摘要
The surfaces of glass sensor chips were modified with dextran to generate a layer protecting the sensor surface from unspecific protein binding and also serving as a matrix for covalent protein immobilisation. Dextran was coupled to the glass surface in different concentrations either covalently on amino-functionalised glass chips or via biotin-avidin binding. Unspecific binding of BSA was monitored with the grating coupler system, and was increasingly suppressed with increasing dextran concentrations. Using a solution with 100 mg/ml carboxymethylated dextran decreased the signals to approximately 2% of those obtained at an untreated glass chip. Antibodies were successfully immobilised in the dextran and binding to the corresponding Cy5-labelled antigen was repeatedly monitored using a fluorescence sensor system (total internal reflection fluorescence (TIRF)). (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:655 / 664
页数:10
相关论文
共 39 条
[1]  
AHLUWALIA A, 1991, BIOSENS BIOELECTRON, V7, P207
[2]   Detection of sulphamethazine with an optical biosensor and anti-idiotypic antibodies [J].
Akkoyun, A ;
Kohen, VF ;
Bilitewski, U .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 70 (1-3) :12-18
[3]   REMOTE FIBER-OPTIC BIOSENSORS BASED ON EVANESCENT-EXCITED FLUORO-IMMUNOASSAY - CONCEPT AND PROGRESS [J].
ANDRADE, JD ;
VANWAGENEN, RA ;
GREGONIS, DE ;
NEWBY, K ;
LIN, JN .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 1985, 32 (07) :1175-1179
[4]   TOTAL INTERNAL-REFLECTION FLUORESCENCE [J].
AXELROD, D ;
BURGHARDT, TP ;
THOMPSON, NL .
ANNUAL REVIEW OF BIOPHYSICS AND BIOENGINEERING, 1984, 13 :247-268
[5]   Direct observation of affinity reactions by reflected-mode operation of integrated optical grating coupler [J].
Brandenburg, A ;
Polzius, R ;
Bier, F ;
Bilitewski, U ;
Wagner, E .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 30 (01) :55-59
[6]   A label-free affinity sensor with compensation of unspecific protein interaction by a highly sensitive integrated optical Mach-Zehnder interferometer on silicon [J].
Brosinger, F ;
Freimuth, H ;
Lacher, M ;
Ehrfeld, W ;
Gedig, E ;
Katerkamp, A ;
Spener, F ;
Cammann, K .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 44 (1-3) :350-355
[7]   The detection of human β2-microglobulin by grating coupler immunosensor with three dimensional antibody networks [J].
Brynda, E ;
Houska, M ;
Brandenburg, A ;
Wikerstal, A ;
Skvor, J .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (04) :363-368
[8]   Real-time analysis of avidin adsorption with an integrated-optical output grating coupler: Adsorption kinetics and optical anisotropy of adsorbed monomolecular layers [J].
Clerc, D ;
Lukosz, W .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (03) :185-194
[9]   A DIRECT SURFACE-PLASMON POLARITON IMMUNOSENSOR - PRELIMINARY INVESTIGATION OF THE NONSPECIFIC ADSORPTION OF SERUM COMPONENTS TO THE SENSOR INTERFACE [J].
CULLEN, DC ;
LOWE, CR .
SENSORS AND ACTUATORS B-CHEMICAL, 1990, 1 (1-6) :576-579
[10]  
CULLEN DC, 1987, BIOSENSORS, V3, P211