas significant color differences from the control group after the dentin porcelain and glazing firing cycles were still clinically acceptable.
引用
收藏
页码:170 / 178
页数:9
相关论文
共 34 条
[1]  
[Anonymous], BILLMEYER SALTZMANS
[2]   OPTIMUM THICKNESSES OF OPAQUE AND BODY PORCELAIN [J].
BARGHI, N ;
LORENZANA, RE .
JOURNAL OF PROSTHETIC DENTISTRY, 1982, 48 (04) :429-431
[3]   PORCELAIN SHADE STABILITY AFTER REPEATED FIRING [J].
BARGHI, N ;
GOLDBERG, J .
JOURNAL OF PROSTHETIC DENTISTRY, 1977, 37 (02) :173-175
[4]  
BELL AM, 1985, DENT CLIN N AM, V29, P763
[5]   X-ray diffraction studies of oxidized high-palladium alloys [J].
Brantley, WA ;
Cai, Z ;
Papazoglou, E ;
Mitchell, JC ;
Kerber, SJ ;
Mann, GP ;
Barr, TL .
DENTAL MATERIALS, 1996, 12 (5-6) :333-341
[6]   SPECTROPHOTOMETRIC ANALYSIS OF A NONGREENING, METAL-FUSING PORCELAIN [J].
BREWER, JD ;
GLENNON, JS ;
GARLAPO, DA .
JOURNAL OF PROSTHETIC DENTISTRY, 1991, 65 (05) :634-641
[7]   SPECTROMETRIC ANALYSIS OF THE INFLUENCE OF METAL SUBSTRATES ON THE COLOR OF METAL-CERAMIC RESTORATIONS [J].
BREWER, JD ;
AKERS, CK ;
GARLAPO, DA ;
SORENSEN, SE .
JOURNAL OF DENTAL RESEARCH, 1985, 64 (01) :74-77
[8]  
Carr A B, 1993, Int J Prosthodont, V6, P233
[9]  
Carr A B, 1991, Int J Prosthodont, V4, P265
[10]  
CIE, 1978, CIE PUBL, V15