Dry Eye Disease Association with Computer Exposure Time Among Subjects with Computer Vision Syndrome

被引:42
作者
del Rosario Sanchez-Valerio, Maria [1 ]
Mohamed-Noriega, Karim [2 ]
Zamora-Ginez, Irma [1 ]
Guadalupe Baez Duarte, Blanca [1 ]
Vallejo-Ruiz, Veronica [3 ]
机构
[1] Autonomous Univ Puebla, Fac Med, Puebla, Puebla, Mexico
[2] Autonomous Univ Nuevo Leon UANL, Univ Hosp Jose E Gonzalez, Ophthalmol Dept, Fac Med, Monterrey, Mexico
[3] Metepec, Mexican Social Secur Inst IMSS, Eastern Biomed Res Ctr, Puebla, Mexico
关键词
computer vision syndrome; dry eye disease; RELIABILITY; PREVALENCE; CORNEAL;
D O I
10.2147/OPTH.S252889
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the time of exposure to the computer and dry eye disease (DED) in subjects with computer vision syndrome (CVS). Methods: A cross-sectional study was conducted in office workers, computer users of both sexes, with an age range of 18-45 years without comorbidities; we included 108 subjects divided into 3 groups according to the time of computer exposure in hours per day (H/D): 4 (n = 23), 4 -7.9 (n = 49), 8 (n = 39). A specific questionnaire was applied to them on the exposure time and the type of visual display terminal (VDT) used, as well as the computer vision symptoms scale (CVSS17). DED was diagnosed with the Ocular Surface Disease Index (OSDI). Ocular surface damage and signs of DED were evaluated with the tear rupture time test (TBUT), the integrity of the ocular surface by ocular surface staining (OSS) and the production of the aqueous basal tear film using the Schirmer test. Results: Average computer exposure time, measured differently, was positively correlated with DED development. The computer exposure time measured in hours per year and TBUT showed a significant negative correlation (p <0.001) (rho -0.463). Years of computer exposure and staining of the ocular surface showed a significant positive correlation (p <0 0.001; rho 0.404). The accumulated exposure time was negatively correlated with TBUT (p <0.001; rho -0.376) and positively with OSS (p <0.001; rho 0.433). Schirmer test did not correlate with computer exposure time. Conclusion: The prolonged time of exposure to the computer in subjects with CVS was significantly correlated with the DED tests, in the different ways of measuring it; but not with the Schirmer test.
引用
收藏
页码:4311 / 4317
页数:7
相关论文
共 23 条
[1]  
Abusharha AA, 2017, CLIN OPTOM, V9, P133, DOI 10.2147/OPTO.S142718
[2]  
Akinbinu T. R., 2014, J MED PRACTICE REV, V5, P20, DOI DOI 10.5897/MPR.2014.0121
[3]  
Al Rashidi SH, 2017, INT J HEALTH SCI-IJH, V11, P17
[4]  
Aronsson Gunnar, 1995, Int J Occup Saf Ergon, V1, P1, DOI 10.1080/10803548.1995.11076300
[5]  
Bali J., 2014, J Clin Ophthalmol Res, V2, P61, DOI [DOI 10.4103/23203897.122661, 10.4103/2320-3897.122661, DOI 10.4103/2320-3897.122661]
[6]   Computer vision syndrome: A review [J].
Blehm, C ;
Vishnu, S ;
Khattak, A ;
Mitra, S ;
Yee, RW .
SURVEY OF OPHTHALMOLOGY, 2005, 50 (03) :253-262
[7]   Grading of corneal and conjunctival staining in the context of other dry eye tests [J].
Bron, AJ ;
Evans, VE ;
Smith, JA .
CORNEA, 2003, 22 (07) :640-650
[8]   Reliability of 4 Clinical Grading Systems for Corneal Staining [J].
Chun, Yeoun Sook ;
Park, In Ki .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (05) :1097-1102
[9]   TFOS DEWS II Report Executive Summary [J].
Craig, Jennifer P. ;
Nelson, J. Daniel ;
Azar, Dimitri T. ;
Belmonte, Carlos ;
Bron, Anthony J. ;
Chauhan, Sunil K. ;
de Paiva, Cintia S. ;
Gomes, Jose A. P. ;
Hammitt, Katherine M. ;
Jones, Lyndon ;
Nichols, Jason J. ;
Nichols, Kelly K. ;
Novack, Gary D. ;
Stapleton, Fiona J. ;
Willcox, Mark D. P. ;
Wolffsohn, James S. ;
Sullivan, David A. .
OCULAR SURFACE, 2017, 15 (04) :802-812
[10]  
Del Rio Martinez J, 2007, TRABAJO PROLONGADO C